Description
1. Introduction
The Medline nasal oxygen catheter is the ideal solution for administering supplemental or increased-flow oxygen to patients requiring respiratory support, particularly in the ICU and when a face mask is too intrusive for the patient. It is part of the Medline oxygen therapy portfolio, which includes nasal cannulas and accessories for adult and paediatric patients, and is available in several diameters to suit the individual needs of each therapy.
2. Technical Explanation
The distal end of the nasal catheter is open and features a straight conical PVC connector that must be connected to an oxygen source with a recommended low-flow rate (≤ 6 l/min). The proximal end incorporates a polyether foam piece that ensures comfortable and stable placement inside the patient’s nostril, minimising discomfort during prolonged therapies. The catheter is 40 cm long and made of PVC, which gives it flexibility and strength. Its sterile, single-use nature helps prevent cross-contamination between patients.
3. Technical specifications and tables
Specifications declared by the manufacturer Medline for the nasal oxygen catheter family (Medline family P-DL67S, category Respiratory > Oxygen therapy > Cannulas and Tubes):
| Characteristic | Value |
|---|---|
| Brand | Medline |
| Original manufacturer | Medline International (medline.eu) |
| SKU Cahnos | MDLP-DL67S |
| Medline family | P-DL67S |
| Product type | Low-flow nasal oxygen therapy catheter |
| Length | 40 cm |
| Material | PVC |
| Sterilisation | Yes |
| Recommended flow rate | ≤ 6 l/min |
| Use | Single-use (disposable) |
Available references
| Reference | Diameter | Units per box | Units per pack | Units per bag |
|---|---|---|---|---|
| 820608 | CH08 | 600 | 100 | |
| 820610 | CH10 | 600 | 100 | |
| 820612 | CH12 | 600 | 100 | |
| 820608A | CH08 | 600 | 100 | |
| 820610A | CH10 | 600 | 100 | |
| 820612A | CH12 | 600 | 100 | |
| 820614A | CH14 | 600 | 100 |
4. Equivalences and Cross-References
Reference 820608/820610/820612 (and its variants with the suffix «A» in bag presentation) corresponds to the official catalogue of the manufacturer Medline and is distributed under the Cahnos SKU MDLP-DL67S without altering characters. Cahnos also markets these references with the MDL prefix (MDL820608, MDL820610, MDL820612, MDL820608A, MDL820610A, MDL820612A and MDL820614A). No 1:1 equivalence table validated by the manufacturer is available to cross-reference these codes with those of other suppliers; any substitution between brands in tenders must be validated field by field (material, length, diameter, sterility and presentation) with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Choose the catheter diameter according to the patient’s needs: the CH08 series is indicated for lower flow rates and the CH10, CH12 and CH14 series for higher flow rates within the recommended low-flow range (≤ 6 l/min). For services with continuous consumption, both presentations offer 600 units per box; references without a suffix are packed in inner boxes of 100 units, while references with the suffix «A» are supplied in bags of 100 units, facilitating stock management and rotation in ICU, hospitalisation wards and oxygen therapy. As a less intrusive alternative to the face mask, this nasal catheter can be complemented with nasal cannulas, tubes and accessories from the Medline oxygen therapy portfolio available in the Cahnos catalogue. For B2B volume conditions and budgets, contact our technical-commercial team.






Reviews