Description
Permanent strength for high-demand surgery
The stainless steel suture Premisut Prime USP 6 is the reference choice for closures that must withstand the greatest mechanical tension: sternal fixation after sternotomy, abdominal wall closure, hernia repair and orthopaedic procedures such as cerclage and tendon repair. Its non-absorbable nature guarantees indefinite wound support, with the highest tensile strength of all suture materials available on the market, maintaining tension strength throughout the healing process and permanently.
How this suture works: why 316 steel makes the difference
The thread is an uncoated 316 surgical stainless steel monofilament, a high-purity alloy (chromium, nickel and molybdenum) that gives it exceptional corrosion resistance in contact with biological fluids and minimal tissue reaction. Being inert and non-absorbable, the suture gradually encapsulates in the tissue, maintaining its tensile strength indefinitely; hence it is the current standard in sternal fixation and the preferred option in orthopaedics when prolonged load retention is required. The ½ circle needle (HS48) with triangular reverse cutting point of 48 mm offers clean and controlled penetration in dense tissues such as the sternal bone and fasciae, minimising trauma.
Technical specifications
| Material | Surgical stainless steel 316, uncoated monofilament |
| Gauge | USP 6 (metric equivalent EP 8) |
| Needle type | ½ circle, triangular point, reverse cutting |
| Needle size | HS 48 mm |
| Configuration | 4 strands of 45 cm with needle |
| Finish | Ribbed metal, uncoated |
| Absorption | Non-absorbable, gradual encapsulation |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Manufacturer reference | P961HS4806.4 |
| SKU Cahnos | AMP961HS4806.4 |
Indicated for abdominal wound closure, orthopaedic surgeries, tendon repair and sternal closure, ensuring excellent tensile strength and gradual encapsulation.
Equivalences and cross-references
There is no official equivalence table validated by the manufacturer for this reference; the correspondences indicated below are functional comparisons verified against catalogues and official sources of the cited manufacturers, and must be confirmed with the technical department before use in tendering.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J) | Surgical Stainless Steel (Surgisteel) | M654G (USP 6, CCS needle 48 mm ½ circle, 4×45 cm) | Direct configuration equivalence | Same gauge USP 6 (EP 8), same needle size 48 mm ½ circle and same presentation 4×45 cm; the CCS needle is conventional cutting, geometry very close to the triangular reverse cutting; verify availability and registration. |
| B. Braun | Steelex Sternum Set | G0617814 (STE SET 6 (8) 4×45 cm HRS48) | Comparable at category level, not interchangeable 1:1 | Same gauge USP 6 (EP 8) and 4×45 cm, but the HRS48 needle has a round body with sternum point, a different geometry from the triangular reverse cutting. |
| Lorca Marín | Monofilament steel suture | No publicly verified code | Comparable by category | Spanish manufacturer of monofilament steel sutures for abdominal, tendon and sternal containment; code not verifiable in public sources, confirm with the manufacturer. |
Selection tips and variants of interest
For standard sternal closure after sternotomy, USP 6 gauge with 48 mm needle offers an excellent balance between needle passage and load retention in high-density tissues. In the same family Premisut Prime HS48 (½ circle triangular needle 48 mm, 4×45 cm) the gauges USP 2 (AMP961HS4802.4), USP 4 (AMP961HS4804.4), USP 5 (AMP961HS4805.4) and USP 7 (AMP961HS4807.4) are available, allowing strength to be adjusted according to tissue and surgeon preference; there is also the HS40 mm variant in USP 2 (AMP961HS4002.4). The 2=1=1=1 knotting technique is recommended and hold the needle between 1/3 and 1/2 of the distance from the connection to avoid deformation. Store below 30 °C, away from moisture and direct sunlight; do not re-sterilise or reuse.