Polypropylene suture Premisut Prime 4/0: precision and reliability in every stitch
The non-absorbable polypropylene suture PREMISUT PRIME is the reference choice in operating theatres that demand a thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating firm tissues with total precision. Its monofilament configuration, its highly visible blue colour and its 16 mm XDS precision cutting needle make it an excellent option for skin closures, plastic and cosmetic surgery, and specialties where every pass counts.
What it is and how it works
Polypropylene is a synthetic linear polyolefin that is presented in the form of uncoated monofilament. As it lacks interstices, it offers very smooth sliding, does not favour tissue adhesion and minimises the formation of sinuses or extrusion of the thread in wounds at risk of contamination. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength permanently, exceeding the requirements of USP and EP standards, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The XDS needle (⅜ circle, extra-long precision reverse cutting triangular point and square body) is indicated for firm tissues and plastic and cosmetic applications, where the controlled cutting geometry reduces trauma and allows a clean and stable passage. The non-grooved (non-channeled) presentation favours a smooth and consistent delivery of the thread during knotting.
Technical specifications
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Absorption | Non-absorbable (permanent tensile strength retention; gradual encapsulation) |
| Gauge | USP 4/0 |
| Thread length | 75 cm |
| Thread colour | Identification blue |
| Needle shape | ⅜ circle |
| Needle type | Triangular precision point, extra-long reverse cutting (XDS profile) |
| Needle body / measurement | Square body, 16 mm (XDS 16 Prime profile) |
| Thread presentation | Non-grooved (non-channeled) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, sterile |
| Presentation | Box of 12 units |
| Factory reference | AMP732XDS1640 |
Indications for use: approximation of soft tissues and general ligatures, including cardiovascular surgery, ophthalmology, neurosurgery, oral surgery, gynaecology, orthopaedics and plastic and cosmetic surgery.
Equivalences and cross-references
The code AMP732XDS1640 corresponds to the manufacturer’s official nomenclature (PREMISUT range, XDS 16 Prime profile). Cahnos keeps the reference without altering characters: do not add, remove or reorder digits when ordering or bidding. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional and must be confirmed against the technical data sheet or the instructions for use of each manufacturer before use in tendering or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range | Polypropylene XDS 16 Prime 4/0 blue 75 cm | AMP732XDS1640 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range | Polypropylene XNS 16 Prime 4/0 blue 75 cm, conventional cutting | AMP732XNS1640 | Comparable by category, not interchangeable 1:1 | Same gauge, length and 16 mm square body, but conventional cutting point versus precision reverse cutting. Verify geometry according to the tissue. |
| Premisut Prime range | Polypropylene DS 16 Prime 4/0 blue 75 cm | AMP732DS1640 | Comparable by category, not interchangeable 1:1 | Same gauge, same length and 16 mm, but DS needle profile (standard reverse cutting) versus XDS (extra-long precision reverse cutting with square body). Verify geometry according to the tissue. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® (blue monofilament polypropylene) | Check exact reference | Comparable at category level, not interchangeable 1:1 | Non-absorbable polypropylene monofilament, blue. Differences in needle geometry, commercial lengths (45/75/90 cm) and presentations. No official cross-reference table with the Premisut range. |
| SERAG-WIESSNER | SERAPREN® blue | Check specific reference | Comparable at category level, not interchangeable 1:1 | Blue non-absorbable polypropylene monofilament. Verify gauge, needle geometry and lengths with the distributor |
| Medtronic (Covidien) | Surgipro™ | Check specific reference | Comparable at category level, not interchangeable 1:1 | Non-absorbable polypropylene with polyethylene monofilament. Verify needle, gauge and presentation. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using it as a substitute in tendering or substitution.
Selection tips and variants of interest
Tissue to suture: the XDS extra-long cutting needle with square body is suitable for firm tissues, skin and cosmetic surgery; for looser or vascular tissues, consider round point profiles from the same range.
Gauge: USP 4/0 is a fine and versatile gauge for skin planes and soft tissues; for even finer planes (facial skin, microsurgery) consider 5/0 or 6/0 from the same XDS family, and for fasciae or higher-tension ligatures, larger gauges.
Thread length: 75 cm is the usual operating theatre measure; a 45 cm length is also available in the same configuration.
XDS family variants available at Cahnos:
| Reference | Needle | USP | Length | Colour |
| AMP732XDS1640 | XDS 16 mm | 4/0 | 75 cm | Blue |
| AMP732XDS1340 | XDS 13 mm | 4/0 | 75 cm | Blue |
| AMP732XDS1940 | XDS 19 mm | 4/0 | 75 cm | Blue |
| AMP732XDS1650 | XDS 16 mm | 5/0 | 75 cm | Blue |
| AMP732XDS1660 | XDS 16 mm | 6/0 | 75 cm | Blue |
| AMP731XDS1640 | XDS 16 mm | 4/0 | 45 cm | Blue |
| AMP732XDS2620 | XDS 26 mm | 2/0 | 75 cm | Blue |
Expiry and sterility verification: sterile product by ethylene oxide, single use; check the integrity of the blister and the expiry date before each use.
Compatibility and traceability: keep the reference AMP732XDS1640 and the batch number for traceability in the operating theatre and in the event of a claim.