Description
1. Commercial Introduction
The Silk Suture PREMISUT 3/8 Triangular DS90 USP 2 (manufacturer’s ref. 543DS9002, SKU AM543DS9002) is the reference in Cahnos’ standard range of non-absorbable silk sutures for procedures requiring a natural thread of long length and a long-body reverse cutting needle. This configuration combines a 100% natural braided silk thread, identifying black colour, USP 2 gauge and 90 cm of grooved strand, mounted on a ⅜ circle needle with a 90 mm reverse cutting triangular point (DS90 profile). It is a common choice in general surgery, skin surgery, ophthalmology, neurosurgery and oral surgery departments, as well as in purchasing centres and tenders that require a permanent thread with predictable clinical behaviour and full traceability. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets.
2. Technical Explanation
Silk is a natural protein fibre (Filum bombycis) transformed into a braided multifilament suture, coated with a mixture of wax and silicone. This coating reduces the capillary effect and bacterial drag, improves sliding through tissues and guarantees a secure and very firm knot, one of the most valued qualities of surgical silk. Being a non-absorbable material, it remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, with sufficient slack for the critical healing phase.
The 90 mm DS90 needle features a ⅜ circle curvature with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound, preserving the skin edge and preventing the cut from widening in the puncture bed, facilitating passage through firm, non-distensible tissues. Its great length makes it especially suitable for deep approaches, muscle planes and sutures of wide fields. The USP 2 gauge (metric EP 5) provides high resistance for tissues with medium-high tension and retention sutures, and the 90 cm of thread offer sufficient length for continuous sutures or multiple stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | Premisut (standard range) |
| Thread material | 100% natural silk (Filum bombycis), multifilament |
| Thread structure | Braided (multifilament), fluted surface |
| Coating | Wax and silicone |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 2 (metric EP 5); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.45 – 0.499 mm (USP range for non-absorbable suture) |
| Thread length | 90 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 3/8 circle (⅜ circular) |
| Tip type | Reverse cutting triangular |
| Needle size | DS 90 (90 mm) |
| Configuration | 1 needle per unit, grooved thread |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, skin closure under tension, ophthalmology, neurosurgery and oral surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); minimum order 30 boxes; batch traceability |
| Factory reference | 543DS9002 |
| Reference Cahnos (SKU) | AM543DS9002 |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2 | 5 | 0.45 – 0.499 mm |
3.3. Premisut family in silk – DS90 needle (⅜ circle, 90 mm, reverse cutting triangular point, black thread)
| Needle profile | USP size | Reference |
| DS90 | 1 | 543DS9001 / AM543DS9001 |
| DS90 | 2 | 543DS9002 / AM543DS9002 (this product) |
| DS90 Prime | 2 | P543DS9002 / AMP543DS9002 |
4. Equivalences and Cross-References
Reference 543DS9002 corresponds to the official nomenclature of the Premisut range (DS90 profile: ⅜ circle needle with 90 mm reverse cutting triangular point, USP 2 gauge, 90 cm grooved black thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Non-absorbable braided black silk is one of the most standardised natural suture families on the market (commercially type “Silkam”).
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Silkam® Black – coated braided natural silk, USP 2 (EP 5), 75 cm black thread, DS30 needle (⅜ circle, 30 mm, reverse cutting triangular point) | C0762504 (verified in official catalogue B. Braun Aesculap) | Comparable by category (not interchangeable 1:1) | They match in material (coated braided multifilament natural silk), USP 2 gauge (EP 5), black colour, ⅜ circle curvature and DS point family (reverse cutting triangular); they differ in thread length (75 cm vs 90 cm) and needle size (DS30 of 30 mm vs DS90 of 90 mm), so access to deep planes is not identical. |
The exact combination of USP 2 + black + 90 cm thread + 90 mm DS90 needle has not been found verified in public catalogues of other manufacturers or in regulatory databases (GUDID/EUDAMED); this geometry is only fully safely interchangeable within the Premisut system itself. Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour, coating and CE/MDR regulatory classification) before any substitution: Ethicon MERSILK / PERMA-HAND SILK (braided black silk), B. Braun SILKAM, Laboratorio Aragó SEDA negra section TB (3/8 circular triangular), Unilene SEDA NEGRA TRENZADA, Clarben Octosutur Seda and Trusilk silk presentations distributed by GIMA.
There is no equivalence table validated by the manufacturer for this configuration; check in the technical data sheet or IFU of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. Consult Cahnos’ technical department to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: USP 2 gauge (EP 5) offers maximum resistance for firm subcutaneous tissue, fasciae, aponeuroses, skin closures under tension and retention sutures or ligatures. The reverse cutting needle passes through dense tissues without tearing the puncture bed and, due to its length, the DS90 profile is especially indicated for deep approaches and wide fields. For finer planes, consider gauges 1, 3/0 or 2/0 from the same line.
Variants of the same DS90 needle in silk: the same 90 mm needle is offered in USP 1 (Ref. 543DS9001) and, in Prime quality, the same geometry and gauge (Ref. P543DS9002, SKU AMP543DS9002), allowing supplier unification across the entire range of non-absorbable long-needle sutures. If the needle is too long for the surgical field, the DS40–DS50 families (40–50 mm) cover intermediate approaches (e.g. DS40 in USP 2, Ref. 543DS4002, and DS50 in USP 2/0, Ref. 543DS5020).
Thread length: this reference is 90 cm (series 543); when the procedure requires less length, there are presentations of the same family in 75 cm thread (series 542) or 45 cm (series 541).
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 543DS9002 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.