Description
1. Product Presentation
The ECG thermal paper block for the Siemens CardioStat 31 and 31S electrocardiograph is the recording consumable that guarantees clear, stable and archivable tracings on CardioStat series equipment. Its Z-fold format of 104 × 100 mm with 300 sheets per block and red grid is designed for continuous capture of electrocardiographic recordings in cardiology clinics, emergency departments, occupational medicine and diagnostic units.
Marketed under the reference Cahnos 0553078, it reproduces the construction of the original factory consumable 9390477 E100E, so it can be used as a direct replacement for the original paper. It is supplied in a box of 20 units with immediate delivery (24-72 h), as a replenishment solution that ensures the continuity of care for your service.
2. Technical explanation of the equipment and procedure
The Siemens CardioStat 31/31S electrocardiograph records the electrical activity of the heart using a direct thermal printing system: the image is generated by contact of the hot print head with the thermal-sensitive layer of the paper, without the need for ink, toner or ribbon. The quality of the tracing therefore depends on the thermal sensitivity of the paper, its grammage and the correct orientation of the block: the Z-fold format feeds the sheets continuously, making it easier to load the device and later archive the recording.
The pre-printed red grid allows the clinician to accurately measure amplitudes (mV), intervals (PR, QT, RR) and recording speeds (mm/s) directly on the paper, while the print head prints the patient signal and identification data on each tracing. The use of verified quality paper prevents jams, ghost prints and premature fading of the image in the clinical record.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Compatible equipment model | Siemens CardioStat 31 and 31S (electrocardiograph with thermal recorder) |
| Manufacturer OEM reference | 9390477 E100E |
| SKU / Commercial reference Cahnos | 0553078 · line code 7754 (internal, not manufacturer code) |
| Block dimensions | 104 mm × 100 mm |
| Capacity | 300 sheets per block |
| Grid colour | Red |
| Format | Z-fold thermal paper (block) |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 units (pads) |
| Application | Electrocardiographic (ECG) and medical recording on equipment with a thermal printhead compatible with its grammage |
| Classification | Class I medical device (recording paper with measuring function) · CE · Royal Decree 1591/2009 · Directives 93/42/EEC and 2007/47/EC |
| Trace preservation | Approx. 5 years after printing, under normal archival conditions |
| Recommended storage | Cool, dry place, 5 °C – 40 °C, protected from direct sunlight |
4. Equivalences and Cross-References
The OEM reference 9390477 for the paper for Siemens CardioStat 31/31S is consistently documented by European manufacturers and distributors of medical recording paper (Diagramm Halbach, megro, Rennecke Medic), with Z-fold format of 104 × 100 mm × 300 sheets and EAN 4250123601028. The following equivalences should be understood as functional comparisons confirmed in manufacturer and authorised distribution catalogues, not as an official equivalence table published by the equipment manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Siemens Healthineers (original code) | ECG recording paper CardioStat 31/31S · 104 × 100 mm · 300 sheets · Z-fold | 9390477 E100E (EAN 4250123601028) | Exact reference equivalence (original manufacturer code) | OEM code confirmed in authorised distribution sources (Rennecke Medic / megro: EKG-9390477; EAN 4250123601028). Same dimensions (104 × 100 mm), 300 sheets and red grid. Check presentation and batch against the box of 20 units of this reference. |
| LESSA / AB Medica Group (Spain) | Z-fold paper SIEMENS CARDIOSTAT-31/31S · 104 × 100 × 300 · red grid | 29.104.00 (SKU 2910400; OEM 93.90.477) | Comparable by category (not interchangeable 1:1) | Same dimensions (104 × 100 mm), 300 sheets, Z-fold format and red grid; the same construction is also documented as NT-2910400 (Neotecnia). Verify grammage and thermal sensitivity against the device data sheet. |
| Diagramm Halbach GmbH & Co. KG (Germany) | ECG paper Siemens Cardiostat 31/31S · 104 × 100 mm · 10 × 300 sheets | 711855 | Comparable by category (not interchangeable 1:1) | CE certified medical recording paper for CardioStat 31/31S, Z-fold, 300 sheets per block and red grid. Verify grammage and thermal sensitivity against the device data sheet. |
There is no equivalence table validated by the equipment manufacturer for this reference; consult the technical department before use in tenders. The code 7754 accompanying the reference is an internal distribution line code and must not be used as a manufacturer code: the code identifying the consumable is OEM 9390477 (E100E), confirmed in authorised distribution sources.
5. Selection tips and variants of interest
Select this block when your service uses a Siemens CardioStat 31 or 31S electrocardiograph: always check the sheet width (104 mm), height (100 mm), number of sheets (300), grid colour (red) and Z-fold format before replacing the consumable; an incorrect grid or grammage can affect the legibility of the recording and wear on the thermal print head.
Within the same CardioStat 31/31S family, the Cahnos catalogue offers other variants: the 104 × 100 mm block with 200 sheets of the same OEM 9390477 (ref. 10588) and the 104 mm × 30 m roll with red grid for the same machine (ref. 0553103, OEM 93.90.766 / 15078). In the Siemens family you will also find the block for CARDIOSTAT 3 of 144 × 150 mm with 400 sheets and orange grid (ref. 0553209) or the SICARD 460 block of 148 × 100 mm with 400 sheets (ref. 0553113).
Store the paper in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve tracing stability and prevent fogging of the thermal-sensitive layer. Recording expiry: approximately 5 years under suitable storage conditions. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.