Description
1. Introduction
The PremisutMesh Lite surgical mesh 7.5×15 cm (Ref. PPML7,515) is the tissue reinforcement solution your general surgery department needs: a lightweight, macroporous implant that is easy to handle, designed for abdominal wall repair with an excellent cost-effectiveness ratio for hospitals, private clinics and distributors. Its uncoated monofilament polypropylene construction minimises the sensation of a foreign body and promotes controlled tissue integration, making it a common choice for inguinal, umbilical and ventral hernioplasties, both in open tension-free and laparoscopic techniques. It is marketed with a minimum purchase unit of 25 units and price per unit, ideal for standardising stock in the surgical area and optimising the cost per procedure.
2. Technical Explanation
The PremisutMesh Lite is manufactured from 100% extruded monofilament polypropylene, a biostable polymer that is neither absorbed nor degraded by the enzymatic action of tissues: the reinforcement remains permanently in the body, maintaining its tensile strength throughout the life of the implant. The fabric interlaces the fibres in multiple directions, providing bidirectional elasticity and a balanced distribution of loads over the abdominal wall, allowing the mesh to be adapted and trimmed to the shape and size of the defect without fraying. Its macroporous structure of 1.3×1.0 mm allows fibrous tissue growth through the interstices, incorporating the mesh into the adjacent tissue and reducing the risk of fold formation. Laser cutting seals the edges and prevents fraying, ensuring precise shape and properties with exceptional tear resistance. It is indicated for abdominal wall reinforcement and repair of inguinal, femoral, umbilical and ventral hernias, suitable for open and laparoscopic techniques, and must be used following the manufacturer’s instructions for use (IFU). Note: it should not be used in direct contact with viscera (intraperitoneal route).
3. Technical Specifications
The PremisutMesh Lite 7.5×15 cm mesh has the following technical specifications, taken literally from the product documentation:
| Specification | Value |
|---|---|
| Reference | PPML7,515 |
| Material | Extruded monofilament polypropylene (100 % PP), colourless and non-absorbable |
| Structure | Synthetic single-layer woven mesh, uncoated, natural white colour |
| Dimensions | 7.5 × 15 cm |
| Pore size | 1.3 × 1.0 mm (macroporous) |
| Weight | 45 g/m² |
| Thickness | 0.43 mm |
| Elongation | 77 % |
| Maximum force | 19 kgf |
| Tensile strength | Permanent; not absorbed by the body |
| Cut / finish | Laser cut, sealed edges without fraying |
| Sterilisation | Ethylene oxide (EO). Do not resterilise |
| Use | Single-use, individual sterile pouch |
| Indications | Abdominal wall reinforcement; inguinal, femoral, umbilical and ventral hernias |
| Techniques | Open and laparoscopic surgery |
| Presentation | Minimum purchase unit: 25 units (price per unit) |
4. Equivalences and Cross-References
Important: there is no official cross-reference table validated by the manufacturer for PremisutMesh Lite against other brands. The references indicated below are functional category comparisons (same type of product and general clinical indication, with verifiable technical differences) and are not 1:1 interchangeable without verifying the technical data sheet of each manufacturer. Before use in tenders, consult the technical department at Cahnos.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | Premilene® Mesh (7.5 × 15 cm) | 1064425 | Comparable by category, not interchangeable 1:1 | Non-absorbable woven monofilament polypropylene for hernioplasty; standard density mesh (approx. 82 g/m²), tighter pore (approx. 0.8 mm) and 0.48 mm thickness |
| Johnson & Johnson MedTech (Ethicon) | PROLENE® Polypropylene Mesh | Consult official catalogue for 7.5 × 15 size | Comparable by category, not interchangeable 1:1 | Non-absorbable monofilament polypropylene for ventral and inguinal hernia repair; standard weight mesh without 45 g/m² specification. Verify the reference for the size |
| Medtronic (Covidien) | Parietene™ Macroporous Mesh | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Macroporous monofilament polypropylene mesh for hernia repair; verify weight, pore and sizes against the official technical data sheet |
| BD (Bard) | Bard® Soft Mesh | 0117011 (15 × 15 cm); verify 7.5 × 15 size | Comparable by category, not interchangeable 1:1 | Large-pore soft mesh, approx. 60 % lighter than traditional meshes; check weight and pore against 45 g/m² |
| Cahnos | Premisut Mesh Regular 7.5×15 | PPMR7,515 | Comparable by category, not interchangeable 1:1 | Same manufacturer and same size, but higher density mesh: 80 g/m², pore 0.5 × 0.7 mm, thickness 0.50 mm and maximum force 25 kgf |
Fields to check before any substitution: exact dimensions, weight (g/m²), pore size, thickness, structure (monofilament/multifilament), coating, single use, CE/MDR classification and sterilisation method. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The 7.5 × 15 cm format is a reference size for inguinal hernias and small or medium abdominal wall defects in adults, covering the defect with a 3 to 5 cm overlap over healthy tissue in ventral or incisional hernia. The entire PremisutMesh Lite line shares the same technical specifications (45 g/m², pore 1.3 × 1.0 mm and maximum force 19 kgf) in various sizes, allowing the size to be adjusted to the defect and avoiding waste: PPML611 (6×11), PPML1015 (10×15), PPML1215 (12×15), PPML1515 (15×15), PPML1520 (15×20), PPML1530 (15×30), PPML2030 (20×30) and PPML3030 (30×30). If the centre’s protocol requires a higher density mesh for defects with high tension or weakened tissue, the alternative within the Cahnos catalogue is the Premisut Mesh Regular line (80 g/m², pore 0.5 × 0.7 mm, 25 kgf), also available in 7.5 × 15 cm (Ref. PPMR7,515). Remember that the mesh is for single use, must not be re-sterilised or implanted in direct contact with viscera, and fixation will be performed with sutures or staples at the surgeon’s discretion, always following the manufacturer’s IFU and verifying the CE/MDR marking of the supplied batch.