Description
1. Product Presentation
We place at your disposal the non-absorbable braided silk suture PREMISUT, reference 542DS6010 (SKU AM542DS6010), a professional solution for B2B supply to operating theatres, purchasing centres, general and specialised surgery services, as well as ophthalmology and skin surgery units.
This presentation incorporates a ⅜ circle needle with a triangular reverse cutting body and point (triangular inverted / reverse cutting) of 60 mm (DS60 profile), mounted on a black braided thread of 75 cm in USP 0 gauge (metric EP 3.5). It is one of the longest-reaching configurations in the curved needle silk family, ideal for deep access planes, wide fields and firm tissues, with predictable behaviour, high tensile strength and special conditions for volume contracts and tenders. Sterile, single-use product, presented in a box of 12 units in individual sachets.
2. Technical explanation of the material and procedure
Silk is a non-absorbable suture of natural origin, formed by fibroin filaments (protein from the cocoon of Bombyx mori) braided over a twisted core. This braided multifilament structure provides excellent tensile strength and very high knot security (recommended knotting technique 2 = 1 = 1 = 1), classic characteristics of surgical silk, as well as gradual encapsulation that maintains mechanical wound support for more than three months.
The wax and silicone coating reduces thread capillarity and bacterial drag, favours sliding through tissue and minimises the sawing effect during passage and knotting. The ⅜ circle needle with a 60 mm triangular reverse cutting point (reverse cutting) penetrates firm tissues such as skin and mucous membranes making a clean, controlled cut, with the cutting edge oriented towards the outside of the curve so as not to enlarge the puncture bed, minimising trauma and improving the aesthetic result. The grooved black colour guarantees optimal contrast on the surgical field. The product is supplied sterile by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | 542DS6010 |
| SKU Cahnos | AM542DS6010 |
| Brand / Range | PREMISUT – standard quality |
| Thread material | 100 % natural silk (fibroin from Bombyx mori), braided multifilament over twisted core |
| Thread structure | Braided (multifilament), fluted surface |
| Coating | Wax and silicone |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 0 (metric EP 3.5) |
| Approximate thread diameter | 0.35 – 0.399 mm (USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Fluted black (high visibility on the surgical field) |
| Needle shape | ⅜ circle (3/8), body and point |
| Tip type | Reverse cutting triangular (inverted triangular / reverse cutting), grooved |
| Needle size | 60 mm (model DS60) |
| Swaged | 1 needle per suture |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
Reference 542DS6010 corresponds to the official nomenclature of the PREMISUT range (DS60 profile: ⅜ circle needle with 60 mm triangular reverse cutting point, USP 0 gauge, 75 cm grooved black thread, single needle configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Non-absorbable coated black braided silk is one of the most standardised permanent suture families on the market. Below are references from other houses cross-checked against the manufacturer’s official catalogue (B. Braun Aesculap catalogue); as they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Silkam® black – non-absorbable waxed braided silk | C0764892 – SILKAM BLACK 1 (4) 75 cm DS60 | Comparable by category (not interchangeable 1:1) | They match in material (waxed braided silk), black colour, thread length 75 cm, DS60 needle of 60 mm in ⅜ circle with reverse cutting point and single needle configuration. Difference: USP 1 gauge (EP 4) versus USP 0 of this reference; not interchangeable 1:1. Code and attributes confirmed in official B. Braun catalogue. |
| B. Braun (Aesculap) | Silkam® black – non-absorbable waxed braided silk | C0762679 – SILKAM BLACK 0 (3.5) 75 cm GS60 | Comparable by category (not interchangeable 1:1) | They match in material (waxed braided silk), USP 0 gauge (EP 3.5), black colour and thread length 75 cm. Difference: the needle is a straight GS60 with conventional cutting, not the curved ⅜ circle DS60 needle with reverse cutting; verify geometry before substituting. Code confirmed in official B. Braun catalogue. |
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (black braided silk, ⅜ circle DS60 needle of 60 mm with reverse cutting point, USP 0 gauge and 75 cm strand) with references from other houses; consult the technical department before using in tenders.
Other homologous families of non-absorbable black braided silk whose specific codes for this needle size are pending verification in an official source are: Ethicon MERSILK™ / PERMA-HAND™ Silk, Medtronic Sofsilk™, DemeTECH DemeSILK™, SMI Silk Braided, Assut Surgisilk™, Laboratorio Aragó (silk, 3/8 circular triangular), Unilene Seda Negra Trenzada and Clarben Octosutur Seda. In each case, verify in the technical data sheet or IFU of the alternative manufacturer the exact gauge, needle curvature and size, point geometry, thread length, colour, coating and regulatory classification (CE/MDR) before any direct substitution.
5. Selection tips and variants of interest
Select the gauge according to the anatomical area and expected tension: USP 0 gauge (metric EP 3.5) offers an ideal balance between flexibility and strength for skin with moderate tension, subcutaneous tissue, fasciae, ligation of medium-calibre vessels and oral cavity closures; the reverse cutting point penetrates dense tissues without tearing the puncture bed and improves the aesthetic result. The 60 mm DS60 needle provides great reach for deep planes and wide fields; for smaller fields, the same family is available in DS24, DS26, DS30, DS37, DS40 and DS45 profiles within the PREMISUT catalogue.
Variants of interest within the Cahnos catalogue:
| Reference (SKU) | Description |
| AMP542DS6010 | Silk PREMISUT Prime DS60, USP 0, black, 75 cm (premium quality, same configuration) |
| AM542DS6001 | DS60 needle, USP 1, black, 75 cm (greater thickness and mechanical support) |
| AM542DS6020 | DS60 needle, USP 2/0, black, 75 cm (finer and more versatile gauge) |
| AM542DS4010 | DS40 needle, USP 0, black, 75 cm (shorter needle for smaller fields) |
| AM542DS3010 | DS30 needle, USP 0, black, 75 cm (intermediate reach in skin surgery) |
| AMP642DS6010 | Prime monofilament nylon, DS60, USP 0, black, 75 cm (non-absorbable synthetic alternative) |
As this is a sterile single-use product, check the integrity of the blister and the expiry date before each procedure, keep reference 542DS6010 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.