Thermal ECG paper roll for Cardioline E 1 / ETA 150 electrocardiographs, in 50 mm × 30 m format with pre-printed red grid. Direct thermal head printing, no ink or toner, with sharp, stable trace suitable for clinical archiving. Reproduces the construction of factory reference 03.050.05 (LESSA catalogue, OEM 8743521) and is supplied in box of 20 units under reference Cahnos 0553055-CL (line code 10302). Compatible with models E 1, ETA 150 and ETA-1 and with single-channel recorders of the Cardioline family; check width, core diameter and grid colour before replacing. Delivery in 24–72 h; B2B conditions and quotation for tenders.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0553055-CL

Description

1. Commercial Introduction

The thermal paper roll for Cardioline E 1 / ETA 150 (reference Cahnos 0553055-CL) is the recording consumable that keeps your single-channel electrocardiograph operational in cardiology practices, diagnostic centres, emergency departments and occupational medicine. Its 50 mm × 30 m format with red grid guarantees clear, stable and perfectly measurable tracings in every examination, both in resting ECG and stress tests.

The presentation in a box of 20 units allows planned and cost-effective replenishment, avoiding service interruptions due to lack of consumables. Available with delivery in 24–72 h; request a formal quotation for institutional orders, maintenance contracts and tenders.

2. Technical Explanation

This roll uses direct thermal printing technology: the electrocardiograph’s thermal head transfers heat to the paper’s heat-sensitive layer and generates the tracing instantly, without the need for ink, toner or ribbon. This reduces equipment maintenance, speeds up the output of the clinical document and maintains consistent quality throughout the entire roll. The high-sensitivity thermal paper is sized to the grammage required by the head, ensuring a tracing without blank areas or saturation.

The pre-printed red grid acts as a measurement reference (recording graph paper): it allows the amplitude of the waves (mV), the duration of the intervals (time) and the recording speeds (mm/s) to be assessed, facilitating the clinical interpretation of the electrocardiogram and its subsequent filing. As a medical recording paper with a measurement function, it belongs to the Class I medical devices range in accordance with applicable European regulations.

3. Technical Specifications

Characteristic Specification
Compatible equipment models Electrocardiographs Cardioline E 1, ETA 150 and ETA-1 (single-channel recording with thermal head)
Reference Cahnos (SKU) 0553055-CL
Paper factory reference 03.050.05 (LESSA / AB Medica Group catalogue; SKU LESSA 300281)
Declared OEM code 8743521
Distribution line code 10302 (internal code; do not use as manufacturer code)
Roll dimensions 50 mm (width) × 30 m (length)
Grid colour Red
Inner diameter of the core 19 mm (format 050×30×19E; verify the dimension accepted by the equipment)
Winding External (thermosensitive side facing outwards)
Format Roll of thermal paper (heat-sensitive)
Printing system Direct thermal via heat head (without ink, toner or ribbon)
Commercial presentation Box of 20 units
Application Single-channel electrocardiographic recording, stress testing and clinical tracings
Regulatory classification Medical device Class I (with measuring function) · CE · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC
Trace durability Declared legibility of up to 12 years for archiving (according to the paper manufacturer); verify the batch labelling
Storage Cool, dry place, 5 °C – 40 °C, protected from direct sunlight and heat sources

4. Equivalences and Cross-References

There is no equivalence table validated by the equipment manufacturer (Cardioline) that authorises third-party consumables for the E 1 / ETA 150 models. The following references share the same category (ECG thermal paper roll 50 mm × 30 m) and have been verified in public catalogues of their respective manufacturers or authorised distributors, with the indicated equivalence levels. Before substituting in a tender, the width, length, core diameter, grid colour and grammage must be verified one by one.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
LESSA / AB Medica Group (Spain) Cardioline E-1 thermal paper (OEM 8743521) 03.050.05 (LESSA catalogue; SKU 300281) Exact reference equivalence (same paper manufacturer) It is the factory code for this same construction: 50×30 m and red grid, with declared legibility of 12 years. Confirmed in the manufacturer’s official catalogue.
Ribas Medicina (authorised distributor) ECG paper roll 050×30×19E for Cardioline ETA 150 and Esaote Personal C1 6005001 Comparable by category (not interchangeable 1:1) Same dimensions 50 mm × 30 m, 19 mm core, external winding and red grid; confirmed on the manufacturer’s website. Presentation in units or pack of 10 versus the box of 20 for this reference.
Leonhard Lang (LL USA range) Chart paper ECG 50 mm × 30 m, red grid (equivalent to Kenz R50X30R-C) 8549 Comparable by category (not interchangeable 1:1) Same physical format 50×30 m and red grid; manufacturer’s own code, presentation of 50 rolls per box. Verify core diameter and grammage of the batch.
GIMA (repackaged) ECG thermal paper 50 × 30 m 32988 Comparable by category (not interchangeable 1:1) Same dimensions 50×30 m but orange grid (not red); verify the colour required by your reading protocol and the head sensitivity.

There is no equivalence table validated by the manufacturer; consult the technical department before use in a tender. The code 10302 accompanying this reference is an internal distribution line code and must not be used as a manufacturer code. Within the Cahnos catalogue itself, the same physical format 50 mm × 30 m is also supplied under references 0553055-SM (Siemens Theracard PM, red grid) and 0553055-EB (Esaote Biomedica C1-P, orange grid), as well as 0992042-CL (Cardioline Delta 1, box of 10): they share packaging and dimensions, but the equipment and grid colour must be verified before any substitution, as they are not interchangeable 1:1 without that check.

5. Selection tips and variants of interest

Check the format before replacing: the parameters that define this consumable are width 50 mm, length 30 m and red grid. Also confirm the inner core diameter that your printer accepts (standard format 050×30×19E, 19 mm core) and that your device prints via thermal head system with the appropriate weight; a different width or core may cause jams or trace misalignment.

Do not confuse the roll with a Z-fold fanfold: if your recorder prints on fanfold, select the corresponding fanfold reference from the Cardioline family. Variants of the same family at Cahnos: roll for Delta 1 of 50 mm × 30 m with red grid and box of 10 units (ref. 0992042-CL), Quicktrace HS paper of 50 × 30 m in red for 16 mm core (ref. 0553048), roll for Delta 1 Plus of 60 mm × 30 m (ref. 0553090), roll for Delta 30 D / Delta 60 D of 183 mm × 30 m (ref. 0553093-CL) and fanfold for Delta 612 of 210 × 280 mm with 200 sheets (ref. 0553180).

Store the paper in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the sensitivity of the thermal layer and the stability of the trace in the clinical record. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.

Additional information

Brand

Cardioline

Equipment model

E 1 / ETA 150 (single-channel electrocardiographs); format shared with Esaote Biomedical Personal C1

Technical reference

0553055

Distribution reference

03.050.05 (Lessa catalogue 0305005)

OEM code

8743521

Measurements

50 mm × 30 m

Length

30 m per roll

Core diameter

19 mm (format 050×30×19E; verify on the equipment)

Winding

External (thermosensitive side facing outwards)

Grid colour

Red

Format

Roll of thermal paper (heat-sensitive)

Print technology

Direct thermal via heat head (no ink or toner)

Composition

High-sensitivity thermal paper for medical recording

Presentation

Box of 20 units

Application

Single-channel electrocardiographic recording, stress testing and clinical tracings

Regulatory classification

Class I medical device (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC

Trace durability

Up to 12 years under proper storage conditions (according to the paper manufacturer)

Storage

Cool, dry place, 5 °C – 40 °C, away from direct sunlight and heat sources

Compatibility

Cardioline E 1 / ETA 150 / ETA-1 (single-channel electrocardiographs)

Manufacturer reference

03.050.05 (LESSA catalogue; SKU 300281)

Material

High-sensitivity thermal paper for medical recording

Classification

Medical device Class I (with measuring function) · CE · R.D. 1591/2009