Description
1. Product Presentation
The ECG thermal paper pad for the Siemens Burdick Atria 3000, 3100 and 6100 family is the recording consumable that guarantees clear, stable and legible electrocardiographic traces on high-end equipment. Its Z-fold format of 210×300 mm with 200 sheets per block and orange millimetre grid is designed to cover continuous data capture in resting electrocardiography, stress testing and diagnostic monitoring, with the reliability required by cardiology departments.
Marketed under the reference Cahnos 0992032 (Refs. 29.210.19 – 11560), it is equivalent to the original brand paper with factory P/Ns 007985 – 007986 / 716-0238-00, so it can be used as a direct replacement for the original consumable in the indicated equipment.
2. Technical explanation of the equipment and procedure
The Atria series electrocardiograph (as well as the Quest range) prints the recording using a thermal print head that reacts with the heat-sensitive layer of the paper, without ink or ribbons. Therefore, the quality of the trace depends directly on the thermal sensitivity, the grammage and the correct orientation of the Z-fold block: each sheet comes out continuously and folded, which facilitates loading the equipment and archiving the recording.
The orange millimetre grid allows the clinician to accurately measure intervals (PR, QT, RR), amplitudes and recording speeds on paper, while the print head prints the patient’s signal and identification data on each trace. The use of verified quality paper, with the appropriate grammage and sensitivity, prevents jams, ghost prints or premature fading of the thermal ink.
3. Technical Specifications
| Compatible models | Siemens Burdick Atria 3000 / 3100 / 6100 (and Quest range) |
| Manufacturer reference (OEM) | 007985 – 007986 / 716-0238-00 |
| Commercial SKU Cahnos | 0992032 (Refs. 29.210.19 – 11560) |
| Pad dimensions | 210 mm × 300 mm |
| Sheets per pad | 200 sheets |
| Format | Z-fold thermal paper |
| Grid colour | Orange |
| Presentation | Box of 5 units (blocks) |
| Extended compatibility (per GUDID) | Burdick 8300 / 8500, Eclipse Plus / Premier and Quest |
| Application | Medical recording: electrocardiograms, stress testing |
| Classification | Class I medical device (recording paper) |
4. Equivalences and Cross-References
The OEM reference 716-0238-00 is verified in the GUDID/FDA regulatory database (primary identifier 20817655021144), attributed to Welch Allyn, Inc. —Assurance paper, Z-fold pad, orange grid, with perforated blank header, format 210×300 mm and 200 sheets— for use with the 8300/8500, Atria, Eclipse Plus/Premier and Quest equipment. This official confirmation validates the technical construction of the code supplied in this data sheet.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| GIMA (compatible paper, distributed by Securlab, DoctorShop and DH Medical) | ECG thermal paper 210×300 mm × 200 sheets, orange grid, for Burdick Atria 3100/6100 and Quest | G-32954 / 32954 / 400132954 | Comparable by category (not interchangeable 1:1) | Same dimensions (210×300 mm), same number of sheets (200) and same orange grid; compatible with the same Atria and Quest equipment. It is not the OEM original Welch Allyn (716-0238-00) and is distributed in individual package, not in a box of 5 blocks. Verify sensitivity and grammage against the equipment IFU before replacing in a tender. |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using in a tender.
5. Selection tips and variants of interest
Select this pad when your department uses Siemens Burdick Atria 3000, 3100 or 6100 electrocardiographs: the three series share the same paper format of 210×300 mm and the orange grid, so a single reference covers the entire equipment fleet. Before replacing with a compatible paper from another brand, check the recommended grammage and thermal sensitivity in the equipment’s technical data sheet or IFU, as well as the presence of the paper-end sensor if your printer uses it.
If you have Burdick equipment from the E350/E560 range or models with a 215×280 mm format, do not use this pad: consult the specific references for your family (in the Cahnos catalogue, the 215×280 mm pads correspond to other references in the same Recording Papers category). To unify purchases between several ECG brands, contact our technical-commercial department, which will advise you on the appropriate reference for each model and offer you special B2B conditions by volume.





Reviews