Description
1. Commercial Introduction
We offer you the braided silk suture from the PREMISUT Prime range, reference P542HR2420.2 (SKU AMP542HR2420.2), a professional solution for B2B supply of operating theatres, general and specialised surgery departments, ophthalmology units, skin surgery and hospital purchasing centres.
This double-strand presentation incorporates 2 black strands of 75 cm in USP 2/0 gauge, mounted on a ½ circle needle with a cylindrical body and a fluted conical point of 24 mm (HR24 profile). A classic and versatile configuration for approximating soft tissues, ligatures and moderate-tension closures, with the knot handling and security characteristic of surgical silk. It is supplied in a box of 12 sterile units, ready for immediate use.
2. Technical explanation
Surgical silk is a multifilament material of natural origin (fibroin protein from the Bombyx mori cocoon) braided over a twisted core and coated with a thin layer of wax and silicone. This coating reduces the capillarity and wicking effect of the multifilament and facilitates the sliding of the strand through the tissue with less friction, resulting in less tissue trauma and better handling during knotting (recommended technique 2 = 1 = 1 = 1).
Being non-absorbable, the strand does not degrade by hydrolysis or enzymes: a gradual encapsulation of the material occurs, maintaining tensile strength and approximation integrity for more than three months, comfortably covering the critical healing phase. The ½ circle needle with a cylindrical body and conical point (Taperpoint) of 24 mm separates tissue fibres instead of cutting them, minimising trauma to soft and delicate tissues such as skin and ocular structures. The black fluted colour ensures optimal contrast on the surgical field. Each strand is sterilised by ethylene oxide (EO); single-use product and not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | P542HR2420.2 (suffix .2 = double-strand presentation) |
| SKU Cahnos | AMP542HR2420.2 |
| Brand / quality | PREMISUT Prime (premium range, grooved needle) |
| Thread material | 100% natural silk (fibroin), multifilament braided over a twisted core |
| Thread structure | Braided (multifilament), fluted surface |
| Coating | Wax and silicone (anti-capillarity, low drag) |
| Absorption type | Non-absorbable; gradual encapsulation, support for more than 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforms to USP and European Pharmacopeia |
| Approximate thread diameter | 0.30 – 0.349 mm (non-absorbable suture, USP Pharmacopeia) |
| Configuration | 2 strands (double needle) of 75 cm each (2×75 cm; 150 cm per packet) |
| Thread colour | Fluted black (high visibility on the surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical grooved (Taperpoint) |
| Needle size | 24 mm (HR24 Prime profile) |
| Swaged | 2 strands with needle per unit (one needle per strand) |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for sterile non-absorbable sutures |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 (this product) | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
The reference P542HR2420.2 corresponds to the official nomenclature of the PREMISUT Prime range (HR24 profile: ½ circle needle with cylindrical body and taperpoint conical point of 24 mm, USP 2/0 gauge, black braided strand of 75 cm and double-strand configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (black coated braided silk, ½ circle needle with conical point of 24 mm, USP 2/0 gauge and double-strand presentation 2×75 cm) with published codes from other houses; consult the technical department before using in tendering or direct substitution. The homologous families of black non-absorbable braided silk on the European market —B. Braun Silkam® (½ circle needle with round body taper point; their HR 22 and HR 26s range is the closest to the 24 mm of this reference), Ethicon MERSILK® (½ circle cylindrical needles SH-1/CT-3 of 22 mm and SH/CT-2 of 26 mm), Medtronic Sofsilk™, DemeTECH DemeSILK™ and the braided silks from Surgical Specialties— must be reviewed property by property (USP/metric gauge, ½ circle curvature, conical point or taper point geometry, needle measurement of 24 mm within tolerance ±1 mm, number and length of strands, colour, coating and CE/MDR regulatory classification) before any substitution. This needle geometry (HR24, USP 2/0, double strand) is only interchangeable with full safety within the PREMISUT system itself.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric EP 3) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucosa and soft tissues with moderate tension, as well as for ligatures and precision approximation in ophthalmology; the taperpoint conical point passes through the tissue separating the fibres without cutting, which minimises trauma and improves the aesthetic result.
Select the needle length according to the surgical field: the HR24 of 24 mm is a very manageable intermediate size; for smaller fields you have the same Silk family in HR17 and HR20, and for greater reach in HR26, HR30, HR37, HR40 and HR48 within the PREMISUT catalogue. The double-strand format 2×75 cm is designed for high-volume services or procedures requiring two strands with double needle per unit, reducing the opening of packets per intervention.
Variants of interest within the Cahnos catalogue:
| Variant / Reference | Description |
| P542HR2420 / AM542HR2420 | Silk PREMISUT HR24, USP 2/0, black, 75 cm (single strand, Prime / standard quality) |
| P542RHR2430.2 | Silk PREMISUT Prime HR24, USP 3/0, black, 2×75 cm (finer gauge, same needle profile) |
| P542HR2430 / 542HR2430 | Silk PREMISUT HR24, USP 3/0, black, 75 cm (single strand) |
| 542HR2630 | Silk PREMISUT HR26, USP 3/0, black, 75 cm (slightly more needle reach) |
As it is a sterile single-use product, check the integrity of the packet before each procedure, respect the expiry date, keep the reference P542HR2420.2 together with the lot number for traceability in the operating theatre and store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.