Silk Suture PREMISUT Non-Absorbable · ½ Circle Needle Cylindrical Body Trocar Point HRT18 (18 mm) · USP 3/0 · Black Braided Thread 75 cm · Box of 12 units (Ref. 542HRT1830)

Original price was: 24,90 €.Current price is: 14,50 €.

Silk Suture PREMISUT non-absorbable of 100% natural silk, braided and coated with wax and silicone, mounted on a ½ circle needle with cylindrical body and trocar point (tapercut), 18 mm (HRT18 profile). USP gauge 3/0 (metric EP 2), black fluted thread, 75 cm. Non-absorbable: gradual encapsulation that maintains wound support for more than three months. Sterilised by ethylene oxide, single-use. Indicated for approximation of soft tissues, ligatures, ophthalmology and skin surgery. Box of 12 units in individual sterile sachets; minimum order of 30 boxes. Factory ref. 542HRT1830 · SKU AM542HRT1830.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM542HRT1830

Description

1. Commercial Introduction

The SEDA Suture PREMISUT HRT18 (factory ref. 542HRT1830 · SKU AM542HRT1830) is the reference in the standard range of non-absorbable braided silk from Cahnos for the professional who demands exceptional handling, reliable knotting and predictable clinical performance in soft tissue closure. This presentation mounts a ½ circle needle with cylindrical body and trocar point (HRT18 profile) of 18 mm together with 75 cm of black fluted thread, coated with wax and silicone to reduce friction and facilitate passage through tissue.

Designed for the operating theatre, ophthalmology clinic, dermatological surgery and minor surgery, it is presented in a box of 12 individual sterile sachets, ready to use and with full batch traceability. It is the continuous replenishment solution for surgical departments, purchasing centres and B2B contracts, with a minimum order of 30 boxes.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating minimises the capillarity of the multifilament, reduces drag when passing through tissue and improves knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HRT18 18 mm needle features a ½ circle curvature with cylindrical body and trocar point (tapercut): a cutting point that merges into a round body, allowing firm, poorly distensible tissues to be traversed without enlarging the puncture bed, minimising trauma and improving the aesthetic result. The black fluted colour guarantees optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Factory reference 542HRT1830 (PREMISUT range, Normal quality)
SKU Cahnos AM542HRT1830
Thread material 100% natural silk (fibroin from Bombyx mori), braided multifilament
Thread structure Braided (multifilament), fluted surface
Coating Wax and silicone (anti-capillarity, low drag)
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 3/0 (metric EP 2)
Approximate thread diameter 0.20 – 0.249 mm (USP, non-absorbable suture)
Thread length 75 cm (1 thread per unit)
Thread colour Fluted black (high visibility on the surgical field)
Needle shape ½ circle (1/2), cylindrical body
Tip type Trocar point (tapercut)
Needle size 18 mm (HRT18 profile)
Swaged 1 needle per suture
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (individual sterile sachets); minimum order of 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
4/0 1.5 0.15 – 0.199 mm
3/0 (this product) 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm

3.3. PREMISUT HRT18 family in silk (½ circle needle, 18 mm, trocar point, cylindrical body, black thread)

USP size Quality Thread Reference (SKU)
3/0 Normal 1 × 75 cm (black) 542HRT1830 / AM542HRT1830 (this product)
3/0 Prime 1 × 75 cm (black) P542HRT1830 / AMP542HRT1830
3/0 Normal 1 × 45 cm (black) 541HRT1830 / AM541HRT1830
3/0 Prime 1 × 45 cm (black) P541HRT1830 / AMP541HRT1830
4/0 Normal 1 × 75 cm (black) 542HRT1840 / AM542HRT1840
4/0 Prime 1 × 75 cm (black) P542HRT1840 / AMP542HRT1840

4. Equivalences and Cross-References

Reference 542HRT1830 corresponds to the official nomenclature of the PREMISUT range (54 = SEDA family; 2 = 75 cm thread; HRT = ½ circle needle with cylindrical body and trocar point; 18 = 18 mm; 30 = USP 3/0) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. The equivalent Prime-quality version of this same configuration is reference P542HRT1830 (SKU AMP542HRT1830), identical in material, needle, gauge, colour and length (exact reference equivalence within the same manufacturer).

Non-absorbable coated black braided silk is one of the most standardised natural suture families on the market. After cross-referencing against official catalogues and regulatory databases, no product from another brand has been found that matches 1:1 in all required fields —material (coated braided silk), USP 3/0 gauge, 75 cm black thread, ½ circle curvature, trocar/tapercut point and 18 mm needle— within the established measurement tolerance (±1 mm for needles ≥ 10 mm). There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. The closest homologous market references are listed below, verified source by source, for the professional to assess their clinical suitability:

  • Ethicon / Johnson & Johnson MedTech – PERMA-HAND™ Silk (K963G): black braided natural silk, USP 3/0, 75 cm, V-7 needle of 26 mm in ½ circle with tapercut point. Material, gauge, colour, length, curvature and trocar point family match, but the needle is 26 mm (outside the ±1 mm tolerance compared to the 18 mm of the HRT18). Verified in the official Ethicon catalogue and authorised distribution.
  • B. Braun – SILKAM® Black (C0760412): braided and impregnated natural multifilament silk (wax/paraffin coating), USP 3/0 (EP 2), 75 cm, HR26 needle of 26 mm in ½ circle. Material, gauge, colour, length and curvature match, but the point differs (the HR26 is conical, not trocar/tapercut) and the needle size. Verified in the official B. Braun catalogue.

Other homologous families present on the European market — Ethicon MERSILK™, Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Assusilk®, SMI A.G., LuxSutures® LuxSilk, Lorca Marín Seda Trenzada and Serag-Wiessner — must always be checked reference by reference: USP/metric gauge, length and number of threads, geometry and exact needle size, colour, coating and CE/MDR regulatory classification before proceeding with any substitution. Consult the technical department of Cahnos before use in tendering.

5. Selection tips and variants of interest

Gauge according to area and tension: USP 3/0 (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and soft tissues with moderate tension, as well as for ophthalmology and precision surgery. For more delicate planes (eyelids, microsurgery) consider gauge 4/0 with the same HRT18 needle (AM542HRT1840 in Normal quality or AMP542HRT1840 in Prime).

Needle geometry: the 18 mm HRT18 in ½ circle with cylindrical body and trocar point is indicated for firm tissues with controlled penetration and good cosmetic results. If you work in more superficial fields and seek greater rotational control, consider the same point in ⅜ circle (AM542DRT1830 / P542DRT1830, DRT18 in 3/0). For greater needle reach in the same 3/0 gauge, move up to the HRT26 profile (AM542HRT2630).

Thread length: this reference is 75 cm (series 542); when the procedure requires a shorter run, presentations of 45 cm (series 541) are available, such as the 541HRT1830 (Normal) or the P541HRT1830 (Prime).

Sterility verification: product sterilised by ethylene oxide and for single-use; check the integrity of the blister and the expiry date before each procedure, keep reference 542HRT1830 together with the lot number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team at Cahnos.

Additional information

Material

100% natural silk (fibroin from Bombyx mori), braided multifilament

Structure

Braided, fluted surface

Coating

Wax and silicone (anti-capillarity, low drag)

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

3/0 (metric EP 2)

Thread diameter

0.20 – 0.249 mm (USP)

Thread length

75 cm (1 thread per unit)

Thread colour

Fluted black

Needle shape

½ circle (1/2), cylindrical body

Needle size

18 mm (HRT18 profile)

Swaged

1 needle per suture

Knotting technique

2 = 1 = 1 = 1

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Presentation

Box of 12 units; minimum order of 30 boxes

Manufacturer reference

542HRT1830

Regulatory standard

USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HRT 18

Usp

3/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Silk Suture PREMISUT Non-Absorbable · ½ Circle Needle Cylindrical Body Trocar Point HRT18 (18 mm) · USP 3/0 · Black Braided Thread 75 cm · Box of 12 units (Ref. 542HRT1830)”

Your email address will not be published. Required fields are marked *