Description
1. Thermal paper roll for the Esaote MCR II defibrillator
This thermal paper roll is the recording consumable recommended for the Esaote Biomedica MCR II defibrillator, the device that ensures printed documentation of events and traces during patient care. With a format of 50 mm wide by 20 metres long, it guarantees full compatibility with OEM number 9690018000 and delivers sharp, stable, high-contrast prints, essential for clinical recording and archiving of the care episode.
It is supplied in a box of 20 units, a presentation designed for emergency departments, critical care units, ambulances and centres with continuous external defibrillation activity, so that the device never runs out of paper at the critical moment. Available with delivery in 24-72 h.
2. Technical Explanation
The thermal paper reacts to heat: the image is generated as the paper passes through the thermal print head of the defibrillator printer, which darkens the heat-sensitive layer at the points of contact. This direct printing system completely eliminates the use of ink, toner or ribbon, reduces equipment maintenance and provides immediate output speed, something critical when the record must be printed without interrupting patient care.
Printing on this roll is guaranteed to maintain its integrity and legibility for 12 years, meeting the strict requirements for long-term archiving and storage of medical records. It is a white roll without printed grid (BLANK format), specific to the MCR II printer; it must be stored protected from direct sunlight and humidity, at a stable temperature between 5 °C and 40 °C, to prevent fogging of the heat-sensitive layer and preserve the quality of the trace.
3. Technical Specifications
Main features of the recording roll for the Esaote MCR II defibrillator:
| Characteristic | Specification |
|---|---|
| Brand / family | Esaote Biomedica (original equipment; recording consumable) |
| Compatible model | MCR II defibrillator (also OTE Biomedica family of the same group) |
| Manufacturer OEM reference | 9690018000 |
| Line references | 0553189 · 10.050.11 · 8615 |
| Factory reference | 10.050.11 (LESSA / AB Medica Group) · cat. LESSA 1005011 |
| Roll dimensions | 50 mm (width) × 20 m (length) |
| Colour / grid | White, without grid (BLANK format) |
| Paper type | Thermosensitive thermal paper for medical recording (Quicktrace® HS quality) |
| Printing system | Direct thermal by printhead (no ink or toner) |
| Application | Trace and event recording on MCR II defibrillator/monitor |
| Trace durability | Guaranteed 12-year legibility for clinical archiving |
| Presentation | Box of 20 units |
| Classification | Class I medical device · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC · CE |
| Reference Cahnos | 0553189 |
| Storage | Cool, dry and dark place; 5-40 °C, away from direct sunlight |
4. Equivalences and Cross-References
The original reference identifying this consumable for the MCR II defibrillator is the OEM code 9690018000 from Esaote Biomedica. The paper is manufactured by LESSA / AB Medica Group (factory reference 10.050.11, catalogue 1005011), confirmed in the manufacturer’s catalogue and on its official website with the same OEM, dimensions 50×20 m, white colour without grid and 12-year legibility. Other references listed below have been checked against official catalogues or authorised distribution sources; differences in equipment, length or presentation prevent them from being considered interchangeable 1:1 without prior verification on each unit.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| LESSA / AB Medica Group | Thermal paper roll for Esaote MCR II (OEM 9690018000) | 10.050.11 (cat. LESSA 1005011) | Exact reference equivalence | Same product: 50×20 m, white without grid (BLANK), declared legibility of 12 years. It is the factory reference of the roll marketed as 0553189, confirmed in the manufacturer’s catalogue and on the LESSA official website. |
| Philips Healthcare | Efficia 50 mm thermal paper, roll without lines (Efficia CM100 / DFM100) | 989803190381 | Comparable by category (not interchangeable 1:1) | Same dimensions 50 × 20 m and white without lines, confirmed in the official Philips catalogue (Philips UK shop); it is the consumable for the Efficia DFM100 monitor/defibrillator, not validated for the MCR II. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Rolls of 50 × 30 m exist on the market for the same MCR-II defibrillator (specialist distributors and OTE Biomedica / Esaote family), but with a different length (30 m versus 20 m): they are not interchangeable 1:1 without checking the paper compartment and the device’s consumption. Code 8615 is an internal distribution line reference and must not be used as a manufacturer reference.
5. Selection tips and variants of interest
Always check the format before replacing: width of 50 mm, length of 20 m and white colour without grid are the three parameters that define this consumable for the MCR II. Do not confuse this roll with the 50 × 30 m formats of the same recording family (e.g. refs. Cahnos 0992019 for Philips HeartStart or 0553048 for LIFEPAK/Nihon Kohden), which share the width but not the length or the target device.
In the Cahnos catalogue you will find variants of the same clinical recording line: the 50 × 20 m roll for the Philips Efficia CM100/DFM100 monitor/defibrillator (ref. 0553800), the white 50 × 20 m roll for multiparameter monitoring (ref. 0992456), and the 50 × 30 m rolls for other families of defibrillators and electrocardiographs (refs. 0553183 and 0553048). For other Esaote Biomedica equipment, recording blocks such as the Personal 120 (ref. 0553129) are available.
Storage: store the rolls in a cool, dry place (5–40 °C), protected from direct sunlight and excessive humidity, to preserve trace clarity and its durability in the clinical archive. The presentation in a box of 20 units ensures a constant stock in emergency departments, critical care units and medical transport.




Reviews