We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-Absorbable SILK Suture PREMISUT Prime · Needle ½ Circle Cylindrical Body Trocar Point HRT26 (26 mm) · USP 3/0 (Metric EP 2) · Black Braided Thread 75 cm · Box 12 units (Ref. P542HRT2630)

Original price was: 24,90 €.Current price is: 18,90 €.

Non-absorbable suture of 100 % natural braided silk from the PREMISUT Prime range (Ref. P542HRT2630 · SKU AMP542HRT2630), with a wax and silicone coating that reduces capillarity and facilitates sliding. Gauge USP 3/0 (metric EP 2), black grooved thread 75 cm mounted on a ½ circle needle with cylindrical body and 26 mm trocar point (HRT26 profile): controlled penetration in firm tissues with minimal trauma. Non-absorbable, with gradual encapsulation and wound support greater than three months; sterilised by ethylene oxide, single-use and not re-sterilisable. Indicated for approximation of soft tissues, ligatures, ophthalmology and skin surgery. Box of 12 units in individual sterile envelopes, minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542HRT2630

Description

1. Commercial Introduction

The Silk Suture PREMISUT Prime HRT26 (factory ref. P542HRT2630 · SKU AMP542HRT2630) is the reference of the Prime range of non-absorbable braided silk from Cahnos for the professional who demands exceptional handling, reliable knotting and predictable clinical behaviour in the closure of soft tissues. This presentation features a ½ circle needle with cylindrical body and trocar point (HRT26 profile) of 26 mm together with 75 cm of black fluted thread, coated with wax and silicone to reduce friction and facilitate passage through tissue.

Designed for the operating theatre, ophthalmology clinic, dermatological surgery and minor surgery, it is presented in a box of 12 individual sterile envelopes, ready to use and with full batch traceability. It is the continuous replenishment solution for surgical services, purchasing centres and B2B contracts, with a minimum order of 30 boxes.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating minimises the capillarity of the multifilament, reduces drag when passing through tissue and improves knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HRT26 needle of 26 mm features a ½ circle curvature with cylindrical body and trocar point (tapercut): a cutting point that merges into a round body, allowing firm tissues to be traversed without enlarging the puncture bed, minimising trauma and improving the aesthetic result. The black fluted colour guarantees optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Factory reference P542HRT2630 (PREMISUT Prime range)
SKU Cahnos AMP542HRT2630
Brand / Range PREMISUT (Prime quality)
Thread material 100% natural silk (fibroin from Bombyx mori), braided multifilament
Thread structure Braided (multifilament), fluted surface
Coating Wax and silicone (anti-capillarity, low drag)
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 3/0 (metric EP 2)
Approximate thread diameter 0.20 – 0.249 mm (USP, non-absorbable suture)
Thread length 75 cm (1 thread per unit)
Thread colour Fluted black (high visibility on the surgical field)
Needle shape ½ circle (1/2), cylindrical body
Tip type Trocar point (tapercut)
Needle size 26 mm (HRT26 profile)
Swaged 1 needle per suture
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (individual sterile sachets); minimum order of 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
4/0 1.5 0.15 – 0.199 mm
3/0 (this product) 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm

3.3. PREMISUT HRT26 family in silk (½ circle needle, 26 mm, trocar point, cylindrical body, black thread)

USP size Thread Reference (SKU)
3/0 (Prime) 1 × 75 cm (black) P542HRT2630 / AMP542HRT2630 (this product)
2/0 (Prime) 1 × 75 cm (black) P542HRT2620 / AMP542HRT2620
3/0 (Normal) 1 × 75 cm (black) 542HRT2630 / AM542HRT2630
2/0 (Normal) 1 × 75 cm (black) 542HRT2620 / AM542HRT2620

4. Equivalences and Cross-References

The reference P542HRT2630 corresponds to the official nomenclature of the PREMISUT range (P = Prime quality; 542 = 75 cm thread; HRT = ½ circle needle with cylindrical body and trocar point; 26 = 26 mm; 30 = USP 3/0) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. The equivalent version in Normal quality of this same configuration is reference 542HRT2630 (SKU AM542HRT2630), identical in material, needle, gauge, colour and length.

Non-absorbable coated black braided silk is one of the most standardised natural suture families on the market. The matches detailed below share material, gauge, colour, thread length, ½ circle curvature and trocar point family, and have been checked against the manufacturer’s official catalogue or authorised distribution; as they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon / Johnson & Johnson MedTech PERMA-HAND™ Silk Suture – natural braided silk, TAPERCUT, V-7 needle of 26 mm ½ circle, black, 75 cm, USP 3/0 K963G (verified on Ethicon product and authorised distributor data sheet; box of 12 units) Comparable by category (not interchangeable 1:1) They match in material (natural braided silk), USP 3/0 gauge (metric EP 2), black colour, 75 cm length, ½ circle curvature and V-7 trocar point of 26 mm. They differ in the exact coating (wax and silicone versus wax), the sterilisation system and the presentation format. Verify IFU and CE/MDR marking before substituting.
B. Braun (Aesculap) Silkam® Black – natural multifilament braided and impregnated silk (wax/paraffin coating), 3/0 (EP 2), 75 cm, HR26 needle C0760412 (verified in official B. Braun catalogue) Comparable by category (not interchangeable 1:1) They match in material (coated braided silk), USP 3/0 gauge (metric EP 2), black colour, 75 cm length and needle size of 26 mm in ½ circle. They differ in the point: the HR26 is a conical point (taper point), not trocar/tapercut, so it is not interchangeable 1:1 in needle geometry. Verify IFU and CE/MDR before substituting.

There is no equivalence table validated by the manufacturer (PREMISUT) for this specific configuration (black braided silk, HRT26 needle of 26 mm in ½ circle, trocar point, USP 3/0 gauge and 75 cm strand); the indicated cross-references are offered at the level of technical data sheet comparison and must be confirmed with the technical department before use in tendering. Other homologous families of non-absorbable black braided silk present on the European market — Ethicon MERSILK™, Medtronic Sofsilk™, DemeTECH DemeSILK™, SMI A.G., Assut Assusilk®, LuxSutures® LuxSilk, Lorca Marín Seda Trenzada and Serag-Wiessner — must always be checked reference by reference: USP/metric gauge, length and number of threads, geometry and exact needle size, colour, coating and CE/MDR regulatory classification before proceeding to any substitution. Consult with the technical department of Cahnos before use in tendering.

5. Selection tips and variants of interest

Gauge according to area and tension: USP 3/0 (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and soft tissues with moderate tension, as well as for ophthalmology and precision surgery. For more delicate planes, consider smaller gauges from the same family; for greater mechanical demand, USP 2/0 is available with the same HRT26 Prime needle (AMP542HRT2620) or USP 0 in Normal quality (AM542HRT2610).

Needle geometry: the HRT26, 26 mm, ½ circle, with cylindrical body and trocar point is indicated for firm tissues with controlled penetration and good cosmetic results. If you work on very lax tissues and seek less trauma, consider the same range with a conical point in ½ circle (e.g. AMP542HR2630, HR26 Prime in 3/0) or the reverse cutting triangular point variant (AMP542HS2630, HS26 in 3/0). For a shorter needle reach in the same 3/0 gauge, the HRT18 profile is available (AMP542HRT1830); for deeper fields, move up to the HRT30 (AM542HRT3030).

Thread length: this reference is 75 cm (series 542); when the procedure requires a shorter run, presentations of 45 cm (series 541) are available, such as the P541HRT1830 and P541HRT2630 in Prime quality.

Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P542HRT2630 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

P542HRT2630 (PREMISUT Prime range)

Material

100% natural silk (fibroin from Bombyx mori), braided multifilament

Thread structure

Braided (multifilament), fluted surface

Coating

Wax and silicone

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 3/0 (metric EP 2)

Thread diameter

0.20 – 0.249 mm (USP Pharmacopeia, non-absorbable)

Thread length

75 cm (1 thread per unit)

Thread colour

Fluted black

Needle shape

½ circle (1/2 circular), cylindrical body

Needle size

26 mm (HRT26 profile)

Swaged

1 needle per suture

Knotting technique

2 = 1 = 1 = 1

Quality

Prime (PREMISUT Prime)

Sterilisation

Ethylene oxide (EO); single-use, not re-sterilisable

Presentation

Box of 12 units; minimum order of 30 boxes

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HRT 26

Usp

3/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-Absorbable SILK Suture PREMISUT Prime · Needle ½ Circle Cylindrical Body Trocar Point HRT26 (26 mm) · USP 3/0 (Metric EP 2) · Black Braided Thread 75 cm · Box 12 units (Ref. P542HRT2630)”

Your email address will not be published. Required fields are marked *