Description
1. Commercial Introduction
The ECG thermal paper block reference 0553057 is the recording consumable that keeps the GE / Hellige / Marquette MAC 800 electrocardiograph operational in cardiology departments, ECG clinics, intensive care units and diagnostic centres. Its Z-fold format of 110×140 mm with 200 sheets per block and red grid is designed for resting electrocardiographic recording, and reproduces the construction of the original equipment reference 2036970-001, ensuring equivalent paper behaviour in the recorder. The presentation in a box of 20 blocks allows planned and cost-effective replenishment. Available with delivery in 24/72 h; request a formal quotation for institutional orders and tenders.
2. Technical explanation of the equipment
The GE / Hellige / Marquette MAC 800 electrocardiograph records on thermochemical paper: the image is generated by contact of the thermal printhead on the heat-sensitive layer of the paper, without the need for ink, toner or ribbon. The pre-printed red grid acts as a measurement reference (amplitude, recording speed and segments) and is essential for the correct interpretation of the electrocardiogram. The Z-fold format with perforated sheets facilitates continuous paper feeding, prevents jams in the recorder and allows subsequent archiving of the trace in the clinical record. The grammage and thermal sensitivity are adjusted to the printhead of this equipment to guarantee sharp, stable and durable traces, preserving the integrity of the clinical document.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference Cahnos (SKU) | 0553057 |
| Model | MAC 800 |
| Original equipment reference (OEM) | GE 2036970-001 · Vyaire 2036970-001 (McKesson 1124121) |
| Paper factory reference | 29.110.10 |
| Line / distribution reference | 15191 (internal code; do not use as manufacturer reference) |
| Compatible equipment | General Electric / Hellige / Marquette MAC 800 electrocardiographs (resting ECG system) |
| Sheet dimensions | 110 mm (width) × 140 mm (length) |
| Number of sheets | 200 per block (check the batch label) |
| Format | Z-fold block with perforated sheets |
| Grid colour | Red |
| Paper type | High-sensitivity thermal paper (Quicktrace® HS quality) |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 blocks |
| Regulatory classification | Class I medical device (with measuring function) · CE · R.D. 1591/2009 · European Directives 93/42/EEC and 2007/47/EC |
| Trace shelf life | 5 years after printing under proper storage conditions |
| Storage | Cool, dry place, stable temperature between 5 °C and 40 °C; avoid direct sunlight and excessive humidity |
Verification note: the original equipment reference 2036970-001 is usually marketed with 200 sheets per block in both European and American distribution; the paper manufacturer’s master catalogue documents this same reference (29.110.10) with 150 sheets in 110×140 format. Check the batch label, the number of sheets per block and the grid colour before replacement.
4. Equivalences and Cross-References
Reference 2036970-001 is confirmed as the original equipment code for the 110×140 mm format with red grid and Z-fold of the GE / Hellige / Marquette MAC 800 electrocardiograph, in authorised European and American distribution catalogues (Davis Medical, Integris, CNA Medical, Vyaire/Sun Med with McKesson 1124121). It does not appear in the GUDID/FDA regulatory database (0 results). There is no official equivalence table published by GE HealthCare authorising third-party consumables; the following references are offered as verified comparisons and must be confirmed with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GE HealthCare (original equipment) | ECG thermal recording paper z-fold for MAC 800 · 110×140 mm · red grid | 2036970-001 | Comparable by category (not interchangeable 1:1) | Original equipment reference consistently confirmed across multiple distributors (Davis Medical, Integris, CNA Medical) and in the Vyaire/Sun Med brand (McKesson 1124121): 110×140 mm, 200 sheets per pack, 10 packs per box, red grid. Not listed in GUDID/FDA. Our block reproduces this construction; check the header and grammage of the batch. |
| Paper factory reference (manufacturer’s master catalogue) | ECG Paper MAC 800 · 110×140 · red grid (OEM 2036970-001) | 29.110.10 | Exact reference equivalence | Same product: 110×140 mm format, red grid and OEM 2036970-001. This is the factory reference for this pad, documented in the paper manufacturer’s master catalogue; it corresponds to reference Cahnos 0553057. |
| EasyTrace® (Deas S.r.l., Italy) · Modul USA | ECG Paper Z-fold for Marquette / Hellige MAC 800 (ORIGINAL REF 2036970-001) | HE110140P | Comparable by category (not interchangeable 1:1) | Verified in manufacturer listings and authorised distribution (and official stores): 110×140 mm × 200 sheets, red grid, original ref. 2036970-001, BPA-free, made in Italy. Confirm number of pads per box and grid colour of the batch. |
| Diagramm Halbach GmbH & Co. KG (Germany) | Hellige ECG paper Mac 800 · 110×140 mm · 200 sheets | EKG 2036970-001 | Comparable by category (not interchangeable 1:1) | Verified in the official store and its distribution network: 110×140 mm × 200 sheets, Z-fold, carton of 10 pads, manufacturer Diagramm Halbach, GTIN 4250123602445. Confirm grid colour and grammage before replacing. |
There is no equivalence table validated by the equipment manufacturer (GE HealthCare) that authorises third-party consumables for reference 2036970-001; consult the technical department before using in a tender. Always verify the sheet width (110 mm), grid colour (red), number of sheets per pad (150/200 according to catalogue) and grammage of the batch received before formalising the replacement. The code 15191 accompanying the reference is an internal factory line code and should not be used as a manufacturer code: the reference identifying the consumable is OEM 2036970-001 and the paper factory reference is 29.110.10.
5. Selection tips and variants of interest
- Verify the exact model of the equipment: this 110×140 mm pad is the one indicated for the GE / Hellige / Marquette MAC 800 electrocardiograph (OEM 2036970-001), resting ECG system. Always confirm the sheet width admissible by your recorder, the Z-fold format and the grid colour before replacing the consumable; an inadequate grammage or grid can affect the readability of the recording and the wear of the thermal head.
- Do not confuse it with other formats in the family: GE / Hellige / Marquette electrocardiographs use different dimensions depending on the model: roll of 108 mm × 23 m for MAC PC (ref. 0553175-EH), Z-fold pad of 80×90×280 for MAC 400 / MAC 600 (ref. 0992027), pad of 90×90×360 for Microsmart / MAC 500 (ref. 0553064), pad of 210×280×300 for CASE / MAC 6-15 / 5000 / 5500 / 3500 / 8000 (ref. 0553162) and pad of 210×295×150 for Cardiosmart / MAC 1200 (ref. 0553066). They are not interchangeable without prior verification.
- Packaging options: this reference is supplied in a box of 20 pads in our catalogue; in the US market the original GE 2036970-001 is normally sold in boxes of 10 packages. Always compare the price per sheet and the number of packages per box.
- Storage: store the pads in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the thermosensitive layer and avoid trace fogging. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.