Description
1. Introduction
This 1-3 MHz ultrasound head, reference 28302, is the replacement applicator designed specifically for the UTC 2 ultrasound therapy equipment (code 28301). It guarantees the original replacement of the handpiece, always preserving the performance and compatibility of the equipment. An essential solution for physiotherapy clinics, rehabilitation centres and sports medicine practices that need to replace or expand the applied part of their ultrasound device.
2. Technical explanation of the equipment
Ultrasound therapy uses high-frequency ultrasound waves that act on soft tissues generating thermal, mechanical and biological effects: deep heating, analgesic effect, relaxation of muscle contractures and improved joint mobility. This head works at frequencies from 1 to 3 MHz, allowing the wave penetration to be adapted to the depth of the area to be treated: 1 MHz for deep and bulky tissues and 3 MHz for superficial areas, tendons and small joints.
The applicator is used in direct contact with the skin, always with coupling gel to ensure correct transmission of the beam and patient comfort. As it is the specific applied part of the UTC 2, it must be used with that equipment to ensure safe and effective operation.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Working frequency | 1-3 MHz |
| Head diameter | 15 mm |
| Application type | Direct contact (with coupling gel) |
| Compatible equipment | UTC 2 (code 28301) |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | II A |
| EAN | 8033638326466 |
Available references
| SKU Cahnos | GM28302 |
|---|---|
| Manufacturer reference | 28302 |
| Compatible equipment reference | 28301 (UTC 2) |
| EAN / GTIN | 8033638326466 |
| Sales unit | 1 unit |
4. Equivalences and Cross-References
There is no officially validated equivalence table with other manufacturers for this reference; before any substitution in a tender, it must be checked property by property with the technical department of Cahnos.
Within the manufacturer’s catalogue, this head (ref. 28302) is the original applicator of the UTC 2 ultrasound therapy equipment (ref. 28301), of which it constitutes the replacement applied part. The ultrasound therapy range is completed with equipment such as the MIO-SONIC (ref. 28309), the POWERSONIC (ref. 28308) and the professional I-TECH UT2 with two catheters (ref. 28358), which share therapeutic principles and clinical applications with the UTC 2.
5. Selection tips and variants of interest
Always verify that the head corresponds to the exact reference of your equipment: this 15 mm applicator is indicated exclusively for the UTC 2 (code 28301). If you have any doubt about the compatibility of your equipment or the need for other applied parts, consult our technical-commercial department before placing the order.
Remember to replenish the ultrasound coupling gel, essential to ensure correct transmission of the beam and patient comfort during the session. As it is a class II A medical device, its use must be carried out following the instructions in the manufacturer’s manual. For large orders you can request a quote.





Reviews