We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Non-absorbable polypropylene suture Premisut Prime – Double needle ⅜ circle trocar point Tapercut 2×DRT 5.5 mm, USP 8/0, blue, thread 60 cm | Box of 12 units (Ref. P736DRT5,580-2)

248,94 €

Non-absorbable suture of monofilament polypropylene Premisut Prime in double-needle configuration: two ⅜ circle needles with cylindrical body and trocar point (tapercut) of 5.5 mm (profile 2xDRT 5.5 Prime), USP 8/0 gauge (metric EP 0.4) and blue thread of 60 cm, uncoated and non-grooved. Very smooth sliding, without wicking effect and minimal tissue reaction, with wound support for more than three months. Sterilised by ethylene oxide, single-use, in a box of 12 individual sterile pouches. Indicated for approximation of soft tissues, ligatures and precision surgery in cardiovascular, ophthalmology and neurosurgery. Factory reference P736DRT5,580-2 · SKU AMP736DRT5,580-2. B2B format ideal for tenders and hospital replenishment.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP736DRT5.580-2

Description

1. Commercial Introduction

The Premisut Prime polypropylene suture in double-needle configuration is the choice of the professional seeking a high-performance non-absorbable thread for surgical planes that combine firmness and delicacy. This reference mounts two ⅜ circle needles with cylindrical body and trocar point (tapercut) of 5.5 mm, USP 8/0 gauge and 60 cm blue monofilament thread: a precision configuration designed for approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery.

Sterile, single-use product with batch traceability, presented in a box of 12 units in individual sachets. It is ideal for B2B procurement for hospitals, clinics, purchasing centres and public tenders. It is marketed under the factory reference P736DRT5,580-2 (SKU Cahnos AMP736DRT5,580-2), kept without altering characters.

2. Technical Explanation

Polypropylene is a synthetic linear polyolefin (propylene polymer) that, in monofilament form, behaves as an inert thread with a smooth, non-grooved surface: lacking interstices and wicking effect, it does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.

The ⅜ circle needle with cylindrical body and 5.5 mm trocar point (tapercut) combines the atraumatic penetration of the cylindrical body with a sharp trocar-type cutting point, designed to pass through soft, poorly distensible tissues with minimal trauma. The double-needle configuration (two needles on the 60 cm thread) allows continuous sutures or repositioning of the strand without rethreading, reducing the opening of packages per intervention. The USP 8/0 gauge (EP metric 0.4) is an ultrafine thread ideal for approximating very fine tissues. Sterilisation is carried out using ethylene oxide (EO); the product is single-use and not re-sterilisable.

3. Technical Specifications

Data verified according to the technical data sheet and instructions for use of the distributor (Cahnos S.L.).

Parameter Specification
Brand / Quality Premisut Prime (premium range)
Thread material Polypropylene monofilament, uncoated, dyed blue
Thread structure Smooth monofilament, non-grooved
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 8/0 (metric EP 0.4); conforming to USP and European Pharmacopoeia gauges
Thread diameter 0.040 – 0.049 mm (according to USP, non-absorbable suture)
Thread length 60 cm (double needle configuration)
Thread colour Identification blue (high visibility in the surgical field)
Needle shape ⅜ circular (3/8 circle)
Needle type Cylindrical body with trocar point (tapercut)
Needle size 2 × 5.5 mm (2xDRT 5.5 Prime profile)
Configuration Double needle (2 needles on 60 cm thread)
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability
Factory reference P736DRT5,580-2
Reference Cahnos (SKU) AMP736DRT5,580-2

Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture):

USP size EP metric measure Thread diameter (mm) Thread length
8/0 0.4 0.040 – 0.049 60 cm (double needle)

4. Equivalences and Cross-References

The reference P736DRT5,580-2 corresponds to the official nomenclature of the Premisut Prime range (2xDRT 5.5 Prime profile, trocar point, double needle, 60 cm blue thread). Cahnos markets the product keeping the factory reference without altering characters. Non-absorbable monofilament polypropylene is one of the most widespread permanent suture families in the surgical market; the reference commercial ranges are PROLENE® (Ethicon / Johnson & Johnson MedTech), Premilene® and Optilene® (B. Braun), Surgipro™ (Medtronic / Covidien) and SERAPREN® (Serag-Wiessner). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) PROLENE® – blue monofilament polypropylene, USP 8/0, blue, 24″ (60 cm), double needle, BV175-6 ⅜ circle needle with conical taper point 8741H Comparable by category (not interchangeable 1:1) Code confirmed in the Ethicon product centre and authorised distribution: material, 8/0 gauge, blue colour, double needle and 60 cm length match; conical taper point needle (BV175-6) versus 5.5 mm trocar point; confirm point geometry and presentation against IFU
Ethicon (J&J MedTech) PROLENE® – blue monofilament polypropylene, USP 8/0, blue, 13 cm, BV130-5 ⅜ circle needle, conical point W2775 Comparable by category (not interchangeable 1:1) Code confirmed in the Ethicon product centre and authorised distribution: same material, gauge, colour and ⅜ needle geometry; single BV130-5 needle and 13 cm thread versus double 5.5 mm trocar needle and 60 cm; confirm point against IFU
B. Braun Optilene® – blue monofilament of polypropylene and polyethylene, USP 8/0 (EP 0.4), 60 cm, double ⅜ circle needle with round point (2xDR08) C3097887 Comparable by category (not interchangeable 1:1) Code confirmed in the official B. Braun catalogue: gauge, colour, 60 cm length and double-needle configuration match; PP+PE copolymer material (not pure polypropylene) and round point needle versus 5.5 mm trocar point; confirm geometry against IFU

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the comparisons with PROLENE® and Optilene® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. This needle geometry (2xDRT 5.5 trocar point, USP 8/0, 60 cm) is only safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence before substituting the product.

5. Selection tips and variants of interest

Tissue to suture: the cylindrical-body trocar point (tapercut) needle is indicated for soft, poorly distensible tissues and vascular structures where a firm passage with minimal trauma is sought. For planes requiring penetration with more marked cutting, consider reverse cutting profiles from the same Premisut range; for very lax and purely atraumatic tissues, the taperpoint conical point range (DR profile) is the natural alternative.

Gauge: USP 8/0 (EP metric 0.4) is an ultrafine gauge intended for microsurgery and approximation of delicate tissues. If finer is required, consider the same family in USP 9/0 and 10/0 from the Premisut Prime range (DR profiles with conical point); if more strength is required, the higher gauge maintains the same excellent monofilament handling.

Double-needle presentation: provides two 5.5 mm needles on a 60 cm thread, ideal for continuous sutures, cardiovascular surgery and double-anchoring techniques without opening a second package. Always verify the needle geometry (3/8 trocar versus conical, spatulated or straight), USP gauge, length and presentation required in your protocol before placing the order.

Sterility verification: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P736DRT5,580-2 and the batch number for traceability in the operating theatre and in case of complaint. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.

Additional information

Brand

Premisut Prime (premium range)

Material

Polypropylene monofilament, uncoated, dyed blue

Structure

Smooth monofilament, non-grooved

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

8/0 (metric EP 0.4); conforming to USP and European Pharmacopoeia gauges

Thread diameter

0.040 – 0.049 (according to USP, non-absorbable suture)

Thread length

60 cm (double needle configuration)

Thread colour

Identification blue (high visibility in the surgical field)

Needle shape

⅜ circular (3/8 circle)

Needle type

Cylindrical body with trocar point (tapercut)

Needle size

2 × 5.5 mm (2xDRT 5.5 Prime profile)

Configuration

Double needle (2 needles on 60 cm thread)

Sterilisation

Ethylene oxide (EO) – sterile

Use

Single-use, sterile. Do not re-sterilise

Presentation

Box of 12 units (sterile individual sachets); batch traceability

Manufacturer reference

P736DRT5,580-2

Indications

Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery

Medida de aguja

2 × 5.5 mm, 2xDRT 5.5 prime

Usp

8/0

Color

Blue

Medida de hilo

60 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable polypropylene suture Premisut Prime – Double needle ⅜ circle trocar point Tapercut 2×DRT 5.5 mm, USP 8/0, blue, thread 60 cm | Box of 12 units (Ref. P736DRT5,580-2)”

Your email address will not be published. Required fields are marked *