Description
1. Product Presentation
Ensure the continuity of care in your cardiology service with the block of ECG thermal paper 120×100 mm × 300 sheets with blue grid for the Cardioline Cardiette AR 1200 ADV / AR 1200 VIEW electrocardiographs from the Elettronica Trentina family (Cardiette range). Its Z-fold (fanfold) format ensures continuous and orderly feeding, without jams, and a crisp, stable and perfectly measurable electrocardiographic recording on every examination, whether in the cardiology clinic, emergency department, primary care or stress test units. It is supplied in a box of 10 blocks for planned and cost-effective replenishment, with delivery in 24-72 h and special terms for institutional purchases and tenders.
2. What this consumable is and how it works
This block uses direct thermal printing technology: the electrocardiograph’s thermal printhead transfers heat to the heat-sensitive layer of the paper and generates the trace instantly, without the need for ink, toner or ribbon, which reduces equipment maintenance and allows the clinical document to be obtained immediately after each test. The Z-fold format is placed directly in the recorder tray: each sheet is pre-folded (120×100 mm) to feed continuously, avoiding jams and speeding up replenishment. The pre-printed blue grid acts as a millimetric measurement reference on the paper itself: it allows assessment of wave amplitude (mV), interval duration (PR, QT, RR) and recording speeds (mm/s), facilitating clinical interpretation of the ECG and its subsequent filing in the patient’s medical record. The advance marker synchronises sheet cutting on each recording.
3. Technical Specifications
| Compatible models | Cardioline Cardiette AR 1200 ADV / AR 1200 VIEW (Cardiette family · Elettronica Trentina) |
| Reference Cahnos (SKU) | 0553005-CL |
| Paper factory reference | 29.120.06 (shared construction with Lessa catalogue 2912006; check grid colour on the batch label) |
| OEM code associated with the format | 66010039 (associated by Modul USA, megro and Lessa with the 120×100×300 pack; 66010033 corresponds to the 120×20 m roll) |
| Distribution line code | 12464 (internal code; do not use as manufacturer reference) |
| Sheet dimensions | 120 mm × 100 mm |
| Number of sheets | 300 sheets per block |
| Grid colour | Blue (millimetric measurement reference) |
| Format | Z-fold (fanfold) pad with advance marker |
| Paper type | High-sensitivity thermal paper for thermal printhead (Quicktrace HS type range) |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 10 blocks |
| Application | Medical recording: resting electrocardiography (ECG), stress tests and cardiac tracings |
| Regulatory classification | Class I medical device (with measuring function) · RD 1591/2009 · Directives 93/42/EEC and 2007/47/EC; verify CE marking of the batch |
| Trace shelf life | Approx. 5 years after printing under proper storage conditions |
| Storage | Cool, dry place (5–40 °C), away from direct sunlight and excessive humidity |
4. Equivalences and Cross-References
The 120×100 mm × 300-sheet format with blue grid and Z-fold is a widely used standard in the Elettronica Trentina / Cardiette / Cardioline range for the AR 1200 ADV / AR 1200 VIEW models. There is no official equivalence table published by the equipment manufacturer cross-referencing this consumable with other brands; the following references share the physical format dimension by dimension (measurements, sheets, blue grid and advance marker) and have been verified in public catalogues of their respective manufacturers or authorised distributors. They are classified as comparable by category and not 1:1 interchangeable, and must be validated with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Elettronica Trentina (same equipment manufacturer) | Cardiette AR1200 paper – z-fold 120×100×300 (OEM 66010039) | 66010039 | Exact reference equivalence (same manufacturer) | OEM code of the consumable itself for the 120×100×300 format for AR 1200 ADV; confirmed in paper manufacturer catalogues (Lessa, declared OEM 66010039) and distribution (Modul USA, megro GmbH). |
| LESSA / AB Medica Group (Spain) | Cardiette AR1200 folded paper pack, 120×100×300 (OEM 66010039) | 29.120.06 (Lessa catalogue 2912006 · SKU 300240) | Comparable by category (not interchangeable 1:1) | Same dimensions 120×100×300 and same OEM; the official Lessa catalogue documents this numbering with a RED grid (as opposed to the blue one of this reference) and a declared readability of 12 years. Verify grid colour on the batch before replacing. |
| GIMA S.p.A. (Italy) | ECG thermal paper 120×100 mm × 300, blue grid – compatible ELETTRONICA TRENTINA / CARDIETTE / CARDIOLINE AR 1200 (View/Adv) | 32978 (also CR32978; packaging: 10 packs) | Comparable by category (not interchangeable 1:1) | Same measurements, sheets, blue grid and advance indicators; confirmed in the official datasheet and by authorised distributors. Heat-sensitive coating not confirmed as equivalent to the original. |
| EasyTrace® / DEAS S.r.l. (Italy) via Modul USA | ECG Paper Z-fold Packs for ET Medical Devices Cardiette AR1200ADV (model 66010039) | ET120100PA1 | Comparable by category (not interchangeable 1:1) | Format 120×100×300 and original code 66010039 declared; presentation of 20 units per box compared to the box of 10 for this reference. Confirmed in the manufacturer’s catalogue. |
| Quality Chart Paper (USA) | CARDIETTE AR1200 Z-fold (original code 660010039C), 120×100×300 | ET120100PA1MU | Comparable by category (not interchangeable 1:1) | Same measurements and Z-fold format, 10 packs per box; grid not declared in the source (verify batch). Confirmed on the manufacturer’s website. |
| megro GmbH (Germany) | Cardiette EKG-Papier AR 1200, 120 mm × 100 mm (300 sheets), box of 10 blocks | EKG 66010039 | Comparable by category (not interchangeable 1:1) | Same measurements, sheets and OEM 66010039; confirmed in the manufacturer’s catalogue. Grid colour not declared in the source; verify batch. |
| FIDIM (repackaged, Italy) | Thermal chart 120×100×300 FF for CARDIOLINE AR-1200 (view/adv), blue grid | CRCFET005 | Comparable by category (not interchangeable 1:1) | Same dimensions 120×100×300 and blue grid; own code of the repacker, without official validation from the equipment manufacturer; verify grammage and sensitivity against the printhead before replacing. Confirmed by authorised distributors. |
| DH Medical (authorised distributor) | ECG paper AR 1200 (View/Adv) 120×100×300, box of 10 packs, blue grid | 400132978 | Comparable by category (not interchangeable 1:1) | Same measurements, sheets, blue grid and marker; distributor’s own SKU, declared as a Class I medical device. Same construction as this reference. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The code 12464 accompanying this reference is an internal distribution line code and must not be used as a manufacturer code: the reference identifying this consumable is Cahnos 0553005-CL and the factory construction is 29.120.06, associated by paper catalogues with the 120×100×300 format (OEM 66010039).
5. Selection tips and variants of interest
Before reordering, check three details on your electrocardiograph: the paper width (120 mm), the loading format (Z-fold block or roll) and the grid colour you prefer for interpreting the traces (blue in this reference). Locate reference 29.120.06 or OEM 66010039 on the block label or in the device manual to confirm exact compatibility with the AR 1200 ADV / AR 1200 VIEW models. Do not confuse this block with the 120 mm × 20 m roll from the same family (refs. Cahnos 0553151-CL / 0553151-ET) nor with the 60×75 mm × 250-sheet block for the AR 600 series (ref. 0553005-ET); nor with the 50 mm × 15 m roll from the Microruler / Replay 50 family (ref. 0553004), which is for a different, non-interchangeable device. Store the block in a cool, dry place away from direct sunlight (5–40 °C), protected from humidity and heat sources, to preserve the sensitivity of the thermochromic layer and prevent trace fogging during record storage. For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and a formal quotation under B2B volume conditions.




Reviews
There are no reviews yet.