We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Ophthalmic Knife (Keratome) Straight Sharp Point 6.2 mm for Incision Widening in Intraocular Lens (IOL) Surgery – Ref. P-916201

45,00 €

Ophthalmic knife (keratome) with straight sharp point of 6.2 mm for the controlled widening of the incision in intraocular lens (IOL) surgery. Made of high-quality surgical steel, it guarantees clean, self-sealing and reproducible incisions, with minimal tissue distortion and induction of astigmatism. Single-use instrument: maximum edge and zero risk of cross-contamination in every procedure. Presentation in box of 6 units; made-to-order supply with an estimated delivery time of 6 to 8 weeks. Reference P-916201. Ideal for hospitals, ophthalmology clinics and surgical centres.

Available on back-order

International shipping. Import duties and taxes are payable by the recipient.

Reference
P-916201

Description

1. Product Presentation

The Ophthalmic Knife (Keratome) with Straight Sharp Point of 6.2 mm, reference P-916201, is a precision micro-instrument designed for the controlled widening of the incision in intraocular lens (IOL) surgery. Made of high-quality surgical steel, it offers a homogeneous and durable cutting edge that allows clean, controlled and reproducible cuts, optimising the surgical outcome and reducing the risk of postoperative complications. It is the reliable choice for hospitals, ophthalmology clinics and surgical centres that value repeatability and safety in every step of the procedure.

2. Technical explanation of the procedure

Straight sharp-point knives or keratomes are used to widen the entry corneal or scleral incision previously created with the phacoemulsification knife, allowing access and implantation of the intraocular lens (IOL). The straight geometry with a sharp point facilitates controlled advancement through the corneal tunnel, while the blade width of 6.2 mm provides the largest opening in the widening range, necessary for the introduction of intraocular lenses or large-diameter injector systems. The precision edge generates a progressive, clean and self-sealing cut, with minimal tissue distortion and induction of astigmatism, favouring wound watertightness and faster patient recovery. As it is a single-use instrument, the risk of cross-contamination is eliminated and an intact edge is guaranteed in every procedure.

3. Technical Specifications

The main technical specifications of the product are detailed below:

Parameter Specification
Type Ophthalmic blade (keratome) with straight sharp tip
Blade width 6.2 mm
Geometry Straight, sharp point
Material High-quality surgical steel
Application Incision widening in intraocular lens (IOL) surgery and professional ophthalmic microsurgery
Use Disposable, single-use
Compatibility Hospitals, clinics and ophthalmic surgical centres
Presentation Box of 6 units
Delivery time 6 to 8 weeks (made to order)
Reference P-916201

Range of straight sharp knives for incision widening in intraocular lens surgery:

Reference Blade width Description
P-914001 4.0 mm Straight sharp point for IOL widening
P-915201 5.2 mm Straight sharp point for IOL widening
P-915501 5.5 mm Straight sharp point for IOL widening
P-916001 6.0 mm Straight sharp point for IOL widening
P-916201 6.2 mm Straight sharp point for IOL widening (current data sheet)

4. Equivalences and Cross-References

This knife belongs to the family of straight sharp-point keratomes for incision widening in intraocular lens surgery (series P-914xxx / P-915xxx / P-916xxx from Cahnos). Its function is comparable to that of straight incision-widening knives from leading manufacturers in the ophthalmic field (Katena, Storz / Bausch + Lomb, Malosa, Sharpoint from Surgical Specialties, Microtrack Surgicals and similar), although the exact equivalence of measurements and geometry must be confirmed according to the surgeon’s technique. In the international market, references from the IOL extension keratome family such as M905261 (5.2 mm) and M905561 (5.5 mm) from Microtrack Surgicals correspond to sizes in this same range. Consult our technical-commercial team to validate the most suitable reference for your surgical protocol.

5. Selection tips and variants of interest

Select the blade width according to the diameter of the intraocular lens and the planned incision: 4.0 mm (P-914001) for reduced access, 5.2 mm (P-915201) and 5.5 mm (P-915501) for intermediate sizes, and 6.0 mm (P-916001) or 6.2 mm (P-916201) when the greatest widening is required, for example for large-diameter lenses or techniques that demand a wide opening. If you prefer an angled approach, consider the variants P-914061 (4.0 mm angled 45°), P-915561 (5.5 mm angled 45°) or P-916061 (6.0 mm angled 45°). To complete the surgical set, combine this knife with the straight phacoemulsification keratomes from the P-912xxx series and with the double-bevel variants. As this is a made-to-order supply, we recommend planning purchases in advance: the delivery time is 6 to 8 weeks, in a box of 6 units.

Additional information

Reference

P-916201

Blade width

6.2 mm

Geometry

Straight, sharp point

Tip type

Sharp

Material

High-quality surgical steel

Application

Incision widening in intraocular lens (IOL) surgery

Use

Disposable, single-use

Presentation

Box of 6 units

Reviews

There are no reviews yet.

Be the first to review “Ophthalmic Knife (Keratome) Straight Sharp Point 6.2 mm for Incision Widening in Intraocular Lens (IOL) Surgery – Ref. P-916201”

Your email address will not be published. Required fields are marked *