Description
1. Commercial Introduction
We offer you the braided silk suture from the PREMISUT Prime range, factory reference P542HR2630.2 (SKU Cahnos AMP542HR2630.2), a professional solution for B2B supply to operating theatres, general and specialist surgery departments, ophthalmology units, skin surgery and hospital purchasing centres.
This double-thread presentation incorporates 2 black strands of 75 cm in USP 3/0 gauge, mounted on two ½ circle needles with cylindrical body and fluted taper point Taperpoint of 26 mm (HR26 Prime profile). It is the classic configuration for approximating soft tissues and ligatures with moderate tension, with the handling and knot security characteristic of surgical silk. It is supplied in a box of 12 sterile units, ready for immediate use.
2. Technical explanation
Surgical silk is a multifilament material of natural origin (fibroin protein from the cocoon of Bombyx mori), braided over a twisted core and coated with a thin layer of wax and silicone. This coating reduces the capillarity and wicking effect of the multifilament, facilitates the sliding of the strand through tissue with less friction, and improves knot seating with the recommended knotting technique 2 = 1 = 1 = 1, resulting in less tissue trauma and excellent handling.
Being non-absorbable, the strand does not degrade by hydrolysis or enzymes: a gradual encapsulation of the material occurs that maintains tensile strength and approximation integrity for more than three months, comfortably covering the critical healing phase. The HR26 needle of 26 mm, with ½ circle curvature, cylindrical body and fluted taper point Taperpoint, separates tissue fibres instead of cutting them, minimising trauma to soft and delicate tissues such as skin and ocular structures. The fluted black colour ensures optimal contrast on the surgical field. Each strand is sterilised by ethylene oxide (EO); single-use product and not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | P542HR2630.2 (suffix .2 = double-thread presentation) |
| Reference Cahnos (SKU) | AMP542HR2630.2 |
| Brand / quality | PREMISUT Prime (premium range, grooved needle) |
| Thread material | 100% natural silk (fibroin from Bombyx mori), multifilament braided over twisted core |
| Thread structure | Braided (multifilament), fluted surface |
| Coating | Wax and silicone (anti-capillarity, low tissue drag) |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 3/0 (metric EP 2); conforming to USP and European Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm (non-absorbable suture, USP Pharmacopoeia) |
| Configuration | 2 strands (double needle) of 75 cm each (2×75 cm; 150 cm per packet) |
| Thread colour | Fluted black (high visibility on the surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical fluted (Taperpoint), non-cutting |
| Needle size | 26 mm (HR26 Prime profile) |
| Swaged | 2 strands with needle per unit (one needle per strand) |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Compliant with USP/EP Pharmacopoeia for sterile non-absorbable sutures; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its limits.
3.3. PREMISUT Prime family with HR26 needle in silk (Cahnos catalogue)
| USP size | Presentation | Reference (SKU) |
| 4/0 | 1 × 75 cm (black) | AMP542HR2640 |
| 3/0 | 1 × 75 cm (black) | AMP542HR2630 |
| 3/0 | 2 × 75 cm (black) · this product | AMP542HR2630.2 |
| 2/0 | 2 × 75 cm (black) | AMP542HR2620.2 |
| 0 | 2 × 75 cm (black) | AMP542HR2610.2 |
| 1 | 2 × 75 cm (black) | AMP542RHR2601.2 |
4. Equivalences and Cross-References
The reference P542HR2630.2 corresponds to the official nomenclature of the PREMISUT Prime range (P = Prime quality; 542 = black thread 75 cm; HR = ½ circle needle with cylindrical body and taper point Taperpoint; 26 = 26 mm; 30 = USP 3/0 gauge; .2 = double thread 2×75 cm) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (black braided silk coated with wax and silicone, HR26 needle of 26 mm in ½ circle with taper point, USP 3/0 gauge and double-thread assembly 2×75 cm) with published codes from other houses; consult the technical department before using in tendering or direct substitution.
Non-absorbable black braided silk is one of the most standardised natural suture families on the market. As a category guide (not 1:1 interchangeable), in the homologous family B. Braun Silkam® Black codes with the same HR26 needle geometry in adjacent gauges have been verified in the official catalogue —C0760420 (USP 2/0), C0760439 (USP 0) and C0760447 (USP 1), all 75 cm HR26—, but no published code has been found for the exact combination USP 3/0 + HR26 in double-thread assembly; in Ethicon MERSILK™ / PERMA-HAND™ Silk the taper point references in 3/0 mount a longer needle (e.g. W583, 36 mm), outside the ±1 mm tolerance compared to the HR26, so they are not published as a cross-reference.
The homologous families on the market —Ethicon MERSILK™ / PERMA-HAND™ Silk, B. Braun Silkam®, Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Surgisilk™, Serag-Wiessner, SMI Silk Braided and Unilene BLACK BRAIDED SILK— must always be reviewed property by property (material, exact USP/metric gauge, ½ circle curvature, taper point family, needle size within ±1 mm tolerance, number and length of strands, colour, coating and CE/MDR regulatory classification) before any substitution. This needle geometry (HR26, USP 3/0, double thread 2×75 cm) is only fully safely interchangeable within the PREMISUT system itself: the direct equivalent is the single-strand variant of identical geometry and gauge (Ref. P542HR2630, SKU AMP542HR2630) and the standard range version (Ref. 542HR2630, SKU AM542HR2630).
5. Selection tips and variants of interest
USP 3/0 gauge (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucosa and soft tissues with moderate tension, as well as for ligatures and precision approximation in ophthalmology; the taper point Taperpoint penetrates tissue by separating fibres without cutting, which minimises trauma and improves aesthetic outcome.
The double-thread format 2×75 cm is designed for high-volume services or procedures requiring two strands with double needle per unit, reducing the opening of envelopes per intervention. If the volume does not require it, the same geometry and gauge is available in a single 75 cm strand (SKU AMP542HR2630).
| Variant / Reference | Description |
| P542HR2630 / AMP542HR2630 | Silk PREMISUT Prime HR26, USP 3/0, black, 75 cm (single thread, same needle geometry) |
| 542HR2630 / AM542HR2630 | Silk PREMISUT HR26, USP 3/0, black, 75 cm (Normal quality, same geometry) |
| P542HR2620.2 / AMP542HR2620.2 | Silk PREMISUT Prime HR26, USP 2/0, black, 2×75 cm (smaller gauge, same needle profile) |
| P542HR2610.2 / AMP542HR2610.2 | Silk PREMISUT Prime HR26, USP 0, black, 2×75 cm (larger gauge for tension, same profile) |
| P542HR2430.2 / AMP542HR2430.2 | Silk PREMISUT Prime HR24, USP 3/0, black, 2×75 cm (shorter needle reach) |
| P542HR2030 / AMP542RHR2030 | Silk PREMISUT Prime HR20, USP 3/0, black, 2×75 cm (smaller field) |
As this is a sterile single-use product, check the integrity of the pouch before each procedure, respect the expiry date, keep the reference P542HR2630.2 together with the batch number for traceability in the operating theatre, and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.