We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

SEDA Suture PREMISUT 3/8 Reverse Cutting Triangular DS50 (50 mm) – USP 1 Black Braided · Thread 90 cm · Box of 12 units (Ref. 543DS5001)

Original price was: 19,90 €.Current price is: 12,20 €.

Non-absorbable suture of 100% natural braided silk (PREMISUT, Ref. 543DS5001 · SKU AM543DS5001) with a ⅜ circular needle with reverse cutting triangular point of 50 mm (DS50 profile), USP 1 gauge (metric EP 4) and black grooved thread of 90 cm. Coated with wax and silicone, it offers high tensile strength, a firm and secure knot and gradual encapsulation that maintains wound approximation for more than three months. Sterilised by ethylene oxide, single-use. Presentation: box of 12 units in individual sachets. Indicated for approximation of soft tissues, ligatures, ophthalmology and skin surgery.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM543DS5001

Description

1. Commercial Introduction

The Silk Suture PREMISUT 3/8 Triangular DS50 USP 1 (factory ref. 543DS5001, SKU AM543DS5001) is the reference in the standard range of non-absorbable silk sutures from Cahnos for procedures requiring a natural thread of surgical quality with a medium-long body reverse cutting needle. This configuration combines a 100% natural braided silk thread, identifying black colour, USP 1 gauge and 90 cm of grooved strand, mounted on a ⅜ circle needle with a 50 mm reverse cutting triangular point (DS50 profile). It is a common choice in general surgery, skin surgery, ophthalmology and oral surgery departments, as well as in purchasing centres and tenders that require a permanent thread with predictable clinical behaviour and full traceability. Sterile product, ready to use, presented in a box of 12 units in individual sachets.

2. Technical Explanation

Silk is a natural protein fibre (Filum bombycis) transformed into a braided multifilament suture, coated with a mixture of wax and silicone. This coating reduces the capillary effect and bacterial drag, improves sliding through tissues and guarantees a secure and very firm knot, one of the most valued qualities of surgical silk. Being a non-absorbable material, it remains in the tissue indefinitely, gradually encapsulating and maintaining a high tensile strength for more than three months, with sufficient slack for the critical healing phase.

The DS50 needle of 50 mm has a ⅜ circle curvature with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound, which preserves the skin edge and prevents the cut from widening in the puncture bed, facilitating passage through firm and non-distensible tissues. The USP 1 gauge (metric EP 4) provides high tensile strength for tissues with medium tension and retention sutures, while the 90 cm of thread offer sufficient length for continuous sutures or multiple stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Quality Premisut (standard range)
Thread material 100% natural silk (Filum bombycis), multifilament
Thread structure Braided (multifilament), fluted surface
Coating Wax and silicone
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / USP size USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges
Approximate thread diameter 0.40 – 0.449 mm (USP range for non-absorbable suture)
Thread length 90 cm (free end, without loop)
Thread colour Black identifier (high visibility in surgical field)
Needle shape 3/8 circle (⅜ circular)
Tip type Reverse cutting triangular
Needle size DS 50 (50 mm)
Configuration 1 needle per unit, grooved thread
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, skin closure, ophthalmology and oral surgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability
Factory reference 543DS5001
Reference Cahnos (SKU) AM543DS5001

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
1 4 0.40 – 0.449 mm

3.3. Premisut family in silk – DS50 needle (⅜ circle, 50 mm, reverse cutting triangular point, black thread)

Needle profile USP size Reference
DS50 2/0 543DS5020 / AM543DS5020
DS50 0 543DS5010 / AM543DS5010
DS50 1 543DS5001 / AM543DS5001 (this product)
DS50 Prime 1 P543DS5001 / AMP543DS5001
DS50 Prime (2 threads) 1 P543DS5001.2 / AMP543DS5001.2

4. Equivalences and Cross-References

Reference 543DS5001 corresponds to the official nomenclature of the Premisut range (DS50 profile: ⅜ circle needle with 50 mm reverse cutting triangular point, USP 1 gauge, black 90 cm grooved thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Non-absorbable black braided silk is one of the most standardised natural suture families on the market (commercially type «Silkam»).

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparison is functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Silkam® Black – coated braided natural silk, black suture, 3/8 circle needle with reverse cutting triangular tip C0762504 (verified in official catalogue B. Braun Aesculap) Comparable by category (not interchangeable 1:1) They match in material (natural braided and coated multifilament silk), black colour and DS point family (reverse cutting triangular, ⅜ circle curvature); they differ in gauge (USP 2 EP 5 vs USP 1 EP 4), needle size (DS30 of 30 mm vs DS50 of 50 mm) and thread length (75 cm vs 90 cm), so they are not interchangeable 1:1.

The exact combination USP 1 + black + 90 cm thread + DS50 needle of 50 mm has not been found verified in public catalogues of other houses or in regulatory databases (GUDID/EUDAMED); this geometry is only safely interchangeable within the Premisut system itself. Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour, coating and CE/MDR regulatory classification) before any substitution: Ethicon MERSILK / PERMA-HAND SILK (black braided silk), B. Braun SILKAM, Laboratorio Aragó SEDA negra section TB (3/8 circular triangular), Unilene SEDA NEGRA TRENZADA, Clarben Octosutur Seda and the Trusilk silk presentations distributed by GIMA.

There is no equivalence table validated by the manufacturer for this configuration; check in the technical data sheet or IFU of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence.

5. Selection tips and variants of interest

  • Tissue to suture: USP 1 gauge (EP 4) offers medium-high strength for subcutaneous tissue, fasciae, skin closures under tension, ligatures and retention sutures. The reverse cutting needle penetrates dense tissues without tearing the puncture bed.
  • Variants of the same DS50 needle in silk: the same 50 mm needle is offered in USP 0 (Ref. 543DS5010), USP 2/0 (Ref. 543DS5020) and, in Prime quality, the same geometry and gauge (Ref. P543DS5001, SKU AMP543DS5001), in addition to the double thread version 2×90 cm (Ref. P543DS5001.2). This allows unifying supplier across the entire range of non-absorbable medium needle sutures.
  • Thread length: this reference is 90 cm (series 543); when the procedure requires a shorter length, there are presentations of the same family in 75 cm thread (series 542) or 45 cm (series 541). For deeper access or wide fields, the same family offers longer needles (e.g. DS90 in USP 1, Ref. 543DS9001).
  • Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 543DS5001 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.

Additional information

Material

100% natural silk (Filum bombycis), multifilament

Coating

Wax and silicone

Metric gauge (EP)

4

Thread diameter

0.40 – 0.449 mm

Needle shape

3/8 circle (⅜ circular)

Tip type

Reverse cutting triangular

Needle size

DS50 (50 mm)

Configuration

1 needle per unit

Sterilisation

Ethylene oxide (EO)

Use

Single-use, sterile, non-resterilisable

Indications

Approximation of soft tissues, ligatures, ophthalmology, skin surgery

Presentation

Box of 12 units

Manufacturer reference

543DS5001

Medida de aguja

DS 50

Usp

1

Color

Black

Medida de hilo

90 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Estructura hilo

Braided multifilament

Absorcion

Non-absorbable