Description
1. Commercial Introduction
The 200 cm oxygen flow extension tube with female/female connection (Ref. OS/40) is the ideal accessory for completing and extending any oxygen therapy circuit: it is placed between the oxygen source (flowmeter, concentrator or cylinder) and the administration device (nasal cannula, mask or nebuliser), adding 200 cm of useful length without compromising flow stability. Made from flexible medical-grade materials with a firm, leak-proof connection, it is the professional and economical solution for hospitals, clinics, nursing homes and domiciliary oxygen therapy services, with a box of 100 units format designed for efficient stock management.
2. Technical Explanation
This tube acts as an extension of the oxygen administration circuit: it is placed between the main supply tube (the one coming from the flowmeter or, at home, from the oxygen concentrator) and the patient administration device. Its female/female configuration is designed to connect to a supply tube that already has a standard male end, allowing the total circuit length to be extended without the need for additional adapters.
The 200 cm length gives the patient greater freedom of movement during therapy, maintaining the integrity of the oxygen flow thanks to a constant internal lumen and a leak-proof connection that minimises losses. It is a single-use accessory, lightweight and easy to install, which helps reduce the risk of accidental disconnections and cross-contamination between patients. It is especially recommended for long-term oxygen therapy and when the patient needs to move around the room.
3. Technical Specifications
| Reference | OS/40 |
| Product type | Flow extension tube for oxygen therapy |
| Length | 200 cm |
| Connection | Female / Female |
| Function | Extension of the oxygen administration circuit |
| Units per box | 100 |
| Presentation | Box of 100 units |
Supplementary data for the flow extension tube family:
| Reference | Length | Connection | Units per box |
|---|---|---|---|
| OS/40 | 200 cm | Female / Female | 100 |
| OS/41 | 200 cm | Male / Female | 100 |
| OS/400 | 500 cm | Female / Female | 50 |
| OS/410 | 500 cm | Male / Female | 50 |
Compatibility: standard oxygen therapy systems with tube connectors 5–7 mm, flowmeters, oxygen concentrators, nasal cannulas, oxygen masks and nebulisers. Application: hospital, clinical and domiciliary.
4. Equivalences and Cross-References
The OS/40 extension tube belongs to the Cahnos catalogue oxygen circuit accessory family (OS/40, OS/41, OS/400 and OS/410). On the market there are connection lines and oxygen supply tubes from other manufacturers with comparable function, although with different length, connector type or configuration, so they are classified as comparable by category, not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Dahlhausen (P.J. Dahlhausen & Co. GmbH) | Safety connection line with 2 standard connectors (Sauerstoffverbindungsschlauch) | 01.000.02.002 | Comparable by category (not interchangeable 1:1) | 210 cm, two standard connectors, DEHP-free PVC, non-sterile, box of 50 units; length and packaging format different from OS/40. |
| Dahlhausen (P.J. Dahlhausen & Co. GmbH) | Safety connection line with 2 standard connectors (Sauerstoffverbindungsschlauch) | 01.000.02.003 | Comparable by category (not interchangeable 1:1) | 210 cm, two standard connectors, sterile, box of 50 units; connector configuration and presentation different from OS/40. |
| Hudson RCI® / Medline (Teleflex) | Star Lumen® supply tube (Oxygen Supply Tubing) | 41113 | Comparable by category (not interchangeable 1:1) | 210 cm (7 feet), standard end connector, five-channel internal lumen, box of 50 units; supply line, not extension, and of greater length. |
There is no equivalence table validated by the manufacturer for direct reference-to-reference substitution; consult with the technical department before using in a tender.
5. Selection tips and variants of interest
To choose the appropriate extension length, measure the actual distance between the oxygen source and the patient’s usual position:
- OS/40 (200 cm, female/female): this model. Recommended as an extension when the supply tube already ends in a standard male connector.
- OS/41 (200 cm, male/female): variant of the same length with male/female connection, useful for connecting directly to the source or to devices with female inlet.
- OS/400 (500 cm, female/female) and OS/410 (500 cm, male/female): long versions recommended for large rooms, mobile patients or circuits that need to go around the bed.
Always check the connector type of your oxygen source and administration device before placing the order. Use a new tube per patient to prevent cross-contamination and ensure traceability, and store the product in a cool, dry place. For B2B volume quotes and conditions, contact our technical-commercial team at Cahnos.