Description
1. Product Presentation
The 1.5 m breathing tube (Ref. 53726) is the original replacement for the BIPAP R200 non-invasive ventilation devices (refs. 53720 and 53722), developed for the comfortable and effective treatment of sleep apnoea. It is a corrugated and flexible tube that connects the positive pressure device to the patient’s face mask, ensuring a stable airflow throughout the night. A class II A medical device, supplied individually, it is the spare part that ensures treatment continuity and extends the life of your equipment.
2. Technical explanation
The BIPAP R200 devices (53720 and 53722) are positive airway pressure (PAP) systems used in CPAP, APAP and BiPAP modes to prevent upper airway collapse during sleep. The 1.5 m breathing tube is part of the patient circuit: it carries pressurised air from the flow generator to the face mask and, in configurations with a humidifier, acts as a gas conduit. Its corrugated and flexible design maintains circuit patency against kinking and gives the patient freedom of movement during rest. As a spare part, correct installation and periodic replacement are key to maintaining circuit seal, avoiding leaks and preserving the accuracy of the pressure parameters recorded by the device.
3. Technical Specifications
This replacement is compatible with the BIPAP R200 devices with refs. 53720 and 53722. Product data according to the manufacturer’s official catalogue:
Product data
| Manufacturer | GIMA |
|---|---|
| Reference | 53726 |
| Length | 1.5 m |
| Compatibility | BIPAP R200 devices (53720, 53722) |
| Use | Spare part (spare) |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
4. Equivalences and Cross-References
Ref. 53726 corresponds to distributor code G-53726 and appears in European catalogues as “breathing hose 1.5 m for 53720, 53722 – spare” / “tubo respiratorio 1.5 m per 53720, 53722 – ricambio”. It is the official replacement for the BIPAP R200 therapy systems: ref. 53720 (CPAP/APAP modes) and ref. 53722 (multimodal configuration with S, S/T and T modes). No direct equivalence table with tubes from other manufacturers has been found in reliable sources; as compatibility depends on connector diameter and the humidification system, it is recommended to check the technical data sheet of each brand before replacing the circuit. For cross-references or compatibilities, consult our technical-commercial department.
5. Selection tips and variants of interest
Before replacing the tube, confirm your device model: ref. 53720 corresponds to the system with CPAP and APAP modes, while 53722 adds the advanced S, S/T and T modes. This 1.5 m replacement is the standard recommended length for home use; in installations where the distance between the device and the bed is greater, consider the placement of the device (bedside table or stand) to avoid tube kinking. Periodically check the condition of the conduit (cracks, connector looseness, debris) and replace it according to the manufacturer’s instructions and the hygiene protocol of the centre or home therapy service. For large orders you can request a quote: contact Cahnos for terms, delivery times and technical advice.




Reviews
There are no reviews yet.