Description
1. Commercial Introduction
The ECG thermal paper pad for Siemens Burdick Eclipse 4 / 400 is the recording consumable that keeps the electrocardiographs of the Eclipse 4 series and its Eclipse 400 platform operational. Its Z-fold format of 106×140 mm, with 200 sheets per pad and red millimetre grid, is designed for continuous capture of electrocardiographic traces in cardiology practices, emergency departments, occupational medicine and diagnostic units.
It is marketed under the reference Cahnos 0553053-SM (refs. 29.106.01 – 11303) and reproduces the construction of the factory P/Ns 007970 – 007971, so it can be used as a direct replacement for the original consumable in the indicated equipment. It is supplied in a box of 20 pads, with stock available and delivery in 24-72 h.
2. Technical explanation of the equipment and procedure
Siemens Burdick electrocardiographs of the Eclipse 4 / 400 series record the electrical activity of the heart by direct thermal printing: the image is generated by contact of the hot printhead on the thermosensitive layer of the paper, without the need for ink, toner or ribbon. The quality of the trace therefore depends on the thermal sensitivity of the paper, its grammage and the correct loading of the pad: the Z-fold format feeds the sheets continuously through the recorder’s drive mechanism, prevents jams and facilitates subsequent filing of the record.
The pre-printed red grid acts as a millimetre measuring reference: it allows the clinician to assess amplitudes (mV), intervals (PR, QT, RR) and recording speeds (mm/s) directly on the paper, while the printhead prints the patient’s signal and identification data on each sheet (blank header free of printing). The use of verified quality paper prevents ghost prints and premature fading of the trace in the clinical record.
3. Technical Specifications
| Characteristic | Technical detail |
|---|---|
| Model | Eclipse 4 / 400 (Siemens Burdick) |
| Manufacturer reference (P/N) | 007970 – 007971 |
| Factory reference (master catalogue) | 29.106.01 |
| Line / distribution reference | 11303 |
| SKU / commercial reference Cahnos | 0553053-SM |
| Pad dimensions | 106 mm × 140 mm |
| Capacity | 200 sheets per pad |
| Grid colour | Red |
| Format | Z-fold pad (continuous folded format) with blank header |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 blocks |
| Compatible equipment | Siemens Burdick Eclipse 4 and Eclipse 400 |
| Application | Medical recording: electrocardiograms (ECG) and stress tests |
| Classification | Class I medical device (recording paper with measuring function) |
| Trace shelf life | Approx. 5 years after printing, under normal archival conditions |
| Storage | Cool, dry place, 5 °C – 40 °C, protected from direct sunlight and heat sources |
Verification note: the P/Ns 007970 – 007971 are consistently confirmed in specialised distribution sources as the standard paper for Eclipse 4 / 400 equipment with red grid, blank header, Z-fold format and 200 sheets. In the USA, the original P/N 007971 is distributed in imperial format of 4 × 5.5 inches (≈102×140 mm), while this reference is supplied in the European metric dimension of 106×140 mm: check the sheet width that your equipment accepts before replacing a consumable from another source.
4. Equivalences and Cross-References
The factory reference 29.106.01 corresponds to the paper numbering in the master catalogue (LESSA / AB Medica Group) and the code 11303 to the distribution line reference for this same 106×140×200-sheet format with red grid. There is no official equivalence table published by the equipment manufacturer for this consumable, so the following references should be understood as functional comparisons verified in specialised distribution sources, not as an official manufacturer table. Before replacing in a tender, the sheet width (106 mm versus the 102 mm of the imperial variant), the number of sheets (200), the grid colour (red) and the grammage must be verified one by one against the equipment’s IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| EasyTrace (Modul Diagram / Modulusa, USA) | Burdick Eclipse compatible ECG paper, Z-fold, red grid, OEM 007970 / 007971 | BU106140P (ASIN B009ZZHMHU) | Comparable by category (not interchangeable 1:1) | Same metric dimensions 106×140×200 sheets and same red grid for Eclipse 4 / 400; different paper manufacturer (EasyTrace brand) and presentation in a box of 20 pads, same as this reference. Verify grammage and thermal sensitivity against the equipment’s IFU before replacing. |
| Burdick (original OEM, distributed by Discount Cardiology, USA) | Original Heartline brand for Eclipse 4 / 400, Z-fold, red grid, perforated blank header | 7971 (P/N 007971) | Comparable by category (not interchangeable 1:1) | The factory original is distributed in the USA in imperial format 4 × 5.5 inches (≈102×140 mm) versus the European metric dimension of 106×140 mm of this reference; same red grid, blank header and 200 sheets. Verify the sheet width accepted by the equipment before replacing. |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. Suppliers of the same P/N are also identified in US distribution (McKesson / Zoll Medical listing under code 007970 with 200 sheets per pack and Assurance 007970 paper in a box of 10 packs) with no additional verifiable public SKU; confirm dimensions and grid colour with the supplier.
5. Selection tips and variants of interest
Check the exact model of your equipment before ordering: this block is the one indicated for the Siemens Burdick Eclipse 4 and Eclipse 400 electrocardiographs. Always confirm the width (106 mm) and sheet height (140 mm), the number of sheets (200), the grid colour (red) and the Z-fold format: an unsuitable grid or paper weight can affect the legibility of the trace and the wear of the thermal printhead.
Do not confuse this block with other variants of the Burdick family in the Cahnos catalogue: the 210×280 mm block for Quest / Eclipse Plus / Atria (ref. 0553118), the Eclipse 8 / 800 block of 210×150 mm (ref. 0588185), the 210×300 mm block for E350/E560 (ref. 0553081-SB) or the EK 10 roll of 50 mm × 30 m (ref. 0553042). All of them belong to the same equipment family but are not interchangeable 1:1 with this reference.
Store the paper in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the sensitivity of the thermal layer and the stability of the trace in the clinical record. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formal quotation.





Reviews