We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Colourless Non-Absorbable Polypropylene Surgical Mesh Premisut Mesh Regular 7.5 x 15 cm – Monofilament 80 g/m² for Hernias and Abdominal Wall (Ref. PPMR7,515)

13,96 €

Surgical mesh of colourless non-absorbable polypropylene, model Premisut Mesh Regular, in 7.5 x 15 cm format (Ref. PPMR7,515). Extruded monofilament synthetic fabric without coating, with laser cutting that seals the edges and prevents fraying, offering excellent multidirectional mechanical properties. Weight 80 g/m², pore 0.5 x 0.7 mm, thickness 0.50 mm and maximum force 25 kgf with permanent tensile strength. Indicated for abdominal wall reinforcement and repair of inguinal, femoral, umbilical and ventral hernias, suitable for open and laparoscopic surgery. Sterilised by ethylene oxide; single-use in individual sterile pouch. Minimum purchase unit: 25 units (price per unit).

International shipping. Import duties and taxes are payable by the recipient.

Reference
PPMR7.515

Description

1. Introduction

The Premisut Mesh Regular surgical mesh, 7.5 x 15 cm (Ref. PPMR7,515), is a tissue reinforcement implant made from colourless, non-absorbable polypropylene, designed for surgeons and purchasing departments that need a standard-density mesh (80 g/m²) that is reliable and offers excellent value for money for abdominal wall repair and hernia treatment. Its woven monofilament structure, laser cutting and multidirectional mechanical properties make it a robust solution for both open and laparoscopic techniques, with the assurance of a sterile, single-use product and the specialised technical support of Cahnos.

2. Technical Explanation

The mesh is made from 100% extruded monofilament polypropylene, a biostable polymer that is neither absorbed nor degraded by enzymatic action of tissue: the reinforcement remains permanently in the body, offering permanent tensile strength. The fabric interlaces the fibres in multiple directions, providing bidirectional elasticity and a balanced distribution of loads on the abdominal wall, allowing the mesh to be cut and adapted to the shape and size of the defect without fraying.

Laser cutting seals the edges and prevents fraying, ensuring a precise shape. Its pore size of 0.5 x 0.7 mm promotes controlled tissue integration, allowing fibrous tissue growth through the interstices. It is mainly indicated for abdominal wall reinforcement and the treatment of inguinal, femoral, umbilical and ventral hernias, in both open and laparoscopic surgery. It is supplied sterile by ethylene oxide; do not re-sterilise and always consult the instructions for use (IFU) before implantation.

3. Technical Specifications

The Premisut Mesh Regular 7.5 x 15 cm mesh has the following technical specifications, copied literally from the product documentation:

Parameter Specification
Reference / SKU PPMR7,515
Dimensions 7.5 x 15 cm
Material Extruded monofilament polypropylene, colourless and non-absorbable
Structure Uncoated fabric, natural white colour, laser cut
Pore size 0.5 x 0.7 mm
Weight 80 g/m²
Elongation 89 %
Thickness 0.50 mm
Maximum force 25 kgf
Tensile strength Permanent; not absorbed due to its technical characteristics
Sterilisation Ethylene oxide (EO). Do not resterilise
Use Single-use, individual sterile pouch
Presentation Sterile unit; minimum purchase unit: 25 units
Indications Abdominal wall reinforcement; inguinal, femoral, umbilical and ventral hernias
Techniques Open and laparoscopic surgery

4. Equivalences and Cross-References

There is no official cross-reference table validated by the manufacturer for this mesh. The references indicated below are functional category comparisons (same product type and general clinical indication, with verifiable technical differences) and are not interchangeable 1:1: before substituting in a tender or protocol, they must be validated field by field and the official technical data sheets of each manufacturer must be consulted.

Manufacturer / Brand Family / Model Code / Reference Equivalence level Technical differences / Remarks
B. Braun Premilene® Mesh (15 x 15 cm) 1064435 Comparable by category, not interchangeable 1:1 Non-absorbable monofilament polypropylene; higher density (82 g/m²), pore 0.8 mm, thickness 0.48 mm. No 7.5 x 15 format in the standard catalogue
Johnson & Johnson MedTech (Ethicon) PROLENE® Polypropylene Mesh (8 x 15 cm) PMI / PMII Comparable by category, not interchangeable 1:1 Non-absorbable monofilament polypropylene for inguinal and ventral hernia; weight above 95 g/m²; verify weight, pore and format in official data sheet
Medtronic (Covidien) Parietene™ Macroporous Mesh (15 x 15 cm) PPM1515 Comparable by category, not interchangeable 1:1 Two-dimensional macroporous monofilament polypropylene mesh, extraperitoneal placement according to IFU; verify weight, pore and dimensions in the official technical data sheet
Cahnos Premisut Mesh Regular (same range, other sizes) PPMR611 / PPMR1015 / PPMR1215 / PPMR1515 / PPMR1520 / PPMR1530 / PPMR2030 Range equivalence with identical specifications, different size Same line: 80 g/m², pore 0.5 x 0.7 mm, thickness 0.50 mm and maximum force 25 kgf; only the dimensions change
Cahnos PremisutMesh Lite 7.5 x 15 PPML7,515 Comparable by category, not interchangeable 1:1 Same size 7.5 x 15, but light line: 45 g/m², pore 1.3 x 1.0 mm, thickness 0.43 mm and maximum force 19 kgf

Fields to check before any substitution: exact dimensions, weight (g/m²), pore size, thickness, structure (monofilament/multifilament), coating, single-use, CE/MDR classification and sterilisation method. There is no equivalence table validated by the manufacturer; consult the technical department before use in a tender.

5. Selection tips and variants of interest

The 7.5 x 15 cm format is a recommended size for inguinal, umbilical hernias and small abdominal wall defects in adults, covering the defect with an overlap of 3 to 5 cm over healthy tissue in ventral or incisional hernia. For larger defects, the same Premisut Mesh Regular line maintains identical specifications (80 g/m², pore 0.5 x 0.7 mm, thickness 0.50 mm, maximum force 25 kgf) in other formats: PPMR611 (6 x 11), PPMR1015 (10 x 15), PPMR1215 (12 x 15), PPMR1515 (15 x 15), PPMR1520 (15 x 20), PPMR1530 (15 x 30) and PPMR2030 (20 x 30).

If the centre’s protocol prefers a lighter, macroporous mesh to reduce the feeling of a foreign body, the alternative within the Cahnos catalogue is the PremisutMesh Lite line (45 g/m², pore 1.3 x 1.0 mm), also available in 7.5 x 15 cm (Ref. PPML7,515). Remember that this mesh must not be used in direct contact with viscera (intraperitoneal route) and that fixation will be performed with sutures or staples at the surgeon’s discretion, always following the manufacturer’s IFU. All meshes in this range are sold with a minimum purchase unit of 25 units, ideal for standardising stock in the surgical area and optimising the cost per procedure.

Additional information

Reference

PPMR7,515

Material

Extruded monofilament polypropylene (100% PP), colourless and non-absorbable

Structure

Single-layer woven mesh, uncoated, natural white colour, laser-cut

Measurements

7.5 x 15 cm

Pore size

0.5 x 0.7 mm

Weight

80 g/m²

Thickness

0.50 mm

Elongation

89 %

Maximum force

25 kgf

Tensile strength

Permanent; not absorbed due to its technical characteristics

Absorbability

Non-absorbable

Sterilisation

Ethylene oxide (EO). Do not resterilise

Use

Single-use, individual sterile pouch

Presentation

Sterile unit; minimum purchase unit: 25 units

Indications

Abdominal wall reinforcement; inguinal, femoral, umbilical and ventral hernias

Techniques

Open and laparoscopic surgery

Reviews

There are no reviews yet.

Be the first to review “Colourless Non-Absorbable Polypropylene Surgical Mesh Premisut Mesh Regular 7.5 x 15 cm – Monofilament 80 g/m² for Hernias and Abdominal Wall (Ref. PPMR7,515)”

Your email address will not be published. Required fields are marked *