We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Polypropylene suture Premisut Prime non-absorbable, double ⅜ circle trocar point needle 2xDRT17 mm, USP 4/0, blue, 2 threads of 90 cm (Ref. P733DRT1740-2) | Box of 12 units

72,59 €

Polypropylene suture Premisut Prime, non-absorbable and uncoated monofilament, presented with double ⅜ circle trocar point needle 17 mm (2xDRT17 Prime), USP 4/0 and blue thread 90 cm. Ideal for approximation of soft tissues, ligatures, and cardiovascular surgery, ophthalmology and neurosurgery, with wound support for more than three months. Sterilised by ethylene oxide and single-use, supplied in a box of 12 units with batch traceability. Factory reference P733DRT1740-2 (SKU AMP733DRT1740-2) for centralised purchasing and tenders.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP733DRT1740-2

Description

1. Commercial Introduction

The polypropylene suture Premisut Prime is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating moderately firm tissues with full control. This presentation in gauge USP 4/0, with double ⅜ circle needle with 17 mm trocar point (2xDRT17 Prime profile) and two 90 cm blue threads, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.

Supplied sterile and ready for single use in a box of 12 units with batch traceability, facilitating hospital stock management and submission to public tenders. Available at Cahnos under the factory reference P733DRT1740-2 (SKU AMP733DRT1740-2), kept unchanged.

2. Technical Explanation

Polypropylene is a synthetic linear polyolefin presented as uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or sinus formation in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over time, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.

The DRT 17 Prime needle (⅜ circle, cylindrical body with 17 mm Tapercut-type trocar point) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without severing them: it passes through dense or slightly fibrous tissues with less resistance and without a cutting effect on adjacent tissue, reducing trauma and bleeding. The double-needle configuration allows continuous sutures or bilateral techniques without repositioning the needle in the needle holder. Sterilised by ethylene oxide (EO); single-use product, not resterilisable.

3. Technical Specifications

Parameter Specification
Thread material Polypropylene monofilament, uncoated, dyed blue
Thread structure Non-grooved monofilament
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges
Thread length 2 threads of 90 cm (2 × 90 cm) per unit
Thread colour Identification blue
Needle shape ⅜ circular (3/8 circle)
Needle body Cylindrical
Tip type Trocar (Tapercut)
Needle size 17 mm (profile 2xDRT 17 Prime)
Configuration Double needle (2xDRT)
Manufacturing quality Prime (premium range)
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (individual sterile sachets)
Factory reference P733DRT1740-2
Reference Cahnos (SKU) AMP733DRT1740-2

DRT 17 family (⅜ circle trocar point) in USP 4/0 gauge:

Needle profile Presentation Reference
2xDRT 17 Prime 2 × 90 cm P733DRT1740-2
2xDRT 17 Prime 2 × 75 cm AMP732DRT1740-2
DRT 17 Prime 1 × 75 cm P732DRT1740 / AMP732DRT1740

4. Equivalences and Cross-References

The reference P733DRT1740-2 corresponds to the official nomenclature of the Premisut Prime range (2xDRT 17 Prime profile, double 90 cm thread). Cahnos markets the product keeping the factory reference unchanged. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Premisut Prime range (Cahnos) Polypropylene 2xDRT 17 Prime, USP 4/0, blue, 2 × 90 cm P733DRT1740-2 / AMP733DRT1740-2 Direct product reference Product analysed in this data sheet
Premisut Prime range (Cahnos) Polypropylene 2xDRT 17 Prime, USP 4/0, blue, 2 × 75 cm AMP732DRT1740-2 Configuration equivalent within the same system Same 2xDRT 17 needle and USP 4/0 gauge; length changes to 2 threads of 75 cm
Ethicon (Johnson & Johnson MedTech) PROLENE® – blue monofilament polypropylene, USP 4/0, 90 cm, V-4 17 mm 3/8 circle Tapercut needle 8925H Functional equivalence by specifications (no official cross-reference table) Matches in material, gauge, colour, thread length and needle geometry (17 mm, 3/8, trocar point). Presentation in box of 36 units; confirm batch and presentation against IFU
Ethicon (Johnson & Johnson MedTech) PROLENE® – blue polypropylene, double needle 1/2 circle trocar point 17 mm, USP 4/0, 90 cm ETH8954G (confirm local code with authorised distributor) Comparable by category / not interchangeable 1:1 Same 17 mm trocar point, gauge and length; arc changes to 1/2 circle (different passage geometry)
B. Braun Premilene® (blue polypropylene monofilament, Easyslide needles) C209xxxx line – pending confirmation of 1:1 code for 2xDRT17 USP 4/0 90 cm (e.g. C2090902 in HR17 profile) Comparable by category / pending confirmation Same blue polypropylene base; verify point profile (trocar vs. conical) and arc in the manufacturer’s technical data sheet
Medtronic (Covidien) Surgipro™ II (polypropylene with polyethylene, blue monofilament) VP925X (tapercut 4/0, blue, 36″, KV-15 3/8 circle needle) – confirm in tender Comparable by category / pending confirmation Copolymer with polyethylene; matches in gauge, length and needle family; verify exact needle size and presentation against IFU
Serag-Wiessner SERAPREN® (blue polypropylene monofilament, USP 8/0 to 0) Blue Serapren, metric 1.5, USP 4/0, 90 cm, 2x DR-17 (consult order code according to catalogue) Comparable by category / pending confirmation Very close 2x DR-17 profile (double 17 mm trocar needle); confirm needle arc and official code with the distributor

Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ II or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department at Cahnos to validate any equivalence before substituting the product.

5. Selection tips and variants of interest

  • Tissue to suture: the DRT trocar-point (Tapercut) needle is suitable for moderately firm or slightly fibrous tissues requiring firm penetration with minimal aggression (skin, mucosa, subcutaneous tissue, ophthalmology and vascular planes). For very friable tissues, consider conical-point (HR) profiles from the same Premisut Prime range.
  • Needle size: the 17 mm DRT is a medium-length needle, ideal for reduced surgical fields; for wider planes, the 25 mm DRT family is available in other gauges within the Premisut catalogue.
  • Gauge: USP 4/0 (metric 1.5) offers the balance between strength and manageability for fine tissues under moderate tension; for less demanding planes consider USP 5/0 (AMP732DRT1750) or, for greater support, USP 3/0 (AMP732DRT1730) with the same DRT 17 needle.
  • Presentation: the 2 × 90 cm version reduces the number of packages opened per procedure compared to the single-thread version (P732DRT1740, 1 × 75 cm) and provides greater useful length for continuous sutures.
  • Sterility verification: sterile product by ethylene oxide, single-use; check the blister integrity and expiry date before each use and keep the reference P733DRT1740-2 and the batch number for traceability in the operating theatre and in case of complaint.

Additional information

Material

Uncoated monofilament polypropylene

Structure

Non-grooved monofilament

Absorption

Non-absorbable; gradual encapsulation, support for more than 3 months

Gauge

USP 4/0 (metric EP 1.5)

Needle type

Cylindrical trocar point (Tapercut)

Needle size

17 mm

Needle profile

2xDRT 17 Prime

Needle configuration

Double needle (2xDRT)

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Indications

Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery

Manufacturer reference

P733DRT1740-2

Medida de aguja

2xDRT 17 prime

Usp

4/0

Color

Blue

Medida de hilo

2 × 90 cm, 90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Polypropylene suture Premisut Prime non-absorbable, double ⅜ circle trocar point needle 2xDRT17 mm, USP 4/0, blue, 2 threads of 90 cm (Ref. P733DRT1740-2) | Box of 12 units”