We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

ECG thermal paper roll Mortara Rangoni ELI 100 · 108 mm × 23 m · Red grid · OEM 00310801 / 9100-016-50 · Ref. 0553175-MR · Box of 20 units

28,16 €

ECG thermal paper roll for Mortara Rangoni ELI 100 electrocardiograph, in 108 mm × 23 m format with high-contrast red grid and Quicktrace® HS thermal quality. Direct thermal printing by printhead, without ink or toner, with sharp and stable trace suitable for clinical archive (recording durability: 5 years). Covers the equipment OEM references 00310801 and 9100-016-50 and shares format with GE-Marquette 9402-023 and Physio-Control 805319 papers (MAC PC and LIFEPAK 11/12/15). Presentation in box of 20 units (ref. 0553175-MR), with 24-72 h delivery.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0553175-MR

Description

1. Introduction: the recording consumable for your Mortara ELI 100 electrocardiograph

The Mortara Rangoni ECG thermal paper roll (ref. Cahnos 0553175-MR) is the reference recording consumable for the electrocardiographs of the Mortara Rangoni ELI 100 family. Its 108 mm × 23 m format with red millimetre grid guarantees sharp, stable and perfectly measurable traces in every examination, ensuring continuity of care and correct clinical documentation of the patient. It is a reliable spare part, with permanent stock and immediate dispatch, designed for cardiology practices, emergency departments, occupational medicine and centres that cannot afford service interruptions due to lack of paper.

2. Technical explanation: thermal printing and ECG recording

This roll uses direct thermal printing technology: the electrocardiograph’s thermal head transfers heat to the paper’s thermosensitive layer and generates the trace instantly, without the need for ink, toner or ribbon. The pre-printed red grid acts as a measurement reference (amplitude of the leads, recording speed and measurement of segments and intervals), essential for the correct interpretation of the electrocardiogram. The paper is formulated with Quicktrace® HS thermosensitive quality, suitable for the grammage required by the printhead system of these devices. For proper operation, the roll must be stored protected from direct sunlight and humidity, at a stable temperature between 5 °C and 40 °C; the durability of the printed trace is 5 years if properly preserved.

3. Technical Specifications

Compatible equipment model Mortara Rangoni ELI 100 (roll format 108 mm × 23 m)
SKU / Reference Cahnos 0553175-MR
Paper factory reference 10.108.00
Roll dimensions 108 mm × 23 m
Inner diameter of the core 16 mm (external winding)
Grid colour Red
Presentation Box of 20 units
Cited OEM reference 00310801 (OEM numbering of the device, pending independent verification) · 9100-016-50 (OEM Mortara ELI 100)
Paper type High-sensitivity thermal paper (Quicktrace® HS quality)
Print technology Direct thermal by printhead (no ink or toner)
Application Medical recording: electrocardiography (ECG), stress testing and monitoring with thermal printing
Regulatory classification Medical device Class I (with measuring function) · R.D. 1591/2009 · European Directives 93/42/EEC and 2007/47/EC
Trace shelf life 5 years after printing (under adequate storage conditions)
Storage Cool, dry place, away from direct sunlight, stable temperature between 5 °C and 40 °C

Equipment compatibility (same roll format 108 mm × 23 m, red grid):

Brand / Equipment family Commonly used models Observations
Mortara Rangoni ELI 100 Reference format of this datasheet (OEM 00310801 / 9100-016-50).
GE HealthCare / Marquette / Hellige MAC PC Common market use with the original GE-Marquette 9402-023 paper.
Physio-Control (Stryker) LIFEPAK 11 / 12 / 15 Common market use with the original paper P/N 805319.
Compumed 507 Common market use; verify permissible width before replacing.

Note: compatibility with devices other than the Mortara ELI 100 corresponds to common market uses with this roll format and must always be confirmed with the device datasheet before a replacement or tender.

4. Equivalences and Cross-References

The 108 mm × 23 m format with red grid is shared by the Mortara ELI 100, GE/Marquette MAC PC and Physio-Control LIFEPAK 11/12/15 electrocardiographs. The original GE-Marquette device reference 9402-023 is confirmed in the GUDID/FDA regulatory database (model Vermed MQE 9402-023, catalogue 01248749, declared manufacturer Graphic Controls Acquisition Corp; electrocardiographic recording paper, Class I). Below are detailed verified references of the same roll format:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Mortara (device OEM) ELI 100 thermal paper (108 mm × 23 m, red grid) 9100-016-50 Comparable by category (not interchangeable 1:1) OEM reference of the device itself for ELI 100 in identical format (108 mm × 23 m, red grid), verified in the master recording paper catalogue. Confirm number of rolls per box.
GE HealthCare (original) GE-Marquette MAC PC (paper 9402-023) 9402-023 Comparable by category (not interchangeable 1:1) Original device reference for 108 mm × 23 m roll, red grid, for use in MAC PC; also declared as commonly used in Mortara ELI 100 and Compumed 507. Consistently confirmed across multiple distributors and in GUDID.
Vermed / Graphic Controls MQE 9402-023 (ECG recording paper) 01248749 Comparable by category (not interchangeable 1:1) Same ECG roll format verified in GUDID/FDA (Class I, electrocardiographic recording paper). Verify batch, grammage and number of rolls per box before replacing.
Physio-Control / Stryker (equipment OEM) LIFEPAK 11 / 15 ECG paper 805319 Comparable by category (not interchangeable 1:1) Original device reference for 108 mm × 23 m roll, red grid, consistently verified in the master recording paper catalogue. Confirm box presentation.
Danlee Medical (distributor) Compatible Red Grid Chart Paper 9402-023 PM9402023 Comparable by category (not interchangeable 1:1) Red grid compatible paper for MAC PC, Mortara ELI 100 and Compumed 507, advertised as equivalent to 9402-023. Distributor catalogue code; verify presentation.

Note on references: the OEM code 00310801 accompanying the model comes from the device numbering and could not be independently verified in public sources; the codes 8901, 9472-006 and 2009828-023 circulating in some datasheets have also not been able to be verified in official sources and must be confirmed with the manufacturer before use in a tender. There is no manufacturer-validated equivalence table; consult the technical department before using in a tender. Always verify grid width, grammage and number of rolls per box before a replacement.

5. Selection tips and variants of interest

Check the exact model of the equipment: this 108 mm × 23 m roll is the one for the Mortara Rangoni ELI 100 electrocardiograph. It is also commonly used in equipment of equivalent format such as GE/Marquette MAC PC, Physio-Control LIFEPAK 11/12/15 and Compumed 507, but always confirm the paper width accepted by your printer and the required grid colour (red in this reference).

Check the printing format: your equipment must use thermal paper in roll with red grid; a width of 108 mm is essential to avoid jams or interruptions in the recording.

Presentation: this reference is supplied in a box of 20 rolls, ideal for departments with high recording volume. For mixed equipment fleets, in the Cahnos catalogue you will find other variants of the same Mortara family: roll for ELI 100 in 108 mm × 23 m format (ref. 0992824, same OEM 9100-016-50), Z-fold pack for ELI 210/250/350 (ref. 0992016), 215 × 280 mm pack for ELI 250 i / ELI 350 (ref. 0553200), roll for ELI 230 (ref. 0553499) and compact pack for ELI 50 / 50 i (ref. 0553013-MR). Consult our technical-commercial department which recording paper reference corresponds to each electrocardiograph before placing the order.

Storage: keep the roll in a cool, dry place away from direct sunlight (5-40 °C) to preserve the thermal quality and prevent fogging of the heat-sensitive layer; do not fold the recording on the printed side once the trace has been produced to ensure its durability in the clinical archive.

Additional information

Manufacturer reference

10.108.00

OEM equipment references

Mortara 00310801 / 9100-016-50 · GE-Marquette 9402-023 · Physio-Control 805319

Compatibility

Mortara Rangoni ELI 100; commonly used in GE/Marquette/Hellige MAC PC, Physio-Control LIFEPAK 11/12/15, Compumed 507

Measurements

108 mm × 23 m

Core inner diameter

16 mm (external winding)

Grid colour

Red

Paper type

High-sensitivity thermal (Quicktrace® HS)

Printing system

Direct thermal by printhead (no ink or toner)

Presentation

Box of 20 units

Classification

Medical device Class I (with measuring function) · CE · R.D. 1591/2009

Shelf life

5 years after printing

Storage

Cool, dry place (5–40 °C), away from direct sunlight and excessive humidity

OEM equipment reference

00310801 (pending independent verification)

Compatible equipment model

Mortara Rangoni ELI 100 (format shared with GE/Marquette MAC PC and Compumed 507)

Roll dimensions

108 mm × 23 m

Application

Electrocardiography (ECG), stress testing and monitoring with thermal recording

Regulatory classification

Medical device Class I (with measuring function) · R.D. 1591/2009 · CE

Reviews

There are no reviews yet.

Be the first to review “ECG thermal paper roll Mortara Rangoni ELI 100 · 108 mm × 23 m · Red grid · OEM 00310801 / 9100-016-50 · Ref. 0553175-MR · Box of 20 units”

Your email address will not be published. Required fields are marked *