We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Shielded Transmural Window PassShield CAH-VT-2PB – Safe Material Pass-Through between Rooms for Nuclear Medicine and Radiopharmacy (2 mm Lead, Low/Medium Energy)

Price on request

Lead-lined through-wall hatch in stainless steel with 2 mm lead, designed for the safe transfer of material, vials and radioactive sources between adjacent rooms in nuclear medicine and radiopharmacy services. Manufactured under the ALARA principle, it allows products to be transferred without opening the containment barrier, with configurable opening direction, standard version or with overpressure system, and locking and lead glass options for access control and viewing. An ideal structural shielding solution for controlled areas requiring basic radiation protection without compromising daily operability. Reference CAH-VT-2PB.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CAH-VT-2PB

Description

1. Commercial Introduction

The PassShield Lead-Lined Through-Wall Hatch (SKU: CAH-VT-2PB) is the professional solution for transferring material, vials and radiopharmaceutical preparations between two adjacent spaces without compromising the radiation protection of the controlled area. Specifically designed for nuclear medicine, radiopharmacy and radiation-controlled zones, this pass-through hatch maintains workflow continuity between the radiopharmacy, the injection room and the scanning rooms, eliminating unnecessary movements and reducing staff exposure.

Its stainless steel construction with 2 mm lead shielding makes it a robust, hygienic and easily decontaminated option, designed to integrate into the furniture and structural barriers of your facility without compromising operability.

2. Technical explanation of the equipment

The through-wall hatch acts as an intermediate physical barrier separating two rooms while maintaining the room’s radiological shielding, while allowing the passage of small and medium-sized material through a transfer compartment. The protective core consists of a 2 mm lead shield, suited to low and medium energy radiopharmaceuticals, which attenuates direct and scattered gamma radiation in line with the ALARA principle (keeping doses as low as reasonably achievable).

The system incorporates a door whose opening direction is configurable according to the space layout, avoiding the need to physically cross the barrier with the material. It is available in a standard version or with an overpressure system for facilities with air flow and environmental control requirements, and can be completed with an interlocking system that prevents simultaneous opening of both sides — an essential condition for maintaining containment integrity — as well as with a lead glass window that allows viewing the interior without reducing protection. Its stainless steel surface ensures durability, mechanical resistance and easy decontamination after handling sources.

3. Technical Specifications

Characteristic Detail
SKU CAH-VT-2PB
Main material Stainless steel
Lead thickness 2 mm
Energy type Low/Medium
Applications Nuclear medicine, radiopharmacy, controlled areas
Parameter Specification
Function Material transfer between adjacent rooms while maintaining shielding
Radiological shielding 2 mm lead (low/medium energy)
Opening configuration Door opening direction configurable according to the space
Locking system Optional: prevents unwanted simultaneous openings
Viewing window Optional, in lead glass
Versions Standard or with overpressure system
Maintenance Surfaces that are easy to clean and decontaminate

4. Equivalences and Cross-References

The PassShield Lead-Lined Through-Wall Hatch is functionally aligned with the shielded material pass-through systems (passe-plat / transfer hatches) that leading radiation protection manufacturers such as Lemer Pax, Von Gahlen or Radioprotech incorporate into their nuclear medicine barriers, configured with lead thicknesses from 2 to 5 mm depending on the radiopharmaceutical’s energy spectrum. In the Cahnos catalogue, this solution is complemented by the UnderShield Under-Table Lead-Lined Storage (CAH-ABM-20-900) for source custody, the SC10 Lead-Lined Syringe Holder (CAH-LPSC10) and the Crocobox-type case (CAH-LM00038013) for transporting syringes and vials, as well as the RadCase Lead-Lined Case (CAH-MB-15-AF) for low and medium energy applications with configurable shielding. To confirm exact dimensional and thickness equivalences with other manufacturers, our technical-commercial team can verify compatibility with your construction or controlled area renovation project.

5. Selection tips and variants of interest

To choose the right configuration for your through-wall hatch, assess the type of radionuclide and its energy: the 2 mm lead shielding of the CAH-VT-2PB is indicated for low and medium energy emitters; if your workflow includes high-energy radiopharmaceuticals or high activities, consult the versions with greater lead thickness in the same family. Select the opening direction based on the flow of staff and material, and activate the interlocking system if you want to guarantee that both sides are never open simultaneously, always maintaining containment integrity. If your radiopharmacy works with overpressure rooms or differential air flow requirements, opt for the version with an overpressure system. Complete the installation with the optional lead glass window to supervise the interior without opening the hatch, and combine this solution with shielded containers, syringe holders and source storage for a comprehensive radiation protection strategy, from reception to the passage between rooms.

Additional information

Lead thickness

2 mm

Energy type

Low/Medium

Application

Nuclear medicine, radiopharmacy, controlled areas

Opening configuration

Configurable opening direction

Locking system

Optional (prevents simultaneous openings)

Lead glass window

Optional

Versions

Standard or with overpressure system

Protection principle

ALARA

Material

Stainless steel