Introduction
The RadWork Shield Open Workstation (SKU: CAH-PTA-50-30VP) is the perfect ally for radiopharmacies and nuclear medicine departments that need to prepare radiopharmaceuticals with total safety, comfort and workflow efficiency. Designed by Cahnos in an open configuration, this lead-shielded workstation protects the operator during isotope handling without isolating them from the workflow, enabling agile, ergonomic preparation with full visibility of the operation. A robust, functional investment that is easy to integrate into new laboratories or into departments looking to upgrade their preparation stations to current radioprotection standards.
Technical explanation of the equipment
The RadWork Shield is an open workstation shielded on four sides, specifically designed for the safe preparation of radiopharmaceuticals in nuclear medicine environments. Its biological barrier is provided by a 50 mm lead body that effectively attenuates the radiation emitted by vials and syringes during preparation, dosing and fractionation of the activity.
The key component of the assembly is its laterally sliding front work shield, which combines 30 mm of lead with a 60 mm lead-glass window: the operator thus achieves excellent biological protection without losing visual control of the manipulation, improving ergonomics and reducing fatigue during high-workload shifts. Being an open configuration, it facilitates direct access to materials and free movement of hands and utensils, unlike closed cells with glove ports.
Its compact design is sized to pass through standard doorways, greatly simplifying installation and avoiding structural modifications in the laboratory. The entire assembly is built with high-quality materials and durable finishes, designed for intensive use and to withstand the cleaning and decontamination protocols common in radiopharmacy.
Technical specifications
The reference specifications for the RadWork Shield open workstation from the Cahnos radioprotection range are detailed below:
| Characteristic | Detail |
|---|---|
| Reference (SKU) | CAH-PTA-50-30VP |
| Product type | Open shielded work station for nuclear medicine |
| Configuration | Open, with laterally sliding front work shield |
| Work station body shielding | 50 mm lead |
| Front shield shielding | 30 mm of lead |
| Front window | 60 mm lead glass |
| Perimeter protection | Shielded on 4 sides |
| Available configurations | 40 or 50 mm of lead in the work station body, depending on model |
| Intended use | Preparation of radiopharmaceuticals in radiopharmacy and nuclear medicine |
| Installation | Dimensions suitable for passing through standard doors |
The model nomenclature CAH-PTA-50-30VP indicates the lead-shielded configuration of this unit: 50 mm of lead in the workstation body and 30 mm in the front shield with 60 mm of lead glass. It is recommended to confirm with the Cahnos technical-commercial team the exact dimensions and customisation options according to the layout of your room.
Equivalences and cross-references
This open workstation belongs to the family of open-configuration workstations from the European manufacturer Radioprotech (MRP Medical Systems), a reference catalogue in which the open workstation shielded on four sides with sliding shield and biological protections of 40–50 mm of lead in the body and 30 mm of lead with 60 mm of lead glass in the shield constitutes one of the standard configurations for radiopharmaceutical preparation.
In Cahnos’s own catalogue, it shares its field of application with the BioSafe II Semi-Open Shielded Microbiological Cabinet (ref. CAH-CSM-II-10PB), which reproduces the same concept of a sliding front shield on a shielded structure, and with the RadSafe Pro Shielded Cell (ref. CAH-CB-20/50-2G) for closed configurations with glove ports. For manual preparation in a hot cell, the complementary alternatives are the Asypharma compact Class A cell (ref. CAH-LEM17860) and the PSMEB Class A cabinet (ref. CAH-LEM5-900), while the SynthShield Pro cell (ref. CAH-SSP-AE) covers high-energy PET production. In the international market, its functionality is similar to the preparation stations and cells from Lemer Pax, Comecer and Tema Sinergie, which use equivalent lead thicknesses (30–50 mm) and lead-glass windows with a high lead equivalent.
Selection tips and variants of interest
- Choose the body thickness according to the energy and activity you will handle: the 50 mm model (CAH-PTA-50-30VP) is the maximum protection option in the range, while the 40 mm configuration is sufficient in many departments with low- and medium-energy isotopes and moderate workloads.
- Assess the ergonomic workflow: the sliding front shield allows working with both hands and keeping the material in view; if your protocol requires full containment, closed cells with glove ports (RadSafe Pro, Asypharma) are the alternative.
- Plan the installation: check the width of the laboratory access points; the RadWork Shield design is intended to pass through standard doors, reducing lead times and civil works.
- Complete the radioprotection line with bench shields, vial and syringe protectors, shielded waste containers and mini source storage units (SafeStore) available from Cahnos for a safe workflow from start to finish.
- Consult our technical-commercial team to confirm dimensions, integration with worktops and accessories, as well as a formal quotation according to the needs of your facility.





Reviews