Description
1. Commercial Introduction
Safety in a Magnetic Resonance Imaging (MRI) service leaves no room for improvisation: the greatest risk lies in metallic objects which, from a patient’s pocket or a companion’s trolley, can become projectiles within the magnetic field of the magnet. The MR-safe metal detector R-MN-01 is the verification tool your facility needs to carry out fast, reliable and interference-free checks, with the decisive advantage that it can be used inside the scanning room itself (zone 4) without any risk of being attracted or damaged by the magnet.
Its fully anti-magnetic design, its power supply from high-capacity rechargeable batteries and its ergonomic handling make it an essential accessory for radiologists, senior diagnostic imaging technicians (TSID), nursing staff and hospital safety officers.
2. Technical explanation of the device
This detector operates as a portable manual scanning device that identifies the disturbance generated by a metallic object in its detection area, allowing the operator to locate the item precisely during inspection of the patient, companion or staff.
Its main technical differentiator is the separate detection of ferrous (magnetic) and non-ferrous (non-magnetic) metallic objects. This dual capability is key in the MRI environment: it allows identification of both elements that pose a projectile effect risk due to their ferromagnetic nature (the critical hazard in zone 4) and non-ferrous metals associated with radiofrequency heating risk. As it is a fully anti-magnetic (MR-safe) device, it can be used inside the scanning room without compromising performance or creating a potential projection risk, right at the point of greatest risk, before access to the magnet.
3. Technical Specifications
| Characteristic | Specification |
| Reference (SKU) | R-MN-01 |
| Device type | Portable MR-safe ferromagnetic metal detector |
| Detection type | Separate detection of ferrous and non-ferrous metal objects |
| MR-safe safety | Completely non-magnetic construction; suitable for use inside the MRI room (zone 4) |
| Projectile risk | None: not attracted by the magnet’s magnetic field |
| Power supply | High-capacity rechargeable batteries for extended operation |
| Design | Ergonomic and lightweight, designed for prolonged use |
| Application | Safety screening of patients, companions and staff in MRI rooms |
| Presentation | Unit |
The detection, zone safety and construction data correspond to the technical data sheet and internal product documentation; for the numerical sensitivity specification and accessories, consult the equipment manual.
4. Equivalences and Cross-References
The reference R-MN-01 falls within the category of portable dual-detection ferromagnetic detectors for patient screening before MRI, a well-established family on the international market. The following cross-references have been checked against the official catalogues and technical data sheets of the respective manufacturers and must be verified field by field before any substitution in a tender:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| CEIA (Italy) | PD240CH-Z4 — Portable dual-detection ferromagnetic detector | PD240CH-Z4 | Comparable by category (not interchangeable 1:1) | Separate detection of ferrous and non-ferrous objects, non-ferromagnetic construction suitable for use in zone 4, three operating modes and dual-tone audible signal with two-colour indicator. Verified on the official CEIA website. |
| Magmedix | Hand-Held Patient Screener | 03-PD240CH | Comparable by category (not interchangeable 1:1) | North American market version of the dual-detection detector for patient screening (ferrous and non-ferrous). Verified on the distributor’s official website; confirm the power supply and accessories of the local version before substituting. |
| MRImed | Hand-Held Ferromagnetic Detector | SM-305 | Comparable by category (not interchangeable 1:1) | Independent detection of ferrous and non-ferrous metals with rechargeable batteries and three analysis modes. Key difference: classified as MR Unsafe, not suitable for use in zone 4 (intended for zones II and III), unlike the R-MN-01 which is safe inside the room. |
There is no equivalence table validated by the manufacturer for the reference R-MN-01; consult the technical department of Cahnos before using it in a tender. Other homologous families of scanning detectors for MRI safety screening present in the sector include, among others, the Ferroguard Screener system from Metrasens and the range of dual-detection detectors distributed under the Magmedix brand; in all cases, zone compatibility, detection type, power supply and accessories must be verified before any substitution.
5. Selection tips and variants of interest
- Control point: take advantage of the equipment’s MR-safe condition to carry out verification inside the room itself (zone 4), just before access to the magnet, where the projectile risk is greatest; for previous access points you can combine it with an access scanning detector (ref. CAHIRM6689).
- Selective verification: by distinguishing ferrous and non-ferrous separately, prioritise the location of ferromagnetic elements (projectile nature) and use the non-ferrous alert for objects associated with radiofrequency heating.
- Protocol reinforcement: complement with a test magnet (ref. CAHIRM8002) for spot-checking specific objects or devices and with the Sensitive digital detector (ref. CAHIRM8022) if your service prefers fully digital technology with a docking station.
- Maintenance: establish a battery recharging routine at the end of each shift and define a standardised scanning procedure to ensure complete coverage of the person being inspected.
- Documentation: for tender specifications and competitions, request from the technical-commercial department of Cahnos the technical data sheet and conformity documentation that allow validation of the reference R-MN-01.
Our technical-commercial team at Cahnos can advise you on the comprehensive safety provision for your Magnetic Resonance Imaging service and on the standardisation of references with other manufacturers.