We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-Absorbable SILK Suture PREMISUT · ½ Circle Needle Cylindrical Body Trocar Point HRT18 (18 mm) · USP 3/0 (Metric EP 2) · Black Braided Thread 45 cm · Box of 12 units (Ref. 541HRT1830 / SKU AM541HRT1830)

Original price was: 24,90 €.Current price is: 14,50 €.

Non-absorbable suture of 100% natural braided silk (PREMISUT range) with wax and silicone coating that reduces capillarity, facilitates sliding and ensures a firm, secure knot. Mounted on a ½ circle needle with cylindrical body and trocar point (tapercut) of 18 mm, HRT18 profile: controlled penetration into firm tissues with minimal trauma. USP gauge 3/0 (metric EP 2), black fluted thread of 45 cm, non-absorbable, with gradual encapsulation that maintains tensile strength for more than three months. Sterilised by ethylene oxide, single-use. Indicated for soft tissue approximation, ligatures, ophthalmology and skin surgery. Box of 12 units in individual sterile sachets, minimum order of 30 boxes. Factory ref. 541HRT1830 · SKU AM541HRT1830.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM541HRT1830

Description

1. Commercial Introduction

The SEDA PREMISUT HRT18 Suture (Factory ref. 541HRT1830 · SKU AM541HRT1830) is the standard-grade reference in non-absorbable braided silk from Cahnos for the professional who demands exceptional handling, reliable knot security and predictable clinical performance in soft-tissue closure. This presentation mounts a ½-circle needle with a cylindrical body and trocar point (HRT18 profile) of 18 mm together with 45 cm of black fluted thread, coated with wax and silicone to reduce friction and ease passage through tissue.

Designed for the operating theatre, ophthalmology clinic, dermatological surgery and minor surgery, it is supplied in a box of 12 individual sterile envelopes, ready to use and with full batch traceability. It is the continuous replacement solution for surgical services, purchasing centres and B2B contracts, with a minimum order of 30 boxes.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— presented in a braided multifilament construction and coated with a wax and silicone mixture. This coating minimises the capillarity of the multifilament, reduces drag when passing through tissue and improves knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HRT18 needle of 18 mm features a ½-circle curvature with a cylindrical body and trocar point (tapercut): a cutting point that merges into a round body, allowing it to pass through firm, non-distensible tissues without enlarging the puncture bed, minimising trauma and improving the cosmetic outcome. The black fluted colour ensures optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Factory reference 541HRT1830 (PREMISUT range, Normal quality, 1 thread per unit)
SKU Cahnos AM541HRT1830
Thread material 100% natural silk (fibroin from Bombyx mori), braided multifilament
Thread structure Braided (multifilament), fluted surface
Coating Wax and silicone (anti-capillarity, low drag)
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 3/0 (metric EP 2)
Approximate thread diameter 0.20 – 0.249 mm (USP, non-absorbable suture)
Thread length 45 cm (1 strand per unit)
Thread colour Fluted black (high visibility on the surgical field)
Needle shape ½ circle (1/2), cylindrical body
Tip type Trocar point (tapercut)
Needle size 18 mm (HRT18 profile)
Swaged 1 needle per suture
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (individual sterile sachets); minimum order of 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
4/0 1.5 0.15 – 0.199 mm
3/0 (this product) 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm

3.3. PREMISUT HRT18 family in silk (½ circle needle, 18 mm, trocar point, cylindrical body, black thread)

USP size Quality Thread Reference (SKU)
3/0 Normal 1 × 45 cm (black) 541HRT1830 / AM541HRT1830 (this product)
3/0 Prime 1 × 45 cm (black) P541HRT1830 / AMP541HRT1830
3/0 Normal 1 × 75 cm (black) 542HRT1830 / AM542HRT1830
3/0 Prime 1 × 75 cm (black) P542HRT1830 / AMP542HRT1830
4/0 Normal 1 × 75 cm (black) 542HRT1840 / AM542HRT1840
4/0 Prime 1 × 75 cm (black) P542HRT1840 / AMP542HRT1840

4. Equivalences and Cross-References

Reference 541HRT1830 corresponds to the official nomenclature of the PREMISUT range (54 = SEDA family; 1 = 45 cm thread; HRT = ½-circle needle with cylindrical body and trocar point; 18 = 18 mm; 30 = USP 3/0) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. The equivalent Prime-quality version of this same configuration is reference P541HRT1830 (SKU AMP541HRT1830), identical in material, needle, gauge, colour and length (exact reference equivalence within the same manufacturer).

Non-absorbable coated braided black silk is one of the most standardised natural suture families on the market. The matches detailed below share material, gauge, colour and point family, and have been cross-checked against the official manufacturer catalogue or authorised distribution; as they are from another brand they do not constitute exact reference equivalence (reserved to the same manufacturer) and must be validated against the IFU and CE/MDR classification before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon / Johnson & Johnson MedTech PERMA-HAND™ Silk Suture – natural braided black silk, USP 3/0, V-7 tapercut needle K963G (V-7 of 26 mm in ½ circle; verified on Ethicon product and authorised distribution) Comparable by category (not interchangeable 1:1) They match material (coated braided natural silk), gauge USP 3/0 (metric EP 2), black colour, ½-circle curvature and trocar point family. They differ in needle size (26 mm vs 18 mm, outside tolerance ±1 mm) and, depending on presentation, thread length (75 cm vs 45 cm). Verify IFU and CE/MDR before substituting.
B. Braun (Aesculap) SILKAM® Black – braided multifilament natural silk impregnated (wax/paraffin coating), USP 3/0 (EP 2), 75 cm, DRT18 needle trocar point (tapercut) 18 mm G0763218 (verified in official B. Braun catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match material (coated braided silk), gauge USP 3/0 (metric EP 2), black colour, needle size (18 mm) and trocar/tapercut point family. They differ in needle curvature (⅜-circle vs ½-circle) and thread length (75 cm vs 45 cm). Not interchangeable 1:1 in needle geometry or length.
B. Braun (Aesculap) SILKAM® Black – natural braided multifilament impregnated silk, USP 3/0 (EP 2), 75 cm, HR26 needle C0760412 (verified in official B. Braun catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match material (coated braided silk), gauge USP 3/0 (metric EP 2) and black colour. They differ in point (the HR26 is conical/taper point, not trocar/tapercut), needle size (26 mm vs 18 mm) and thread length (75 cm vs 45 cm). Verify IFU and CE/MDR before substituting.

There is no equivalence table validated by the manufacturer (PREMISUT) for this specific configuration (black braided silk, HRT18 needle of 18 mm in ½-circle, trocar point, gauge USP 3/0 and 45 cm strand); the cross-references indicated are offered at a technical data sheet comparison level and must be confirmed with the technical department before use in tendering. Other homologous families of non-absorbable black braided silk present on the European market — Ethicon MERSILK™, Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Assusilk®, SMI A.G., LuxSutures® LuxSilk, Lorca Marín Seda Trenzada and Serag-Wiessner — must always be checked reference by reference: USP/metric gauge, length and number of strands, needle geometry and exact size, colour, coating and CE/MDR regulatory classification before proceeding with any substitution. Consult the technical department of Cahnos before using in tendering.

5. Selection tips and variants of interest

Gauge by site and tension: USP 3/0 (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and soft tissues with moderate tension, as well as for ophthalmology and precision surgery. For more delicate planes (eyelids, microsurgery) consider gauge 4/0 with the same HRT18 needle (AM542HRT1840 in Normal quality or AMP542HRT1840 in Prime).

Needle geometry: the HRT18 of 18 mm in ½-circle with cylindrical body and trocar point is indicated for firm tissues with controlled penetration and good cosmetic outcome. If you work in more superficial fields and seek greater rotation control, consider the same point in ⅜-circle (basis DRT18) or step up to the HRT26 profile for greater needle reach in the same gauge 3/0 (AM542HRT2630).

Thread length: this reference is 45 cm (series 541), recommended for shorter procedures and stock anticoagulation in minor surgery; when the procedure requires a longer thread, the 75 cm series 542 is available (AM542HRT1830 in Normal quality or AMP542HRT1830 in Prime).

Sterility verification: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep reference 541HRT1830 together with the batch number for traceability in the operating theatre and store in a cool, dry place below 30 °C and protected from direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

541HRT1830

Brand / Range

PREMISUT (Normal quality)

Material

100% natural silk (fibroin from Bombyx mori), braided multifilament

Thread structure

Braided, fluted surface

Coating

Wax and silicone (anti-capillarity, low drag)

Absorption type

Non-absorbable; gradual encapsulation, wound support for more than 3 months

Gauge

USP 3/0 (metric EP 2)

Thread diameter

0.20 – 0.249 mm (USP)

Thread length

45 cm (1 strand per unit)

Colour

Fluted black

Needle shape

½ circle (1/2), cylindrical body

Needle size

18 mm (HRT18 profile)

Swaged

1 needle per suture

Knotting technique

2 = 1 = 1 = 1

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

30 boxes

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HRT 18

Usp

3/0

Color

Black

Medida de hilo

45 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Non-Absorbable SILK Suture PREMISUT · ½ Circle Needle Cylindrical Body Trocar Point HRT18 (18 mm) · USP 3/0 (Metric EP 2) · Black Braided Thread 45 cm · Box of 12 units (Ref. 541HRT1830 / SKU AM541HRT1830)”

Your email address will not be published. Required fields are marked *