Description
1. Introduction
The MULTIPAD system from Pearltec (Pearl Technology AG, Switzerland) is the European reference solution for patient placement, positioning and fixation during magnetic resonance imaging and computed tomography examinations. Designed for diagnostic radiology services, operating theatres and intensive care units, this system of anatomical pads ensures comfortable, stable and reproducible immobilisation in every examination, resulting in sharper images, fewer sequence repetitions and real time savings per examination. Available on request under its master reference CAHPEARL001, with its Standard, Plus, Slim, Ear and Bendy variants.
2. Technical explanation
The MULTIPAD pads act as an immobilisation system by volume adaptation: the professional places the pad between the patient and the coil or the examination table, gently moulds the core of high-fluidity expanded polystyrene (EPS) beads until achieving a perfect anatomical support and extracts the air through the fixation valve, so that the piece stiffens while maintaining the desired shape without generating localised pressure points. The sealed cover of thermoplastic polyurethane (TPU) film is durable, washable and acts as a hygienic barrier between patients.
As it is completely free of metallic or ferromagnetic components, the system is totally safe in the MRI environment, reduces micromovements and motion artefacts, improves the signal-to-noise ratio and preserves the integrity of the diagnostic image. Its reusable and easy-to-clean design makes it a cost-effective and sustainable investment for any medical imaging service.
3. Technical Specifications
General features of the MULTIPAD system
| Manufacturer | Pearltec (Pearl Technology AG, Switzerland) |
| Master reference / SKU | CAHPEARL001 |
| Product type | Adaptable pad-type patient positioning and immobilisation system |
| Cover material | Thermoplastic polyurethane (TPU) film, durable and washable |
| Core | Expanded polystyrene (EPS) beads with high adaptability |
| Fixation system | Anatomical moulding with air extraction valve |
| Compatibility | Magnetic resonance imaging (MRI), computed tomography (CT) and radiology; free of metallic components (MRI-safe) |
| Intended use | Head, cervical spine, shoulder, extremities, knee and irregular anatomical areas |
| Type of use | Reusable and washable |
| Cleaning | Neutral soap and water or standard disinfectant solution; do not immerse or puncture |
| Presentation | Pads per unit; disposable hygienic covers Cover MULTIPAD available on request |
Range of MULTIPAD positioners available at Cahnos
| Model | Reference | Dimensions | Thickness |
| MULTIPAD Standard | 1022-PS | 17 x 6 cm | 2 – 5 cm |
| MULTIPAD Plus | 1071-PS | 17 x 11 cm | 2 – 5 cm |
| MULTIPAD Slim | 1104-PS | 17 x 9 cm | 1 – 3 cm |
| MULTIPAD Ear | 1107-PS | 17 x 10 cm | 1 – 4 cm |
| MULTIPAD Bendy | 1112-PS | 23 x 9 cm | 1 – 4 cm |
4. Equivalences and Cross-References
The MULTIPAD system belongs to the positioning family of the Swiss manufacturer Pearl Technology AG (Pearltec). In the European market, the pads in this range are marketed under equivalent references from other distributors: MRI-4138 (allMRI) and 124822 (Merry X-Ray) for the Standard model; MRI-4140 (allMRI) and 1022 (Rothband) for the Plus model; MRI-4159 (allMRI) and PA-608 (MRIMed) for the Ear model. All of them are functionally interchangeable in terms of fitting into standard coils and performance.
The clinical concept of immobilisation by volume adaptation is comparable to that of gel cushions and positioners from other manufacturers in the sector such as RCN (ELACTON gel), AliMed or Trulife/Oasis, as well as to the vacuum positioning systems used in diagnostic radiology and radiotherapy, which pursue the same objective of stable fixation, comfort and prevention of pressure injuries. In the Cahnos catalogue, the Pearltec foam pads (CAH-PEARLTEC and CAH-PEARLTEC-2) for Nuclear Medicine and Radiology complement the service’s positioning equipment.
5. Selection tips and variants of interest
Select each MULTIPAD pad according to the size of the gap to be filled and the anatomical area to be immobilised: the MULTIPAD Standard (1022-PS) is the versatile all-purpose option; the MULTIPAD Plus (1071-PS) covers large spaces (knee, shoulder or high-volume areas); the MULTIPAD Slim (1104-PS) is indicated for very confined spaces and sensitive areas; the MULTIPAD Ear (1107-PS) protects and stabilises the auricular area; and the MULTIPAD Bendy (1112-PS) offers maximum flexibility for joints and irregular surfaces.
For optimal hygienic use, complement the positioners with the disposable Cover MULTIPAD covers from the same manufacturer (available on request) and clean the surface after each use with water and neutral soap or standard disinfectant, avoiding sharp objects that could damage the cover and without submerging or forcing the valve. Before placing the order, confirm the dimensions of the coil or examination table. For institutional purchases, tenders or special supply conditions, consult your technical-commercial advisor at Cahnos.