We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Ophthalmic Keratome (Sharp-Point) 45° Angled, 19 Gauge, with 2.8 mm Blade for Phacoemulsification and Corneal Incision – Ref. P-912861

45,00 €

The 45° Angled Sharp-Point Ophthalmic Keratome, 19 Gauge, with 2.8 mm Blade is a precision keratome manufactured from high-quality surgical steel, designed to create clear, clean, self-sealing corneal incisions in cataract phacoemulsification surgery and in preparing the incision for intraocular lenses (IOL). Its 45° angulation improves ergonomics and the angle of attack in reduced surgical fields, while the sharp point ensures controlled penetration and sharp edges with minimal corneal deformation and less induced astigmatism. Ideal for hospitals, ophthalmology clinics and surgical centres. Presentation in a box of 6 units, supplied to order with an estimated delivery time of 6 to 8 weeks. Reference P-912861.

Available on back-order

International shipping. Import duties and taxes are payable by the recipient.

Reference
P-912861

Description

1. Product Presentation

The 45° Angled Sharp-Point Ophthalmic Keratome, 19 Gauge, with 2.8 mm Blade (Ref. P-912861) is a precision micro-instrument designed for anterior segment ophthalmic microsurgery. Manufactured from high-quality surgical steel, it offers an optimal combination of rigidity, lasting sharpness and absolute control of the surgical manoeuvre, ensuring clean, safe and reproducible incisions at every step of the procedure. It is the reliable choice for hospitals, ophthalmology clinics and surgical centres that value accuracy, repeatability and safety in the operating theatre, with excellent value for money when purchased by the box of 6 units.

2. Technical explanation

Angled sharp-point keratomes are mainly used to create the clear corneal entry incision in cataract phacoemulsification surgery, as well as to prepare and widen the incision for intraocular lens (IOL) implantation. The 45° angulation separates the handle from the cutting area, facilitating the correct angle of attack on the cornea and allowing the blade to be kept in a stable plane during the incision, even with limited eyelid opening or angled access.

The sharp point facilitates controlled initial penetration and progressive advancement through the corneal tunnel, while the 2.8 mm blade width provides the ideal opening for small, controlled incisions. The result is a wound with clean, self-sealing edges, minimal tissue distortion and reduced induced astigmatism, which promotes anterior chamber stability, reduces postoperative leakage and accelerates patient recovery.

3. Technical Specifications

The main technical specifications of the product are detailed below:

Type Ophthalmic blade (keratome) with sharp point angled 45°
Tip type Sharp point
Angulation 45°
Gauge 19
Blade width 2.8 mm
Material High-quality surgical steel
Application Phacoemulsification, clear corneal incision and incision preparation for intraocular lenses (IOL)
Compatibility Hospitals, clinics and ophthalmic surgical centres
Presentation Box of 6 units
Supply Made to order, estimated delivery time 6 to 8 weeks
Reference P-912861

Variants of the family of sharp-pointed knives angled 45° (19 gauge):

Reference Blade width Description
P-912361 2.3 mm Sharp point, 45° angled, 19 gauge
P-912561 2.5 mm Sharp point, 45° angled, 19 gauge, for IOL widening
P-912661 2.65 mm Sharp point, 45° angled, 19 gauge
P-912861 2.8 mm Sharp point, 45° angled, 19 gauge (this datasheet)
P-912961 3.0 mm Sharp point, 45° angled, 19 gauge
P-912968 3.0 mm Sharp point, 45° angled, 19 gauge, double bevel
P-913268 3.2 mm Sharp point, 45° angled, 19 gauge, double bevel

4. Equivalences and Cross-References

This keratome belongs to the family of angled sharp-point keratomes for corneal incision in phacoemulsification. Its function and geometry are comparable to those of angled clear corneal incision keratomes from leading ophthalmic manufacturers such as Katena, Storz / Bausch + Lomb, Sharpoint blades from Surgical Specialties (Corza Medical), Malosa, Alcon, KAI Medical, Unique Technologies, Aktive and Alchimia, although the exact equivalence of gauge, blade width and angle should be confirmed according to each surgeon’s technique.

In the Cahnos catalogue, its closest references by gauge and geometry are P-912561 (45° angled, 2.5 mm), P-912661 (2.65 mm) and P-912961 (3.0 mm), as well as the double-bevel version P-912968 (3.0 mm) for a more symmetrical cut. For incision widening in intraocular lens (IOL) surgery, the P-915xxx and P-916xxx series are also available.

5. Selection tips and variants of interest

Select the blade width according to the intended incision plan: 2.3 to 2.8 mm for reduced access and microincisions (P-912361, P-912561, P-912661, P-912861), 3.0 mm as the standard size for clear corneal incision in phacoemulsification (P-912961) and 3.2 mm (P-913268) when a slightly larger access is required. If you prefer a symmetrical edge, consider the double-bevel versions P-912968 and P-913268; for IOL incision widening, consider the P-915xxx and P-916xxx series.

The 45° angulation is especially recommended in surgeries with limited eyelid opening or angled access, as it improves manoeuvrability without straining the surgeon’s wrist. As this product is supplied to order with a delivery time of 6 to 8 weeks, we recommend planning the purchase by the box of 6 units in advance to ensure availability in the operating theatre. For specific volumes or protocols, consult our technical-commercial team, who will advise you on the most suitable reference for your surgical practice.

Additional information

Reference

P-912861

Product type

Ophthalmic blade (keratome) with sharp point angled 45°

Tip type

Sharp

Angulation

45°

Gauge

19

Blade width

2.8 mm

Material

High-quality surgical steel

Application

Phacoemulsification, clear corneal incision and incision preparation for intraocular lenses (IOL)

Compatibility

Hospitals, clinics and ophthalmic surgical centres

Presentation

Box of 6 units

Reviews

There are no reviews yet.

Be the first to review “Ophthalmic Keratome (Sharp-Point) 45° Angled, 19 Gauge, with 2.8 mm Blade for Phacoemulsification and Corneal Incision – Ref. P-912861”