Description
1. Commercial Introduction
The Silk Suture PREMISUT Prime is the classic and reliable choice for closing soft tissues when a non-absorbable material with predictable behaviour, long clinical track record and outstanding knot security is required. This reference combines the handleability and firm feel of natural braided silk with a wax and silicone coating that facilitates thread glide and protects the tissue during suturing.
Mounted on a ⅜ circle needle with a 16 mm reverse cutting triangular point (DS16 series), in USP 3/0 gauge and 75 cm black thread, it is ideal for professionals in general surgery, skin and aesthetic surgery, dermatology, ophthalmology and veterinary practice. It is supplied in a box of 12 units in individual sterile sachets, ready for use in the operating theatre and with full batch traceability.
2. Technical explanation of the material and procedure
Surgical silk is a natural protein (fibroin from Bombyx mori) whose filaments are washed, degummed, braided and coated with a mixture of wax and silicone. This braided multifilament structure provides excellent tensile strength, flexibility and knot security far superior to that of monofilaments, while the coating reduces capillarity and bacterial wicking, minimising tissue trauma when passing through tissue.
Being non-absorbable, the thread remains in the body producing gradual encapsulation and maintains wound approximation for more than three months, comfortably covering the critical healing phase. The DS16 needle, 16 mm in ⅜ circle with reverse cutting triangular point (reverse cutting), concentrates the cutting edge on the outer face of the curvature, so it passes through firm tissues —skin and mucosa— with a clean cut without tearing the puncture site; its contained size makes it especially suitable for skin surgery, restricted-access areas and precision sutures in ophthalmology. The black colour ensures optimal contrast on the surgical field. The recommended knotting technique is 2 = 1 = 1 = 1. Ethylene oxide (EO) sterilisation ensures sterile delivery; it is a single-use product and does not allow re-sterilisation.
3. Technical Specifications
Data verified according to the manufacturer’s technical data sheet (PREMISUT Prime range).
| Parameter | Specification |
|---|---|
| SKU Cahnos | AMP542DS1630 |
| Factory reference | P542DS1630 |
| Brand / Range | PREMISUT Prime |
| Material | 100% natural braided silk (fibroin), coated with wax and silicone |
| Thread structure | Braided (multifilament), fluted surface |
| Gauge / USP size | USP 3/0 · Metric EP 2 |
| Approximate thread diameter | 0.20 – 0.25 mm (non-absorbable suture, USP Pharmacopoeia) |
| Thread colour | Black (high visibility) |
| Needle shape | ⅜ circle (3/8 curvature), body and point |
| Tip type | Reverse cutting triangular (reverse cutting), grooved |
| Needle size | 16 mm (DS16 model) |
| Swaged | 1 needle per suture |
| Thread length | 75 cm |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
Gauge equivalence (according to manufacturer’s technical data sheet):
| USP size | Metric measurement (EP) | Approximate diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.25 mm (non-absorbable suture, USP Pharmacopoeia) |
Reading of the factory reference: P = Prime line; 542 = 75 cm thread (541 = 45 cm); DS16 = ⅜ circle needle with 16 mm reverse cutting triangular point; 30 = USP 3/0 gauge. Cahnos markets the reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
The reference P542DS1630 corresponds to the official nomenclature of the PREMISUT Prime range (DS16 profile: ⅜ circle needle with 16 mm reverse cutting triangular point, USP 3/0 gauge, 75 cm black grooved thread, single needle configuration). Non-absorbable black braided silk is one of the most standardised natural suture families on the market (commercial types Silkam®, MERSILK® / PERMA-HAND™ or DemeSILK™). The references from other manufacturers detailed below have been checked against the official manufacturer catalogue or regulatory database (GUDID/FDA) and authorised distribution; as they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU before any substitution. This needle geometry (DS16, USP 3/0, 75 cm, single needle) is only fully safely interchangeable within the PREMISUT system itself.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | Silkam® black – non-absorbable waxed braided silk | C0764140 – SILKAM BLACK 3/0 (2) 75 CM DS16 | Comparable by category (not interchangeable 1:1) | They match in material (braided silk coated with wax/paraffin), USP 3/0 gauge (EP 2), black colour, 75 cm thread length and the same DS16 needle of 16 mm in ⅜ circle with reverse cutting triangular point. Code and attributes confirmed in the official B. Braun catalogue (DS16 profile, 3/8 needle reverse cutting of 16 mm). They differ only in brand, exact coating composition and sterilisation method (gamma radiation versus ethylene oxide); it is the closest technical match located. |
| Ethicon (Johnson & Johnson MedTech) | PERMA-HAND™ Silk / MERSILK® – non-absorbable black braided silk | 675H – 3/0, black, 75 cm, FSL needle of ⅜ circle with reverse cutting (30 mm) | Comparable by category (not interchangeable 1:1) | They match in material (waxed braided silk), USP 3/0 gauge, black colour and 75 cm length, with a reverse cutting point family in ⅜ circle. Code and attributes confirmed at the Ethicon product centre and authorised distribution. The needle size differs: FSL of 30 mm versus the 16 mm of this reference; greater reach, not recommended for precision sutures in restricted access. |
| Ethicon (Johnson & Johnson MedTech) | PERMA-HAND™ Silk – black braided non-absorbable silk | W2523T – 3/0, black, 75 cm, PSLX needle of ⅜ circle with reverse cutting | Comparable by category (not interchangeable 1:1) | They match in material, USP 3/0 gauge, black colour and 75 cm length, with a reverse cutting point family in ⅜ circle. Code consistently located in authorised distribution. The exact size of the PSLX needle must be verified against the Ethicon technical data sheet: the PSLX profile of the series is of greater length (≈ 36–40 mm depending on reference) versus the 16 mm of this reference. |
| DemeTECH | DemeSILK™ – braided multifilament silk, non-absorbable | SK263019F4P – 3/0, black, 75 cm, DFS-2 needle of ⅜ circle with reverse cutting (19 mm) | Comparable by category (not interchangeable 1:1) | They match in USP 3/0 gauge, black colour, 75 cm length and reverse cutting needle point family in ⅜ circle. Code and attributes confirmed at the official DemeTECH store and authorised distribution. The needle size differs (DFS-2 of 19 mm versus DS16 of 16 mm), outside the tolerance for direct exchange; greater reach in tissue. |
There is no manufacturer-validated equivalence table that cross-references this specific configuration (black braided silk, DS16 needle of 16 mm in ⅜ circle, USP 3/0 gauge and 75 cm strand, Prime quality) with references from other manufacturers; consult the technical department before use in tendering. Other homologous families of black braided silk with ⅜ circle needle and reverse cutting are: Medtronic (Sofsilk®), LOOK™ Silk (Corza Medical), Serag-Wiessner, Laboratorio Aragó (black silk), Assut Surgisilk™ and Unilene BLACK BRAIDED SILK. Before any formal substitution, check in the technical data sheet or IFU of the alternative manufacturer the exact gauge, thread length, needle curvature and size, point geometry, colour, coating and regulatory classification (CE/MDR). The brands cited belong to their respective manufacturers and are mentioned solely as equivalence reference.
5. Selection tips and variants of interest
Assess the gauge according to the anatomical area: USP 3/0 (metric 2) is the reference gauge for fine and moderately tense tissues —skin, subcutaneous tissue and mucous membranes— and for precision approximation in ophthalmology. For more delicate tissues, it is advisable to go down to 4/0, 5/0 or 6/0; for deep planes or greater mechanical demand, USP 2/0, 0 or 1 may be considered. The DS16 needle, 16 mm, in ⅜ circle with reverse cutting, is intended for skin sutures and firm planes in areas with limited access; if greater depth reach is required, consider the DS19, DS26 or DS60 series from the same catalogue.
Variants of interest within the Cahnos catalogue, same PREMISUT Prime black silk range:
- AM542DS1630 (ref. 542DS1630): same DS16 configuration, USP 3/0, black, 75 cm in standard quality (direct internal equivalent).
- AMP542DS1620: DS16 needle, 16 mm, USP 2/0 gauge, black thread 75 cm (moderate tension).
- AMP542DS1640: DS16 needle, 16 mm, USP 4/0 gauge, black thread 75 cm (fine and aesthetic surgery).
- AMP542DS1650 / AMP542DS1660: DS16 needle, 16 mm, USP 5/0 and 6/0 gauges (microsurgery and extreme precision).
- AMP542DS1930: same USP 3/0 configuration with DS19 needle, 19 mm (slightly more reach).
- AMP542DS6020 and AMP541DS1260: configurations with DS60 (2/0) and DS12 (6/0) needles for deep planes or extreme precision.
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews