Description
InjectShield Shielded Injection Shield for Radiation Protection – SKU CAH-EI-30-RG
1. Professional radiation protection during radiopharmaceutical administration
In nuclear medicine and radiopharmacy services, the administration of radiopharmaceuticals is one of the moments of greatest occupational exposure for healthcare professionals. The InjectShield Shielded Injection Shield is placed between the operator and the radioactive source during injection and during immediate contact with the patient after administration, significantly reducing the dose received in the hands, trunk and extremities. A mobile, ergonomic biological barrier that is easily integrated into injection rooms, PET units and nuclear medicine examination areas.
2. Technical explanation of the equipment
The InjectShield acts as a biological barrier against high-energy gamma photons (such as the 511 keV characteristic of PET radioisotopes), whose attenuation requires materials with a high atomic number. It therefore incorporates a lead layer with a configurable thickness between 10 and 30 mm, selectable according to the radionuclide, the activity handled and the area of use, following the ALARA principle (keeping the dose as low as reasonably achievable). The large leaded glass window ensures full visibility of the procedure without compromising attenuation, while the height-adjustable stainless steel shelf (three positions) adapts the shield to the operator’s height and the injection point. The mobile chassis, with small or large wheels, allows clearance under beds and injection chairs, and the folding step improves comfort during prolonged procedures. Optionally, a remote injection control arm can be incorporated, which increases the operator-source distance and further minimises exposure. For PET/MR environments, a non-magnetic aluminium version is available.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Model | InjectShield Shielded Injection Shield |
| SKU / Reference | CAH-EI-30-RG |
| Main function | Radiation protection during radiopharmaceutical administration and post-injection contact with the patient |
| Biological protection | Configurable lead from 10 to 30 mm (ALARA principle) |
| Viewing window | Wide lead glass window |
| Shelf | Stainless steel, height-adjustable (3 positions) |
| Mobility | Small or large wheels; chassis with clearance under beds and chairs |
| Ergonomics | Folding step for prolonged use |
| Optional accessory | Remote injection control arm |
| Special version | Non-magnetic version available for PET/MR (100% aluminium) |
| Scope of use | Nuclear medicine, radiopharmacy, injection room and PET units |
Table of available configurations:
| Parameter | Options |
|---|---|
| Biological protection | 10 / 15 / 20 / 30 mm of lead depending on area and activity |
| Wheels | Small or large |
| Materials | Stainless steel and lead; non-magnetic version in 100% aluminium |
| Injection control | Standard manual / optional remote arm |
4. Equivalences and Cross-References
The InjectShield corresponds to the functional family of the PET injection shield from RADIOPROTECH, a leading European manufacturer of radiation protection distributed by Cahnos, in its lead biological protection configuration with viewing window and adjustable shelf (direct equivalent of the variant that gives rise to SKU CAH-EI-30-RG: 30 mm of lead). It shares its field of application with the height-adjustable mobile protection shield with lead glass window (CAH-LPBPP30 HV), intended for preparation and injection rooms, and with the TableShield shielded table shield (CAH-EM-30-V60) for benchtop workstations. In the radiation-protected workflow, it is complemented by syringe shields such as the Easysqueeze shielded shield (CAH-LP00008664), vial shields (CAH-BVS-MIX-BME and CAH-101.000.20X.000) and the UnderShield shielded under-table storage (CAH-ABM-20-900). For beta-emitting radiopharmaceuticals, the specific injection alternative is the BetaShield Move shield (CAH-BSM-10-BE).
5. Selection tips and variants of interest
To choose the optimal configuration, assess the energy spectrum and activity of the radiopharmaceuticals you administer: 10 mm thicknesses for moderate activities and low-energy emitters, and 20 to 30 mm for high-energy emitters such as PET. Always confirm the shielding with your radiation protection service based on the area’s design dose calculation. If you work in PET/MR rooms, request the non-magnetic aluminium version. Consider the remote injection arm to increase the operator-source distance in high-activity scenarios, and large wheels if you need to move frequently between rooms. Complete your comprehensive strategy with syringe shields, vial shields and table shields from the same range. Request a personalised quote from our technical-commercial team to adapt the configuration to your workstation.