We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Ophthalmic Keratome Blade Sharp Tip Angled 45° 19 Gauge (Double Bevel) 3.0 mm for Phacoemulsification and IOL Incision

45,00 €

Ophthalmic keratome blade 3.0 mm with sharp tip, 45° angulation and double bevel, manufactured from high-quality surgical steel. Its 19 gauge and symmetrical edge allow clear, clean and self-sealing corneal incisions in phacoemulsification and in incision preparation for intraocular lenses, with minimal tissue trauma and excellent anterior chamber stability. Ideal for hospitals, ophthalmic clinics and surgical centres seeking precision, repeatability and safety in every procedure. Supplied in a box of 6 units, on order with a delivery time of 6 to 8 weeks. Reference P-912968.

Available on back-order

International shipping. Import duties and taxes are payable by the recipient.

Reference
P-912968

Description

The Ophthalmic Blade Sharp Tip Angled 45° 19 Gauge (Double Bevel) 3.0 mm is a precision keratome designed for surgeons who demand maximum control in anterior segment ocular microsurgery. Manufactured from high-quality surgical steel, this micro-instrument guarantees clean, controlled and self-sealing incisions, optimising surgical outcomes and reducing the risk of postoperative complications. It is the reliable choice for hospitals, ophthalmic clinics and surgical centres that value repeatability and safety at every step of the procedure.

Angled sharp-tip blades or keratomes are mainly used to create the clear corneal entry incision in cataract phacoemulsification surgery, as well as to prepare and widen the incision for intraocular lens (IOL) implantation. The 45° angulation separates the handle from the cutting area, facilitating the correct angle of attack on the cornea and allowing the blade to be kept in a stable plane during the incision. The sharp tip favours controlled initial penetration, while the double-bevel sharpening (on both faces) produces a symmetrical, uniform cut with less resistance to advancement and sharp incision edges. The result is a self-sealing wound with minimal tissue distortion and less induced astigmatism, which favours anterior chamber stability, reduces postoperative leakage and speeds up patient recovery. As a single-use instrument, the risk of cross-contamination is eliminated and an intact edge is guaranteed in every procedure.

Technical specifications

The main technical specifications of the product are detailed below:

Characteristic Specification
Type Ophthalmic blade (keratome) with sharp point angled 45°
Blade width 3.0 mm
Tip Sharp
Bevel Double bevel (sharpened on both sides)
Gauge 19
Angulation 45°
Material High-quality surgical steel
Application Phacoemulsification, clear corneal incision and incision preparation for intraocular lenses (IOL)
Use Disposable, single-use
Compatibility Hospitals, clinics and ophthalmic surgical centres
Presentation Box of 6 units
Delivery time 6-8 weeks
Reference P-912968

Range of sharp angled double bevel blades for phacoemulsification:

Reference Blade width Description
P-912868 2.8 mm Sharp point angled 45° 19 gauge (double bevel)
P-912968 3.0 mm Sharp point angled 45° 19 gauge (double bevel), current data sheet
P-913268 3.2 mm Sharp point angled 45° 19 gauge (double bevel)

Equivalences and cross-references

This blade belongs to the family of angled sharp-tip double-bevel keratomes for corneal incision in phacoemulsification. Its function is comparable to that of the angled clear corneal incision blades from leading manufacturers in the ophthalmological field, such as Katena, Storz / Bausch + Lomb, Sharpoint blades from Surgical Specialties (Corza Medical), KAI Medical and Malosa, although the exact equivalence of dimensions, gauge and geometry must be confirmed according to the surgeon’s technique. In the Cahnos catalogue, the closest references are P-912868 (2.8 mm) and P-913268 (3.2 mm), from the same 45° 19-gauge angled double-bevel family; it is complemented by the straight double-bevel (P-912808) and straight sharp-tip (P-912901) blades, as well as the spoon-type miniature blades (P-6820, P-6821, P-6821E).

Selection tips and variants of interest

Select the blade width according to the planned incision: 2.8 mm (P-912868) for reduced access, 3.0 mm as the standard size for clear corneal incision in phacoemulsification (P-912968, current data sheet) and 3.2 mm (P-913268) when a slightly larger access is required. The 45° angle is especially useful in surgeries with limited eyelid opening or angled access. If you prefer a straight approach with double bevel, consider the P-912808, or the P-912901 if you need a straight sharp tip; for micro-incisions with a spoon-type edge, consider the P-6820, P-6821 and P-6821E variants. For incision widening in intraocular lens (IOL) surgery, the P-915xxx and P-916xxx series are also available. As this product is supplied on order with a delivery time of 6 to 8 weeks, we recommend planning the order by box of 6 units in advance to ensure availability in the operating theatre. For specific volumes or protocols, consult our technical-commercial team, who will advise you on the most suitable reference for your surgical practice.

Additional information

Product type

Ophthalmic blade (keratome) with sharp point angled 45°

Blade width

3.0 mm

Angulation

45°

Gauge

19

Tip

Sharp

Bevel

Double bevel

Material

High-quality surgical steel

Application

Phacoemulsification, clear corneal incision and incision preparation for intraocular lenses (IOL)

Use

Disposable, single-use

Compatibility

Hospitals, clinics and ophthalmic surgical centres

Presentation

Box of 6 units

Reference

P-912968

Reviews

There are no reviews yet.

Be the first to review “Ophthalmic Keratome Blade Sharp Tip Angled 45° 19 Gauge (Double Bevel) 3.0 mm for Phacoemulsification and IOL Incision”

Your email address will not be published. Required fields are marked *