Description
1. Commercial Introduction
The ECG thermal paper pad for the Schiller CARDIOVIT AT-3 / AT-3 C 3.5 (Cahnos reference 0553045) is the recording consumable that keeps your electrocardiograph operational in cardiology clinics, emergency departments, occupational medicine and diagnostic centres. Its Z-fold format of 70 × 100 mm, with 200 sheets per pad and a green grid, guarantees clear, stable and perfectly measurable traces in every examination, both in resting ECG and in stress tests.
The box presentation of 20 pads allows planned and cost-effective replenishment, avoiding service interruptions due to lack of consumables. Manufacturer (OEM) reference: 2,157,007. Available with delivery in 24-72 h; request a formal quotation for institutional orders, maintenance contracts and tenders.
2. Technical Explanation
This pad uses direct thermal printing technology: the electrocardiograph’s thermal printhead transfers heat to the heat-sensitive layer of the paper and produces the trace instantly, without the need for ink, toner or ribbon, which reduces recorder maintenance and speeds up the output of the clinical document. The high-sensitivity thermal paper is sized to the grammage required by the equipment, ensuring a trace with no blank areas or saturation.
The pre-printed green grid acts as a measurement reference (recording graph paper): it allows the amplitude of the waves (mV), the duration of the intervals (time) and the recording speeds (mm/s) to be assessed, facilitating clinical interpretation of the electrocardiogram. The pad includes an automation mark (black mark/sensor) so that the equipment synchronises events and annotations on the recording, and is presented in Z-fold (fanfold) format with a multi-perforated easy-tear separator, a format that facilitates continuous feeding, prevents jams and allows subsequent filing of the clinical document.
Main applications: resting and stress electrocardiograms (ECG), stress testing and ergometry, and other medical recordings with thermal printhead printing suitable for its grammage.
3. Technical Specifications
| Characteristic | Technical data |
| Reference Cahnos (SKU) | 0553045 |
| Equipment model | Schiller CARDIOVIT AT-3 / AT-3 C 3.5 (also cited for TM7 printers in distribution catalogues) |
| Manufacturer reference (OEM) | 2,157,007 (US numbering in distribution: 2,157,007A / 2157-007A) |
| Sheet dimensions | 70 mm × 100 mm |
| Number of sheets | 200 per block |
| Equivalent length | ≈ 20 m per pad (200 sheets × 100 mm; calculated distribution data) |
| Format | Z-fold thermal paper block (fanfold) |
| Grid colour | Green |
| Marker / automation mark | Yes (black mark; check batch) |
| Paper type | High-sensitivity thermal for thermal printhead printing |
| Print technology | Direct thermal (without ink, toner or ribbon) |
| Commercial presentation | Box of 20 blocks |
| Regulatory classification | Medical device Class I (with measuring function) · R.D. 1591/2009 · European Directives 93/42/EEC and 2007/47/EC |
| Trace shelf life | 5 years after printing (refer to the product instructions) |
| Storage | Cool, dry place, 5 °C to 40 °C, away from direct sunlight and excessive humidity |
4. Equivalences and Cross-References
Preliminary note: there is no equivalence table validated by the manufacturer (Schiller) that authorises third-party consumables for this pad. The OEM reference associated with the equipment is 2,157,007 (CARDIOVIT AT-3 / AT-3 C 3.5), consistently confirmed in authorised distribution catalogues, recording paper manufacturers and distribution databases (also cited as 2,157,007A / 2157-007A in US numbering). References from other brands belong to the same category (Z-fold ECG thermal paper of 70 × 100 mm × 200 sheets with grid) and have been cross-checked in public catalogues of their respective manufacturers or authorised distributors. Before substituting in a tender, verify one by one the number of sheets, the grid colour and the automation mark.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Schiller (same manufacturer) | CARDIOVIT AT-3 / AT-3 C 3.5 (OEM paper reproduced by this pad) | 2,157,007 · 2,157,007A | Exact reference equivalence (same manufacturer) | OEM reference of the product itself: 70 × 100 mm × 200 sheets, green grid, Z-fold. Confirmed in authorised distribution catalogues (check box presentation according to batch). |
| EasyTrace® (Deas S.r.l., Italy) | Z-fold ECG paper for Schiller AT-3 / TM7 | SH70100P | Comparable by category (not interchangeable 1:1) | Confirmed in the manufacturer’s official catalogue: 70 × 100 mm × 200 sheets, declared equivalent to original 2157007, 20 units per box. Check the grid colour of the batch. |
| Leonhard Lang (US) | Recording Chart Paper Schiller 2157-007A (AT-3) | 2157-007A | Comparable by category (not interchangeable 1:1) | Confirmed in the official catalogue and authorised distribution listings: 70 × 100 mm, 200 sheets, green grid in the European version; box presentation of 100 pads (compared with 20). |
| Nissha Medical / Welch Allyn (USA) | Schiller ECG Paper z-fold for AT-3 / AT-3 C | SCS-EKG-2157-007A | Comparable by category (not interchangeable 1:1) | Confirmed at authorised distributors (Davis Medical / Probo Medical): 70 × 100 mm × 200 sheets, boxes of 10 packs. Check the grid colour of the batch. |
| FIDIM | ECG pack Schiller AT/3 70×100×200 FF | CRCMSC002 | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution: same dimensions 70 × 100 × 200 sheets, declared for Schiller AT/3. Check grid colour and marker before substituting. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in a tender. The OEM reference associated with this pad is 2,157,007 (Schiller CARDIOVIT AT-3 / AT-3 C 3.5) and the same physical format 70 × 100 × 200 is distributed on the market under each paper manufacturer’s own numbering (EasyTrace SH70100P, Leonhard Lang 2157-007A, FIDIM CRCMSC002, Quality Chart Paper SH70100PA1), in green, red or other grid versions; always check the grid colour, number of sheets and box presentation before substitution.
5. Selection tips and variants of interest
Check the exact model of your equipment: this pad is designed for Schiller CARDIOVIT AT-3 / AT-3 C 3.5 (70 × 100 × 200 sheets, green grid, including the TM7 printer mentioned in distribution). Do not confuse it with pads from other CARDIOVIT series: AT-4 / AT-104 (90 × 90 × 266, ref. 2,157,016 / 290018, red grid), AT-1 / Spirovit SP-1 (90 × 90 × 400, ref. 2,157,014 / 290017, red grid), AT-6 / AT-6 M (145 × 100 × 350, ref. 2,157,005, green grid) or AT-101 / Defigard (80 × 70, ref. 2,157,026 / 290026, red grid), which share the family but differ in dimensions, number of sheets and grid colour.
Grid and marker colour: the AT-3 unit uses paper with a green grid and an automation mark (black mark). Versions of the same format with a red grid (common in US distribution, e.g. Beck-Lee, with 175 sheets) are not interchangeable without prior verification on each unit.
Do not confuse a pad with a roll: if your recorder prints on a roll, select the corresponding roll reference from our family of thermal papers for Schiller equipment instead of this pad.
Variants of the same family at Cahnos (Schiller papers): 0553167 (AT-6 / AT-6 M, 145 × 100 × 350), 0553059 (AT-1 / SP-1, 90 × 90 × 400), 0553121 (AT-4 / AT-104, 90 × 90 × 266), 0992026-S (AT-101 / Defigard, 80 × 70 × 314), 0553168-S (AT-2 / CS 200, 210 × 280) and 0553077 (AT-10 / AT-60 / CS 100, 210 × 280).
Storage: keep the pad in a cool, dry place away from direct sunlight, at a stable temperature between 5 °C and 40 °C, to preserve the quality of the trace and prevent fogging of the thermal layer during the 5-year retention period of the clinical record.


Reviews
There are no reviews yet.