We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Non-absorbable polypropylene suture Premisut Prime, double needle ⅜ circle trocar point 2xDRT17 mm, USP 4/0, blue thread 75 cm | Box of 12 units (Ref. P732DRT1740-2)

69,13 €

Non-absorbable polypropylene suture Premisut Prime in USP 4/0 gauge, presented with a double needle of ⅜ circle, cylindrical body and trocar point of 17 mm (2xDRT17 Prime profile). Blue monofilament thread, uncoated, 75 cm, with excellent glide, minimal tissue reaction and high tensile strength that is maintained for more than three months. Sterilised by ethylene oxide, single-use, in a box of 12 units with batch traceability. Ideal for approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery. Factory reference P732DRT1740-2 (SKU AMP732DRT1740-2).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP732DRT1740-2

Description

1. Commercial Introduction

The polypropylene suture Premisut Prime is the reference choice for surgery departments, purchasing centres and tenders looking for a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissues of moderate consistency with total control. This presentation in USP 4/0 gauge, with a double ⅜ circle needle and trocar point of 17 mm (profile 2xDRT17 Prime) and two 75 cm threads in blue, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.

It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available at Cahnos under the factory reference P732DRT1740-2 (SKU AMP732DRT1740-2), kept without altering characters.

2. Technical Explanation

Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wick effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.

The DRT 17 Prime needle (⅜ circle, cylindrical body with trocar point of 17 mm) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without cutting them: it passes through dense or slightly fibrous tissues with less resistance and without cutting effect on adjacent tissue, reducing trauma and bleeding. The double needle configuration allows continuous sutures or bilateral techniques without repositioning the needle in the needle holder. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Parameter Specification
Thread material Polypropylene monofilament, uncoated, dyed blue
Thread structure Non-grooved monofilament
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges
Thread length 2 threads of 75 cm (2 × 75 cm) per unit
Thread colour Identification blue
Needle shape ⅜ circular (3/8 circle)
Needle body Cylindrical
Tip type Trocar (Tapercut)
Needle size 17 mm (profile 2xDRT 17 Prime)
Configuration Double needle (2xDRT)
Manufacturing quality Prime (premium range)
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (individual sterile sachets)
Factory reference P732DRT1740-2
Reference Cahnos (SKU) AMP732DRT1740-2

DRT 17 family (⅜ circle trocar point) in USP 4/0 gauge:

Needle profile Presentation Reference
2xDRT 17 Prime 2 × 75 cm P732DRT1740-2 / AMP732DRT1740-2
2xDRT 17 Prime 2 × 90 cm P733DRT1740-2 / AMP733DRT1740-2
DRT 17 Prime 1 × 75 cm P732DRT1740 / AMP732DRT1740

4. Equivalences and Cross-References

The reference P732DRT1740-2 corresponds to the official nomenclature of the Premisut Prime range (profile 2xDRT 17 Prime, double thread of 75 cm). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Premisut Prime range (Cahnos) Polypropylene 2xDRT 17 Prime, USP 4/0, blue, 2 × 75 cm P732DRT1740-2 / AMP732DRT1740-2 Direct product reference Product analysed in this data sheet
Premisut Prime range (Cahnos) Polypropylene 2xDRT 17 Prime, USP 4/0, blue, 2 × 90 cm AMP733DRT1740-2 Configuration equivalent within the same system Same needle 2xDRT 17 and gauge USP 4/0; length changes to 2 threads of 90 cm
Ethicon (Johnson & Johnson MedTech) PROLENE® – blue monofilament polypropylene, USP 4/0, 90 cm, double needle V-4 of 17 mm 3/8 circle Tapercut 8925H Functional equivalence by specifications (no official cross-reference table) Matches in material, gauge, colour, double needle and needle geometry (17 mm, 3/8, trocar point). Length 90 cm vs 2 × 75 cm; presentation in box of 36 units; confirm batch and presentation against IFU
B. Braun Premilene® (blue monofilament polypropylene, USP 4/0, 75 cm, needle DRT 18) C2090320 / X2090320 Comparable by category / pending 1:1 confirmation Same blue polypropylene base, gauge and length (75 cm); needle of 17–18 mm but single needle and designation DRT 18; verify arc, point and number of needles in the manufacturer’s technical data sheet
Medtronic (Covidien) Surgipro™ II (polypropylene with polyethylene, blue monofilament) VP-521-X (USP 4/0) – confirm needle profile in tender Comparable by category / pending confirmation Copolymer with polyethylene; matches in gauge and needle family; verify exact measurement, number of needles and presentation against IFU
Serag-Wiessner SERAPREN® (blue monofilament polypropylene, metric 1.5 / USP 4/0) Profile 2x DR-17 – consult order code according to catalogue Comparable by category / pending confirmation Very close 2x DR-17 profile (double 17 mm trocar needle); confirm needle arc and official code with the distributor

Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ II or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.

5. Selection tips and variants of interest

  • Tissue to suture: the DRT needle with trocar point (Tapercut) is suitable for tissues of moderate consistency or slightly fibrous that require firm penetration with minimal aggression (skin, mucosa, subcutaneous tissue, ophthalmology and vascular planes). For very friable tissues consider conical point profiles (HR) from the same Premisut Prime range.
  • Needle size: the DRT of 17 mm is a medium-length needle, ideal for reduced surgical fields; for wider planes the DRT family of 25 mm is available in other gauges within the Premisut catalogue.
  • Gauge: USP 4/0 (metric 1.5) offers the balance between strength and manageability for fine tissues of moderate tension; for less demanding planes consider USP 5/0 (AMP732DRT1750-2) or, for greater support, USP 3/0 (AMP732DRT1730) with the same DRT 17 needle.
  • Presentation: the 2 × 90 cm version (AMP733DRT1740-2) provides greater useful length for continuous sutures, while the single needle version (AMP732DRT1740, 1 × 75 cm) reduces the cost per unit for occasional uses.
  • Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DRT1740-2 and the batch number for traceability in the operating theatre and in case of complaint.

Additional information

Material

Uncoated monofilament polypropylene

Structure

Non-grooved monofilament

Absorption

Non-absorbable (gradual encapsulation, support for more than 3 months)

USP size

4/0 (metric EP 1.5)

Needle body

Cylindrical

Needle size

17 mm (2xDRT 17 Prime)

Configuration

Double needle

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Use

Single-use, not re-sterilisable

Indications

Soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery

Manufacturer reference

P732DRT1740-2

Medida de aguja

2xDRT 17 prime

Usp

4/0

Color

Blue

Medida de hilo

2 × 75 cm, 75 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable polypropylene suture Premisut Prime, double needle ⅜ circle trocar point 2xDRT17 mm, USP 4/0, blue thread 75 cm | Box of 12 units (Ref. P732DRT1740-2)”

Your email address will not be published. Required fields are marked *