Description
1. Commercial Introduction
The Silk Suture PREMISUT 1/2 Triangular HS26 is the classic reference for non-absorbable natural-origin thread for professionals who demand exceptional handling, reliable knotting and predictable behaviour in soft tissue closure. This presentation mounts a ½ circle needle with a 26 mm reverse cutting triangular point (HS26 profile), USP 0 gauge (metric EP 3.5) and 75 cm of black grooved thread, coated with wax and silicone to reduce friction and facilitate sliding through tissue.
Designed for the operating theatre, ophthalmology practice, dermatological surgery and minor surgery, it is presented in a box of 12 individual sterile sachets, ready to use and with full batch traceability. It is the continuous replenishment solution for surgical services, purchasing centres and B2B contracts.
2. Technical explanation of the material and procedure
Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating minimises the capillarity of the multifilament, reduces drag when passing through tissue and improves knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.
Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HS26 needle of 26 mm has a ½ circle curvature with a reverse cutting triangular body and point (reverse cutting): the cutting edge is oriented towards the outside of the curvature, so it passes through skin and firm tissues without enlarging the puncture bed, minimising trauma and improving the aesthetic result. The black grooved colour guarantees optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | 542HS2610 |
| Reference Cahnos (SKU) | AM542HS2610 |
| Brand / quality | PREMISUT (standard range) |
| Thread material | 100 % natural silk (fibroin from Bombyx mori), multifilament |
| Thread structure | Braided (multifilament), fluted surface |
| Coating | Wax and silicone (anti-capillarity, low drag) |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP Pharmacopoeia and European Pharmacopoeia |
| Approximate thread diameter | 0.35 – 0.399 mm (USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Fluted black (high visibility on the surgical field) |
| Needle shape | ½ circle (1/2 circular), body and triangular point |
| Tip type | Reverse cutting triangular (reverse cutting) |
| Needle size | HS26 (26 mm) |
| Swaged | 1 swaged needle per thread |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets); minimum order of 30 boxes |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. PREMISUT Silk HS26 family (½ circle needle, 26 mm, reverse cutting triangular point, black thread)
| USP size | Thread | Factory reference | SKU Cahnos |
| 3/0 | 1 × 75 cm (black) | 542HS2630 | AM542HS2630 |
| 2/0 | 1 × 75 cm (black) | 542HS2620 | AM542HS2620 |
| 0 | 1 × 75 cm (black) | 542HS2610 | AM542HS2610 (this product) |
4. Equivalences and Cross-References
The reference 542HS2610 corresponds to the official nomenclature of the PREMISUT range (542 = 75 cm thread; HS = ½ circle needle with reverse cutting triangular point; 26 = 26 mm; 10 = USP 0 gauge) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Non-absorbable coated black braided silk is one of the most standardised natural suture families on the market. The cross-reference detailed below shares material, gauge, colour, thread length, ½ circle curvature, reverse cutting point family and needle size, and has been checked against the manufacturer’s official catalogue and the GUDID regulatory database; as it is another brand, it does not constitute exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | SILKAM® Black – natural silk multifilament braided and coated (wax/paraffin), USP 0 (EP 3.5), 75 cm, HS26 needle | C0762431 (verified in official B. Braun catalogue and in GUDID: SILKAM BLACK 0 (3.5) 75CM HS26) | Comparable by category (not interchangeable 1:1) | They match in material (braided and impregnated natural silk), USP 0 gauge (metric EP 3.5), black colour, 75 cm length, ½ circle curvature, reverse cutting point family and HS26 needle size (26 mm). They differ in coating (wax/paraffin in Silkam versus wax and silicone in PREMISUT), sterilisation system (radiation versus ethylene oxide) and dispensing packaging. |
There is no equivalence table validated by the manufacturer (PREMISUT) for this configuration; the indicated cross-references are offered at the level of technical data sheet comparison and must be confirmed with the technical department before use in tendering. Other homologous families of black non-absorbable braided silk present in the European market — Ethicon MERSILK® / PERMA-HAND™ Silk (Johnson & Johnson MedTech), Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Assusilk®, Lorca Marín Seda Trenzada, Laboratorio Aragó, Unilene and Serag-Wiessner, among others — must always be checked reference by reference: USP/metric gauge, length and number of threads, geometry and exact needle size, colour, coating and CE/MDR regulatory classification before proceeding to any substitution.
5. Selection tips and variants of interest
Tissue to suture: USP 0 gauge (metric EP 3.5) offers the optimal balance between strength and handling for skin, subcutaneous tissue, oral mucosa and soft tissues with moderate tension, as well as ligatures and drain fixation; the HS26 reverse cutting needle passes through firm tissues without tearing the puncture bed. For more delicate planes (face, precision surgery) consider USP 3/0 with the same HS26 needle (AM542HS2630); for lower mechanical demand, USP 2/0 (AM542HS2620).
Needle geometry: if you need greater needle reach in the same USP 0 gauge, the HS36 profile of 36 mm (AM542HS3610) is available. If you work on very lax tissues and seek less trauma, consider the ½ circle variant with conical point HR26 (AM542HR2610) or the ⅜ circle with reverse cutting DS26 (AM542DS2610), both in USP 0 gauge.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep reference 542HS2610 together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight (below 30 °C). For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.