Description
1. Introduction
The thermal paper roll Bionet CARDIOCARE 2000 is the reference recording consumable for 12-channel electrocardiographs that use thermal printhead printing, such as the Bionet CARDIOCARE 2000 and equipment of the same class. Its 210/215 mm × 20 m format with red grid ensures crisp, stable and perfectly measurable traces in every consultation, both in resting ECG and stress tests. Its presentation in a box of 20 units allows cost-effective and uninterrupted replenishment for cardiology clinics, emergency departments, occupational medicine and diagnostic units.
2. Technical Explanation
These electrocardiographs record the electrical activity of the heart using a direct thermal printing system: the image is generated by contact of the hot printhead on the heat-sensitive layer of the paper, without the need for ink, toner or ribbon. For the trace to be faithful and measurable, the consumable must offer thermal sensitivity appropriate to the paper weight and a pre-printed reference grid that allows the clinician to assess amplitudes (mV), intervals and recording speeds (mm/s).
This roll incorporates a red grid, the most common in clinical settings due to its excellent contrast against the white background, and its 215 mm width corresponds to the 12-channel printing format. The same format is commonly used in the market in equipment such as Bionet Cardio 7, CardioTouch 3000/5000, Carewell ECG-1112 and Trismed CARDIPIA 812 (common market use data, not manufacturer specification).
3. Technical Specifications
| Specification | Technical data |
|---|---|
| Equipment model | Bionet CARDIOCARE 2000 (12-channel ECG) |
| Reference Cahnos (SKU) | 0553171-BN |
| Factory reference | 10.215.03 |
| Distribution code | 13211 |
| Roll dimensions | 210/215 mm (width) × 20 m (length) |
| Grid colour | Red |
| Paper type | High-sensitivity thermal paper for thermal printhead |
| Print technology | Direct thermal (without ink, toner or ribbon) |
| Application | Recording of electrocardiograms (ECG), stress tests and other medical recordings on equipment with compatible thermal printhead |
| Commercial presentation | Box of 20 units |
| Regulatory classification | Class I (with measuring function) · RD 1591/2009 · Directives 93/42/EEC and 2007/47/EC (according to the technical data sheet of the authorised supplier of the consumable) |
| Trace shelf life | 5 years after printing (refer to the product instructions) |
| Storage | Between 5 °C and 40 °C; avoid direct sunlight, excessive humidity and heat sources |
4. Equivalences and Cross-References
There is no equivalence table validated by the equipment manufacturer that authorises third-party consumables; the following references are offered as functional comparisons verified in catalogues of authorised distributors and must be confirmed with the technical department before use in tendering. All of them share the same category (12-channel ECG thermal paper roll, 215 mm width) with red or orange grid.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Trismed | CARDIPIA 800 / 812N / 812P / 812R / 812RS | 0553171-TM | Comparable by category (not interchangeable 1:1) | Same dimensions 215 × 20 m and same base reference 0553171, but orange grid (in this data sheet, red); box of 20 units. |
| Lessa / AB Medica Group (Spain) | Bionet ECG CARDIOCARE 2000 / 2002 | Cat. 1021503 (SKU 300166) | Comparable by category (not interchangeable 1:1) | 215 × 25 m (length greater than 20 m), red grid; Quicktrace® HS quality and 12-year archival legibility. Confirmed in the authorised supplier’s data sheet. |
| Quality Chart Paper (USA) | Bionet Cardiocare 2000 / Cardiotouch 3000 | BNT21525 | Comparable by category (not interchangeable 1:1) | 215 × 25 m, red grid, presentation of 5 rolls per box. Confirmed in the manufacturer’s catalogue. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. Traceability note: the master catalogue of recording papers associates the same base reference (0553171) with the Bionet CARDIOCARE 2000/2002, CARDIO 7 and CARDIOTOUCH 3000/5000 equipment, and also with the roll for Carewell ECG-1112, which confirms its shared use among equipment of the same 12-channel class. Likewise, the Australian distributor Getz Healthcare catalogues this same format (215 × 20 m, red grid) as compatible with BIONET/PROGETTI ECG CARDIOCARE 2000. Always verify the length declared by your supplier (20 m in this data sheet; some market versions are distributed at 25 m) and the core diameter before replacing.
5. Selection tips and variants of interest
Check the exact model of your electrocardiograph: this roll is designed for 12-channel equipment with a 210/215 mm wide printer (type Bionet CARDIOCARE 2000). Always verify the width, core diameter and grid colour before replacing the consumable; an inappropriate paper weight or grid can affect the legibility of the recording and the wear of the thermal printhead.
Grid colour: this data sheet corresponds to a red grid. Versions of the same format with an orange grid (for example, reference 0553171-TM for Trismed CARDIPIA 800/812) are not interchangeable without prior verification on the equipment.
Variants of the same family in Cahnos: roll of Progetti CARDIOCARE 2000 in the same format 215 × 20 m (ref. 0553171-PG); roll of CARDIO TOUCH, 210 mm × 25 m (ref. 0553135); roll of Cardioline DELTA 60 PLUS, 210 mm × 30 m (ref. 0553172); and roll of Progetti EPG Pocket / View, 58 mm × 25 m (ref. 0992004) for single-channel electrocardiographs.
Storage: store the roll in a cool, dry place (stable temperature between 5 °C and 40 °C), protected from direct sunlight and heat sources, to preserve tracing quality and image stability in the clinical archive. For institutional orders or tenders, contact our technical-commercial department to confirm compatibility and supply conditions per full box.