Description
1. Commercial Introduction
In nuclear medicine and radiopharmacy services, the management of solid radioactive waste is a critical link in daily radiological safety. The Shielded Trolley-Container RadWaste Move (SKU: CAH-RWM-60-20) meets this need with a 2-in-1 solution: it allows collection, temporary storage and transfer of low and medium energy waste directly from the point of generation, whether it be the injection room, radiopharmacy, quality control or cell labelling area. Manufactured within the RADIOPROTECH waste management range and distributed by Cahnos, it combines biological shielding of 20 mm lead, a 60 litre capacity and a sliding drawer filling system that minimises staff exposure without compromising the agility of the radiation-protected workflow.
2. Technical explanation of the equipment
The RadWaste Move acts as an intermediate mobile containment point between the waste generation site and its final removal. Its lead shielding attenuates the gamma radiation emitted by the most common low and medium energy radiopharmaceuticals in nuclear medicine, such as technetium-99m (Tc-99m, 140 keV) or iodine-131 (I-131), applying the ALARA principle (keeping doses as low as reasonably achievable).
The sliding drawer opening system allows fast, safe daily filling: the drawer slides to deposit the waste and closes immediately, limiting the operator’s exposure time during each operation. Four large-diameter wheels ensure mobility and manoeuvrability even with heavy loads, moving easily over technical or hospital plastic floors. The unit combines the containment of a shielded container with the versatility of a transport trolley in a single robust and stable unit, designed for intensive use in controlled areas.
3. Technical Specifications
The Shielded Trolley-Container RadWaste Move is configured according to two parameters: biological protection and capacity. The reference CAH-RWM-60-20 corresponds to the 60 litre version with 20 mm lead shielding. Its main specifications are detailed below:
| Characteristic | Specification |
| Model / Family | RadWaste Move (RADIOPROTECH radioactive waste management range) |
| Reference (SKU) | CAH-RWM-60-20 |
| Main function | Collection, temporary storage and transport of solid radioactive waste |
| Biological protection | 5, 10 or 20 mm lead (configurable) |
| Shielding of this version | 20 mm lead |
| Capacity | 30 or 60 litres (this version: 60 litres) |
| Opening system | Sliding drawer for fast, safe daily filling |
| Mobility | 4 large-diameter wheels, suitable for heavy loads on technical or hospital plastic floors |
| Energy range | Low and medium energy (radiopharmaceuticals such as Tc-99m, I-131) |
| Applications | Injection rooms, radiopharmacy, quality control, cell labelling areas |
| Scope of use | Nuclear medicine, radiopharmacy and laboratories with radioisotopes |
Table of available configurations for the RadWaste Move family:
| Parameter | Options |
| Biological protection | 5 mm / 10 mm / 20 mm lead |
| Capacity | 30 / 60 litres |
| Opening system | Sliding drawer for daily filling |
| Mobility | 4 large-diameter wheels |
4. Equivalences and Cross-References
The Shielded Trolley-Container RadWaste Move corresponds to the shielded trolley-container of the RADIOPROTECH radioactive waste management range, a leading European manufacturer in radiation protection distributed by Cahnos, in its mobile 60 litre and 20 mm lead configuration. Within the Cahnos catalogue, the functionally equivalent solutions for mobile radioactive waste management are the Medi 64 shielded bins on wheels (CAH-LP00034045 and CAH-LP00034046), which cover the same collection and transfer workflow in nuclear medicine and radiology.
As a fixed counterpart from the same manufacturer, the RadWaste shielded container (CAH-CBR-60-20, 60 litres and 20 mm lead) completes the containment circuit in injection rooms and radiopharmacy; the NeedleShield container (CAH-CBA-15) covers the fraction of radioactive sharps waste compatible with OPCT trays; and the PRA10 (CAH-LPPRA10) and PRA3 (CAH-LPPRA3) shielded containers offer lower shielding alternatives. In the international market, the most direct comparison category is shielded bins on wheels and waste transport trolleys for nuclear medicine from European manufacturers such as Lemer Pax. Consult our technical-commercial team to verify specific equivalences according to your facility and waste volume.
5. Selection tips and variants of interest
To select the most suitable RadWaste Move configuration, consider the following criteria:
- Energy level of the radiopharmaceutical: for low-energy isotopes, 5 or 10 mm lead shielding may be sufficient; for medium energy or higher workloads, the 20 mm lead of this reference is recommended. The opinion of the radiation protection service is decisive.
- Waste volume: choose the 30 litre capacity for low-throughput generation points or the 60 litre capacity for injection rooms and radiopharmacy with medium or high activity.
- Routes and surfaces: its four large-diameter wheels are ideal for moving heavy loads along corridors, lifts and technical or hospital plastic floors.
- Complementarity: combine this trolley-container with the fixed shielded RadWaste container (CAH-CBR-60-20), the Medi 64 shielded waste bins (CAH-LP00034045 and CAH-LP00034046) or the Medisharp needle containers (CAH-LP00034047 and CAH-LP00034048) for a complete radiation-protected workflow, from the injection room to the final disposal of the material.
For more information on bespoke configurations, technical documentation or special conditions for tenders, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.