Description
1. Commercial presentation
The Silk Suture PREMISUT Prime is the premium reference in Cahnos’ range of non-absorbable sutures for professionals who demand a thread of natural origin, exceptional feel and maximum knot security. This double-thread 2×75 cm presentation combines a 100% natural silk multifilament coated with wax and silicone, in high-visibility black, mounted on two ½-circle needles with cylindrical body and 30 mm Taperpoint conical point (HR30 profile), in USP 0 gauge (metric EP 3.5).
Sterile product, ready to use, in a box of 12 individual sachets with full batch traceability. Aimed at general and dermatological surgery services, ophthalmology units, skin surgery and B2B purchasing centres, with special volume conditions for hospitals, clinics and tenders.
2. Technical explanation of the material and procedure
Surgical silk is a natural protein fibre (fibroin, from the cocoon of Bombyx mori) processed to remove natural waxes and gums and presented in a braided multifilament construction, coated with a mixture of wax and silicone. This coating reduces capillarity and bacterial wicking, facilitates the passage of the thread through tissue and ensures a firm, secure knot with the recommended tying technique 2 = 1 = 1 = 1, one of the most valued qualities of surgical silk.
Being a non-absorbable material, the thread does not degrade by hydrolysis: the body gradually encapsulates it with connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The 30 mm HR30 needle features a ½-circle curvature with cylindrical body and Taperpoint conical point: it separates and displaces tissue fibres without cutting them, minimising trauma to delicate, lax or well-perfused structures. The USP 0 gauge (metric EP 3.5) offers balanced strength for medium-tension planes, and the grooved black colour ensures immediate contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range, grooved needle line) |
| Factory reference | P542RHR3010.2 |
| Reference Cahnos (SKU) | AMP542RHR3010.2 |
| Thread material | 100% natural silk (fibroin from Bombyx mori), multifilament |
| Thread structure | Braided (multifilament), fluted surface |
| Coating | Wax and silicone (anti-capillarity, low tissue drag) |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 0 (metric EP 3.5); conforming to USP Pharmacopoeia and European Pharmacopoeia |
| Approximate thread diameter | 0.35 – 0.399 mm (USP Pharmacopoeia range, non-absorbable suture) |
| Thread length | 2 threads of 75 cm each (2×75 cm) |
| Thread colour | Fluted black (high visibility on the surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Taperpoint conical (non-cutting), grooved |
| Needle size | 30 mm (HR30 Prime profile) |
| Swaged | 2 threads of 75 cm, each with a swaged needle (double thread) |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Compliant with USP/EP Pharmacopoeia for non-absorbable sutures; CE/MDR classification |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. Family PREMISUT Prime with HR30 needle (½ circle, Taperpoint conical point) in Cahnos catalogue
| USP size | Presentation | Reference (SKU) |
| 0 | 1 × 75 cm (single strand) | AMP542HR3010 |
| 0 | 2 × 75 cm (double thread) | AMP542RHR3010.2 (this product) |
| 1 | 1 × 75 cm | AMP542HR3001 |
| 1 | 2 × 75 cm | AMP542RHR3001.2 |
| 2/0 | 1 × 75 cm | AMP542HR3020 |
| 2/0 | 2 × 75 cm | AMP542RHR3020.2 |
| 3/0 | 1 × 75 cm | AMP542HR3030 |
| 3/0 | 2 × 75 cm | AMP542RHR3030.2 |
4. Equivalences and Cross-References
The reference P542RHR3010.2 corresponds to the official nomenclature of the PREMISUT Prime range (HR30 profile: ½-circle needle with 30 mm Taperpoint conical point, USP 0 gauge, 75 cm grooved black thread, double-thread configuration 2×75 cm) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Non-absorbable braided black silk is one of the most standardised natural suture families on the market (commercial types Silkam®, MERSILK®/PERMA-HAND™ Silk or DemeSILK™). The references from other manufacturers detailed below have been checked against the manufacturer’s official catalogue and the GUDID/FDA regulatory database; as they are another brand, they do not constitute exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU and CE/MDR classification before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Silkam® Black — natural braided coated multifilament silk, black thread | C0760480 — SILKAM BLACK 0 (3.5) 75 CM HR30 (verified in official B. Braun catalogue and GUDID/FDA) | Comparable by category (not interchangeable 1:1) | They match on material (coated braided silk), USP 0 gauge (EP 3.5), black colour, ½-circle curvature, 30 mm HR30 conical-point needle and 75 cm thread length. They differ in configuration (1 thread with 1 needle vs. double thread 2×75 cm), exact coating (wax/paraffin vs. wax and silicone), sterilisation method (gamma radiation vs. ethylene oxide) and commercial format (box of 36 vs. 12). Confirm IFU before substituting. |
| Ethicon (Johnson & Johnson MedTech) | PERMA-HAND™ Silk / MERSILK® — coated black braided silk, non-absorbable | W334H — PERMA-HAND Silk black braided, USP 0, 75 cm, MH-1 needle of ½ circle taper point (verified in GUDID/FDA) | Comparable by category (not interchangeable 1:1) | They match on material (coated braided silk), USP 0 gauge, black colour, 75 cm length, ½-circle curvature and conical-point family. The 31 mm MH-1 needle falls within the ±1 mm tolerance of the 30 mm HR30. They differ in configuration (1 strand vs. 2×75 cm), exact coating (wax, with no declared silicone) and commercial format (box of 36). Confirm IFU and CE/MDR classification before substituting. |
There is no manufacturer-validated equivalence table cross-referencing this specific configuration (black braided silk, 30 mm HR30 needle in ½ circle with conical point, USP 0 gauge and double 75 cm strand) with references from other manufacturers. Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle size, length and number of strands, colour, coating and CE/MDR regulatory classification) before any substitution are: DemeTECH DemeSILK™, Medtronic Sofsilk™, LOOK™ Silk (Corza Medical), Assut Surgisilk™, Serag-Wiessner, SMI Silk Braided, Unilene SEDA NEGRA TRENZADA and Clarben Octosutur Seda. This needle geometry (HR30 Prime, USP 0, double thread 2×75 cm) is only fully safely interchangeable within the PREMISUT system itself. Consult the technical department before use in tenders.
5. Selection tips and variants of interest
Tissue to suture: the USP 0 gauge (metric EP 3.5) provides balanced strength for subcutaneous tissue, skin, fasciae and soft tissues of medium tension, always with a conical-point needle to minimise tissue damage. For finer or paediatric planes, it can be reduced to USP 2/0 (Ref. AMP542RHR3020.2) or USP 3/0 (Ref. AMP542RHR3030.2), and for higher-tension planes increased to USP 1 (Ref. AMP542RHR3001.2) within the same HR30 geometry in double thread.
Double-thread configuration: the 2×75 cm presentation (Ref. P542RHR3010.2) provides two needle-mounted strands in a single package, ideal for continuous sutures, multi-point sutures or for distributing material across two surgical fields without opening additional sachets. If you prefer a single strand, the same range offers the HR30 profile in 1×75 cm (Ref. AMP542HR3010).
Prime quality vs. standard: the Prime range provides maximum sharpening precision and batch-to-batch consistency; if cost per unit is a critical factor, the standard range of identical geometry and gauge (Ref. AM542HR3010) maintains the same dimensional specifications with standard sharpening performance.
Needle length: the HR30 profile of 30 mm covers shallow to medium-depth access and is ideal for small fields in skin surgery, ophthalmology and lax tissues. For deeper fields, the same range offers the HR37 profile in USP gauge 0 (Ref. AMP542HR3710), allowing a single supplier to be used across the entire PREMISUT Prime silk family.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P542RHR3010.2 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.