We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

SILK Non-Absorbable Suture PREMISUT – 3/8 Circle Triangular Reverse Cutting Needle DS19 (19 mm), USP 1, Black Braided, 75 cm | Ref. 542DS1901 (Box of 12 units)

Original price was: 19,90 €.Current price is: 13,70 €.

Non-absorbable surgical suture of 100% natural braided silk from the PREMISUT range, coated with wax and silicone for smooth sliding, minimal capillarity and excellent knot security. Presentation of 1 black fluted 75 cm thread mounted on a ⅜ circle needle with triangular reverse cutting point of 19 mm (DS19 profile). USP 1 gauge (metric EP 4), with gradual encapsulation and wound support for more than three months. Sterile by ethylene oxide and single-use; indicated for approximation of soft tissues, ligatures, ophthalmology and skin surgery. Factory ref. 542DS1901 · SKU AM542DS1901 · Box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM542DS1901

Description

1. Commercial Introduction

The PREMISUT silk suture is the classic choice when looking for a non-absorbable thread of natural origin with exceptional feel, firm knot and predictable behaviour in soft tissue closure. This presentation in USP 1 calibre, with a ⅜ circle needle with a 19 mm reverse cutting triangular point (DS19 profile) and 75 cm black braided thread, is designed for the professional who needs a safe, highly visible material that is comfortable to work with in general, dermatological and ophthalmic surgery and procedures on firm tissues in a reduced field. Available in a box of 12 units in individual sterile sachets, with a very competitive price-quality ratio for B2B contracts, tenders and continuous replenishment in the operating theatre.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein fibre (fibroin, from the cocoon of Bombyx mori) presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating reduces the capillary effect and friction when passing through tissue, improves handling and favours knot seating (recommended knotting technique 2 = 1 = 1 = 1). Being a non-absorbable material, the thread does not degrade by hydrolysis: it gradually encapsulates and maintains tensile strength for more than three months, providing sustained support to the wound throughout the critical healing phase.

The 19 mm DS19 needle, with a grooved reverse cutting triangular body and point, concentrates the cutting edge on the outer face of the curvature, which facilitates penetration into firm tissues (skin, mucous membranes, aponeuroses) with minimal resistance, control in reduced surgical fields and better aesthetic results. The grooved black colour ensures optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Quality PREMISUT (standard quality)
Factory reference 542DS1901
SKU Cahnos AM542DS1901
Thread material 100% natural silk (fibroin from Bombyx mori), braided multifilament
Thread structure Braided, grooved surface (black)
Coating Wax and silicone
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / USP size USP 1 (metric EP 4)
Approximate thread diameter 0.40 – 0.449 mm (USP range for non-absorbable suture)
Thread length 75 cm (1 thread per unit)
Thread colour Grooved black (high visibility)
Needle shape ⅜ circle (3/8)
Tip type Reverse cutting triangular, triangular body and point, grooved
Needle size 19 mm (DS19 model)
Swaged 1 needle per suture
Knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology, skin surgery
Commercial presentation Box of 12 units (individual sterile sachets)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
1 (this product) 4 0.40 – 0.449 mm

3.3. PREMISUT DS19 family (⅜ circle needle, 19 mm, reverse cutting, black thread) in the Cahnos catalogue

Quality USP size Presentation Reference (SKU)
Standard 1 1 × 75 cm 542DS1901 – AM542DS1901 (this product)
Standard 0 1 × 75 cm 542DS1910 – AM542DS1910
Standard 2/0 1 × 75 cm 542DS1920 – AM542DS1920
Standard 3/0 1 × 75 cm 542DS1930 – AM542DS1930
Standard 4/0 1 × 75 cm 542DS1940 – AM542DS1940
Standard 5/0 1 × 75 cm 542DS1950 – AM542DS1950
Standard 6/0 1 × 75 cm 542DS1960 – AM542DS1960
Prime 1 2 × 75 cm (double thread) P542DS1901.2 – AMP542DS1901.2

4. Equivalences and Cross-References

Reference 542DS1901 corresponds to the official nomenclature of the PREMISUT range (DS19 profile: ⅜ circle needle with 19 mm reverse cutting triangular point, USP 1 calibre, 75 cm black braided thread) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.

Non-absorbable coated black braided silk is one of the most standardised natural suture families on the market. The following references share material, USP 1 calibre, black colour, thread length and 19 mm reverse cutting needle geometry in ⅜ circle, but as they come from other manufacturers they are not interchangeable 1:1 without prior validation. The codes have been checked against the manufacturer’s official catalogue and the GUDID/FDA regulatory database.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun Silkam® – non-absorbable waxed braided silk C0762384 (SILKAM BLACK 1 (4) 75CM DS19) Comparable by category (not interchangeable 1:1) Matching configuration in material (coated braided silk), USP 1 calibre (EP 4), black colour, 75 cm and DS19 needle of ⅜ circle reverse cutting 19 mm, 1 needle per thread. The official coating of Silkam is described as wax/paraffin versus wax and silicone for the Cahnos product; verify IFU before substituting. Verified in the official B. Braun catalogue and GUDID/FDA (04038653992287).
Ethicon (J&J MedTech) MERSILK® / PERMA-HAND™ Silk – black braided silk P1691H Comparable by category (not interchangeable 1:1) They match material (coated black braided silk), USP 1 calibre and 75 cm thread length with reverse cutting point; FSLX needle of 19 mm in ⅜ circle, equivalent in size and geometry to the DS19 profile. Confirm in the manufacturer’s official data sheet the type of coating and regulatory classification before any substitution. Verified in the official Ethicon catalogue and GUDID/FDA regulatory database (10705031102699).

There is no manufacturer-validated equivalence table that cross-references this configuration (DS19 needle of 19 mm, USP 1, black, 75 cm) with references from other houses; consult the technical department before using in a tender. Before any formal substitution, verify in the alternative manufacturer’s technical data sheet or IFU the exact calibre, needle curvature and size, point geometry, number and length of threads, colour, coating and regulatory classification (CE/MDR). Other homologous families of black braided silk on the market (Medtronic Sofsilk™, SMI, DemeTECH DemeSILK™, Assut Surgisilk™, Serag-Wiessner, Unilene, Laboratorio Aragó, Clarben Octosutur Seda, Lorca Marín) must be reviewed property by property before any substitution.

5. Selection tips and variants of interest

Select the calibre according to the anatomical area and expected tension: USP 1 calibre (metric 4) provides high resistance for deep planes, fascias, aponeuroses and ligatures of medium-calibre vessels; for finer or paediatric tissues you can go down to USP 2/0 (AM542DS1920), USP 3/0 (AM542DS1930), USP 4/0 (AM542DS1940) or USP 5/0 (AM542DS1950) within the same DS19 family, and if you need greater resistance you have USP 0 (AM542DS1910).

The DS19 19 mm needle in a ⅜ circle with reverse cutting is indicated for firm tissues with controlled penetration, good cosmetic result and reduced surgical fields (skin surgery, ophthalmology, oral surgery); if the tissue is very lax, consider the same family with a conical point for less trauma. If you prefer a precision finish, the Prime version of the same family is available in USP 1 gauge with double thread 2 × 75 cm (AMP542DS1901.2). For greater needle reach, move up to the DS24 (AM542DS2401) or DS37 (AM542DS3701) profiles in the same range.

As this is a sterile single-use product, check the integrity of the blister and the expiry date before each procedure, keep reference 542DS1901 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.

Additional information

Material

100% natural silk (fibroin from Bombyx mori), braided multifilament

Coating

Wax and silicone

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 1 (metric EP 4)

Thread diameter

0.40 – 0.449 mm

Thread length

75 cm (1 strand)

Thread colour

Fluted black

Tip type

Reverse cutting triangular, triangular body and point, grooved

Needle size

19 mm (DS19)

Swaged

1 needle per suture

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Presentation

Box of 12 units (individual sterile sachets)

Manufacturer reference

542DS1901

Knotting technique

2 = 1 = 1 = 1

Medida de aguja

DS 19

Usp

1

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “SILK Non-Absorbable Suture PREMISUT – 3/8 Circle Triangular Reverse Cutting Needle DS19 (19 mm), USP 1, Black Braided, 75 cm | Ref. 542DS1901 (Box of 12 units)”

Your email address will not be published. Required fields are marked *