Description
TENS electrode 35 × 45 mm TST with cable: professional consumable for electrostimulation
The TENS electrode of 35 × 45 mm in non-woven fabric (TST) with integrated cable and 2 mm socket-type connector (ref. PG470W) is the disposable consumable that your clinic or physiotherapy centre needs to keep its electrostimulation equipment always operational. Its compact rectangular format is designed for areas with a reduced or contoured surface: cervical, shoulder, elbow, wrist, ankle, hands and trigger points, both in TENS analgesia and in EMS muscle re-education programmes.
Each electrode is fully gelled and ready to use, with the guarantee of a new electrode in each session: maximum hygiene, constant adhesion and predictable performance in each treatment. Its presentation in bag of 40 units reduces the cost per electrode and simplifies stock management in intensive-use environments.
Technical explanation: TENS, EMS and standard 2 mm connection
Transcutaneous electrical nerve stimulation (TENS) uses low-frequency electrical impulses for pain relief, while electrical muscle stimulation (EMS) seeks muscle contraction and re-education. In both cases, the electrode acts as a conductive interface between the device and the patient’s skin, so its quality determines the uniformity of the impulse and the comfort of the session.
TST means non-woven fabric (non-woven): a flexible, breathable textile support that is highly adaptable to the anatomical contour. This electrode incorporates biocompatible medical conductive adhesive solid gel and low-impedance conductive paper, ensuring a homogeneous distribution of the current that minimises high-density points (hot spots) and discomfort during stimulation.
The 2 mm socket-type connector (female) with integrated cable is the most widespread standard in physiotherapy TENS/EMS stimulators, which guarantees compatibility with most equipment from leading manufacturers without the need for adapters. It is a single-patient product, latex-free and classified as a class I medical device according to Directive 93/42/EEC, with a shelf life of 24 months from its production date.
Technical specifications
| Parameter | Specification |
|---|---|
| Reference / SKU | PG470W |
| Electrode type | Disposable, fully gelled for TENS/EMS |
| Dimensions | 35 × 45 mm (rectangular) |
| Support / material | Non-woven fabric (TST / non-woven) |
| Gel | Biocompatible medical conductive adhesive solid gel |
| Conductive material | Low-impedance conductive paper |
| Connection | 2 mm socket-type connector (female) with integrated cable |
| Compatibility | TENS/EMS equipment with standard 2 mm connector |
| Use | Disposable, single patient |
| Latex | Latex-free |
| Presentation | Bag of 40 units |
| Regulatory compliance | Class I medical device (Directive 93/42/EEC and amendments) |
| Expiry | 24 months from the date of production |
| Storage | Temperature +5 °C to +35 °C; relative humidity 20–80 % |
Family of TST electrodes with cable and 2 mm connector – available variants
| Reference | Format | Connection | Presentation |
|---|---|---|---|
| PG470W | Rectangular 35 × 45 mm | 2 mm socket type | Bag 40 units |
| PG471/50W | Square 50 × 50 mm | 2 mm socket type | Bag 40 units |
| PG472/90W | Rectangular 50 × 90 mm | 2 mm socket type | Bag 40 units |
| PG476W | Rectangular 45 × 150 mm | 2 mm socket type | Bag 40 units |
| PG479/32W | Round Ø 32 mm | 2 mm socket type | Bag 40 units |
| PG479/50W | Round Ø 50 mm | 2 mm socket type | Bag 40 units |
| PG479/75W | Round Ø 75 mm | 2 mm socket type | Bag 40 units |
Equivalences and cross-references
The reference PG470W corresponds to the official factory code of the product: disposable fully gelled electrode, non-woven fabric (TST) support, rectangular format of 35 × 45 mm, with integrated cable and 2 mm socket-type connector, verified in the technical catalogue of the family. No official cross-reference table published by the manufacturer has been found; the alternatives from other brands indicated below are category comparisons checked against each supplier’s catalogue, not 1:1 equivalents. Always verify the manufacturer’s technical data sheet before replacing.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| MedTrade (Spain) | Electrostimulation and EMG electrode with cable | 13020 | Comparable by category (not interchangeable 1:1) | Same size 35 × 45 mm and connection with standard 2 mm cable; solid conductive gel; presentation in blister of 8 units versus bag of 40 units; confirm the support material (TST/foam) in the brand’s technical data sheet before replacing. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As a market compatibility reference (not manufacturer specification), the standard 2 mm socket-type connector with integrated cable of this electrode is the one habitually used by TENS/EMS physiotherapy equipment from brands such as Compex (DJO/Enovis), Globus, Pals (Axelgaard), Schwa-medico, ITO Physiomed, Cefar and Tensmed, as well as by any electrostimulator compatible with a 2 mm socket; the specific replacement references for each brand must be verified one by one (measurements, backing material, gel type and disposable/reusable condition) before any possible substitution. Remember that an electrode with a press-stud connection (snap, button type) is not interchangeable with this cable version without the appropriate cable or adapter.
Selection tips and variants of interest
The rectangular 35 × 45 mm format is the right choice for small or contoured areas: cervical musculature, shoulder, elbow, wrist, ankle, hands, trigger points and small joints. First confirm the connection type of your device: if your electrostimulator uses a cable output with a 2 mm socket-type connector (like this model), this reference is the direct option; if it uses a press-stud connection (snap, Compex type), choose the same size version with button (ref. PG470) and not this cable version.
For medium-sized areas (knee, thigh, calf) there is the 50 × 50 mm square (ref. PG471/50W) or the 50 × 90 mm rectangular (ref. PG472/90W); for large muscle groups and extensive surfaces, the 45 × 150 mm formats (ref. PG476W) or round Ø 50 and Ø 75 mm (ref. PG479/50W and PG479/75W); for highly localised points, the round Ø 32 mm (ref. PG479/32W). If you prefer another backing material, the foam range with cable and 2 mm socket is available in 40 × 40 mm (ref. PG871/40W) and 50 × 50 mm (ref. PG871/50W).
To maintain optimal conductivity and secure fixation: prepare clean, dry, cream-free skin before application, keep the packaging closed in a cool, dry place (5 °C to 35 °C, relative humidity 20–80%), observe the 24-month expiry date and replace the electrode for each patient to ensure hygiene, adhesion and consistent performance. The 40-unit bag allows cost-effective replacement scheduling and always keeps electrodes in optimal condition in clinics, rehabilitation centres and pain treatment practices.