Description
1. Commercial Introduction
The 500 cm oxygen flow extension tube with male/female connection (Ref. OS/410) is the ideal accessory to complete and extend any oxygen therapy circuit: it securely connects the oxygen source (flowmeter, concentrator or cylinder) with nasal cannulas, face masks or nebulisers, adding 5 metres of useful length without compromising flow stability. Made from flexible medical-grade materials and with a firm, leak-proof connection, it is the professional and economical solution for hospitals, clinics, care homes and domiciliary oxygen therapy services, with a box format of 50 units designed for efficient stock management.
2. Technical Explanation
This tube acts as an extension of the oxygen administration circuit: it is inserted between the main supply tube (the one coming from the flowmeter or, at home, from the oxygen concentrator) and the patient administration device (nasal cannula, face mask or nebuliser). Its male/female configuration allows it to be coupled both to the source or to a supply tube with a female end (on the male side) and to devices with a standard inlet (on the female side), facilitating the extension of the run without the need for additional adapters when the circuit requires it.
The 5-metre length gives the patient greater freedom of movement during therapy, maintaining the integrity of the oxygen flow thanks to a constant internal bore and a leak-proof connection that minimises losses. It is a single-use, lightweight and easy-to-install accessory that helps reduce the risk of accidental disconnections and cross-contamination between patients. It is especially recommended for long-term oxygen therapy and when the patient needs to move around the room or around the bed.
3. Technical Specifications
| Reference | OS/410 |
| Product type | Flow extension tube for oxygen therapy |
| Length | 500 cm (5 m) |
| Connection | Male / Female |
| Function | Extension of the oxygen administration circuit |
| Units per box | 50 units |
| Presentation | Box of 50 units |
| Use | Individual, single patient |
| Application | Hospital, clinical and domiciliary |
Supplementary data for the flow extension tube family:
| Reference | Length | Connection | Units per box |
|---|---|---|---|
| OS/40 | 200 cm | Female / Female | 100 |
| OS/41 | 200 cm | Male / Female | 100 |
| OS/400 | 500 cm | Female / Female | 50 |
| OS/410 | 500 cm | Male / Female | 50 |
Compatibility: standard oxygen therapy systems with tube connectors of 5–7 mm, flowmeters, oxygen concentrators, nasal cannulas, oxygen face masks and nebulisers.
4. Equivalences and Cross-References
The OS/410 extension tube belongs to the oxygen circuit accessories family of the Cahnos catalogue (OS/40, OS/41, OS/400 and OS/410). On the market there are connection lines and oxygen supply tubes from other manufacturers with comparable function and length, although with a different type of connector, internal bore or configuration, so they are classified as comparable by category, not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Hudson RCI / Medline | Star Lumen supply tube | 1118P | Comparable by category (not interchangeable 1:1) | 420 cm, five-channel internal bore, standard terminal connector; box of 50 units. |
| Hudson RCI / Medline | Star Lumen supply tube | 1119P | Comparable by category (not interchangeable 1:1) | 760 cm, standard terminal connector; box of 25 units. Longer than the OS/410. |
| Dahlhausen (ICU range) | Safety connection line with 2 standard connectors | 01.000.02.014 | Comparable by category (not interchangeable 1:1) | 426 cm, two standard connectors, non-sterile, box of 50 units. |
| Dahlhausen (ICU range) | Safety connection line with 2 standard connectors | 01.000.02.018 | Comparable by category (not interchangeable 1:1) | 700 cm, two standard connectors, non-sterile, box of 25 units. |
There is no equivalence table validated by the manufacturer for direct reference-by-reference substitution; consult the technical department before use in tendering.
5. Selection tips and variants of interest
To choose the appropriate extension length, measure the actual distance between the oxygen source and the patient’s usual position: the OS/410 (500 cm, male/female) is the recommended option for large rooms, patients with mobility or circuits that require going around the bed.
- OS/410 (500 cm, male/female): this model. Versatile connection, useful for connecting directly to the source or to devices with a female inlet.
- OS/400 (500 cm, female/female): variant of the same length, ideal as an extension when the supply tube already ends in a standard male connector.
- OS/41 (200 cm, male/female) and OS/40 (200 cm, female/female): short versions for reduced runs or to adjust the circuit in compact spaces (box of 100 units).
Always check the connector type of your oxygen source and administration device before placing the order. Use a new tube per patient to prevent cross-contamination and ensure traceability, and store the product in a cool, dry place. For quotations and B2B volume conditions, contact our technical-commercial team at Cahnos.