Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, aesthetic surgery clinics, purchasing centres and tenders that require a non-absorbable suture with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP 4/0 gauge mounts a ⅜ circle needle with a triangular point of extra-long precision conventional cutting and 19 mm square body (XNS 19 Prime profile) on a 45 cm blue thread: the classic format for skin closure, approximation of soft tissues and techniques of plastic surgery, cosmetic surgery, ophthalmology, neurosurgery and cardiovascular surgery.
Sterile product, single-use and with complete traceability by batch, presented in a box of 12 units in individual sachets. Cahnos markets it under the factory reference P731XNS1940 (SKU AMP731XNS1940), kept without altering characters: no digit may be added, removed or reordered when ordering or tendering.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin ([C₃H₆]ₙ) that is presented as an uncoated monofilament dyed blue. As it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength permanently, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The XNS needle (⅜ circle, triangular point with extra-long precision conventional cutting, conventional extra cutting profile) presents the cutting edge on the internal curvature of the triangular point and a long cutting edge that passes through skin, mucosa and fibrous planes with a clean and controlled path. The square body improves grip in the needle holder, prevents needle rotation and allows a stable passage without tearing: a geometry especially valued in aesthetic skin closure where scar quality is a priority. The non-grooved presentation favours a smooth and consistent delivery of the thread during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (official Cahnos price list).
| Parameter | Specification |
| Brand / Line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-grooved surface (without grooves) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 4/0 (EP metric 1.5); diameter 0.15 – 0.199 mm (USP Pharmacopoeia) |
| Thread length | 45 cm (1 thread with 1 needle per unit) |
| Thread colour | Identification blue (high visibility) |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle type | Triangular point, extra-long precision conventional cutting (XNS profile) |
| Needle size | 19 mm (XNS 19 Prime profile) |
| Needle body | Square (maximum stability in the needle holder) |
| Manufacturing quality | Prime (premium finish, improved penetration) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, neurosurgery, oral surgery, gynaecology, orthopaedics and plastic/cosmetic surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P731XNS1940 |
| Reference Cahnos (SKU) | AMP731XNS1940 |
4. Equivalences and Cross-References
The reference P731XNS1940 corresponds to the official nomenclature of the Premisut Prime range (XNS 19 Prime profile, ⅜ needle with triangular point of precision conventional cutting with 19 mm square body, USP 4/0 gauge and 45 cm blue thread). There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. This XNS needle geometry (precision conventional cutting with square body) is only safely interchangeable within the Premisut system itself.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | PROLENE® Precision Cosmetic – Conventional Cutting PRIME, PC-3 needle (precision conventional cutting, 3/8 circle, 16 mm, PRIME body) | 8634G | Comparable by category (not interchangeable 1:1) | Code cited in the catalogue of the Premisut family by specifications against Ethicon: blue monofilament polypropylene 4/0, 45 cm and precision conventional cutting point; PC-3 needle of 16 mm versus XNS 19 mm. Confirm batch, presentation and IFU |
| Ethicon (J&J MedTech) | PROLENE® PC-25 PRIME™ (precision conventional cutting, 3/8 circle, 26 mm) | W8020T | Comparable by category (not interchangeable 1:1) | Blue monofilament polypropylene 4/0, 45 cm, precision conventional cutting; 26 mm needle versus XNS 19 mm and different commercial presentation (box of 24 units). Confirm IFU |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, Easyslide DS16 needle (3/8 circle) | C2090213 | Comparable by category (not interchangeable 1:1) | PREMILENE 4/0 (1.5) 45 cm verified in B. Braun catalogue: same base material, gauge and length; the DS16 needle is reverse cutting (approx. 16 mm) versus the XNS conventional cutting of 19 mm. Confirm geometry and presentation |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, 4/0 blue, PC-11 needle (3/8, conventional cutting, 16 mm) | SP-1634 | Comparable by category (not interchangeable 1:1) | Same gauge, colour and 45 cm with conventional cutting needle of 16 mm; copolymer material (not pure polypropylene) and needle of shorter length than the XNS 19. Confirm reference, batch and IFU |
There is no equivalence table validated by the manufacturer that cross-references the reference P731XNS1940 with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet or the IFU of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the XNS needle with precision conventional cutting and square body is indicated for skin, mucous membranes and soft tissues with low distensibility where a clean entry hole and an aesthetic scar are sought (plastic and cosmetic surgery, ophthalmology, neurosurgery). For firm or low-distensibility tissues, consider the XDS reverse cutting profile from the same range, and for lax or vascular tissues, conical point profiles (HR series).
Gauge: USP 4/0 (metric 1.5) offers an optimal balance between fineness and strength for skin and soft tissue planes. For even finer planes (facial skin, microsurgery), consider the 5/0 or 6/0 from the same XNS family; for fasciae or ligatures under higher tension, larger gauges.
Thread length: 45 cm is ideal for precision procedures with controlled handling; the same XNS 19 Prime 4/0 configuration is also available in a 75 cm length (AMP732 series).
Variants of the XNS family in Prime polypropylene (blue) at Cahnos: AMP731XNS1640 (XNS 16 mm, 4/0, 45 cm), AMP732XNS1640 (XNS 16 mm, 4/0, 75 cm), AMP731XNS1940 (XNS 19 mm, 4/0, 45 cm – this product), AMP732XNS1940 (XNS 19 mm, 4/0, 75 cm), AMP731XNS1950 (XNS 19 mm, 5/0, 45 cm), AMP731XNS1650 (XNS 16 mm, 5/0, 45 cm), AMP731XNS2640 (XNS 26 mm, 4/0, 45 cm) and AMP731XNS2630 (XNS 26 mm, 3/0, 45 cm). Consult each datasheet to confirm gauge, length and needle geometry before ordering.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P731XNS1940 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews