Description
1. Commercial Introduction
The Premisut Prime polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable suture with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissues of moderate consistency with total control. This presentation in USP 3/0 gauge, with ⅜ circle needle, cylindrical body and trocar point (tapercut) of 17 mm (DRT 17 Prime profile) and blue 75 cm suture, is indicated for approximation of soft tissues, ligatures and high-demand procedures in general surgery, cardiovascular surgery, ophthalmology and neurosurgery.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available from Cahnos with factory reference P732DRT1730 (SKU AMP732DRT1730), kept unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.
The DRT 17 Prime needle (⅜ circle, cylindrical body with Tapercut trocar point of 17 mm) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without sectioning them: it penetrates dense or slightly fibrous tissues with less resistance and without cutting effect on adjacent tissue, reducing trauma and bleeding. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 3/0 (metric EP 2.0 approx.); in accordance with USP and European Pharmacopoeia calibres |
| Thread length | 75 cm per unit |
| Thread colour | Identification blue |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), DRT profile |
| Needle size | 17 mm (DRT 17 Prime) |
| Configuration | Single needle (1 × DRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DRT1730 |
| Reference Cahnos (SKU) | AMP732DRT1730 |
DRT 17 family (⅜ circle, cylindrical body, trocar point) within the Premisut Prime range:
| Needle profile | USP size | Presentation | Reference Cahnos |
|---|---|---|---|
| DRT 17 Prime | 3/0 | 1 × 75 cm | AMP732DRT1730 (analysed product) |
| DRT 17 Prime | 4/0 | 1 × 75 cm | AMP732DRT1740 |
| DRT 17 Prime | 5/0 | 1 × 75 cm | AMP732DRT1750 |
| 2xDRT 17 Prime | 4/0 | 2 × 75 cm | AMP732DRT1740-2 |
| 2xDRT 17 Prime | 5/0 | 2 × 75 cm | AMP732DRT1750-2 |
| 2xDRT 17 Prime | 4/0 | 2 × 90 cm | AMP733DRT1740-2 |
| 2xDRT 26 Prime | 3/0 | 2 × 90 cm | AMP733DRT2630-2 |
| HRT 17 Prime (½ circle, trocar point) | 3/0 | 1 × 75 cm | AMP732HRT1730 |
| HR 17 Prime (½ circle, conical point) | 3/0 | 1 × 75 cm | AMP732HR1730 |
4. Equivalences and Cross-References
Reference P732DRT1730 corresponds to the official nomenclature of the Premisut Prime range (DRT 17 Prime profile, single needle, USP 3/0 gauge, 75 cm suture). Cahnos markets the product keeping the factory reference unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tender or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime range (Cahnos) | Polypropylene DRT 17 Prime, USP 3/0, blue, 75 cm | P732DRT1730 / AMP732DRT1730 | Direct product reference | Product analysed in this data sheet |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 3-0, V-4 TAPERCUT needle 17 mm ⅜ circle | 8926H (verified in Ethicon catalogue; double needle presentation, 90 cm, box of 36 units) | Functional equivalence by specifications (no official cross-reference table) | Matches in material, gauge, colour and needle geometry (17 mm, ⅜, trocar point); differs: double needle and 90 cm versus single needle of 75 cm and presentation of 12 units |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® 3-0 blue, 75 cm, pack of 12 units | W8549 (confirm needle with authorised distributor) | Comparable by category / pending 1:1 confirmation | Matches in calibre, length and colour; verify type, arc and exact needle measurement against IFU |
| B. Braun | Premilene® – blue polypropylene monofilament, 3/0, 75 cm, DRT18 needle | C2090321 (verified in distribution source; confirm with B. Braun) | Comparable by category / pending 1:1 confirmation | Same blue polypropylene base, gauge and length; needle designated DRT18 (≈17-18 mm) single needle; verify exact arc and point in the manufacturer’s technical data sheet |
| Medtronic (Covidien) | Surgipro™ II – polypropylene with polyethylene, blue monofilament, 3/0, 75 cm | VP-760-X (conical point CV-25, double armed) – confirm trocar profile in tender | Comparable by category, not interchangeable 1:1 | Copolymer with polyethylene and conical point (not trocar); verify needle geometry, number of needles and presentation against IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult order code according to calibre and needle | Pending confirmation | Non-absorbable polypropylene; confirm calibre, measurement and needle geometry with the distributor |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ II or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tender. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the DRT trocar-point (Tapercut) needle is suitable for tissues of moderate or slightly fibrous consistency requiring firm penetration with minimal trauma (skin, mucosa, subcutaneous tissue, vascular planes and ophthalmology). For very friable tissues, consider conical point (HR) profiles from the same Premisut Prime range.
- Needle size: the 17 mm DRT is a medium-length needle, ideal for reduced surgical fields; for wider planes, the DRT family of 26 mm in gauge 3/0 is available (AMP733DRT2630-2).
- Gauge: USP 3/0 offers the balance between strength and manageability for soft tissues and ligatures; for less demanding planes, consider USP 4/0 (AMP732DRT1740) or USP 5/0 (AMP732DRT1750) with the same DRT 17 needle.
- Configuration: if your protocol prefers suture with double needle (continuous or bilateral suturing techniques), the same family is available in 2xDRT 17 (AMP732DRT1740-2, AMP732DRT1750-2) and in double needle with 2 × 90 cm (AMP733DRT1740-2).
- Alternative curvature: for ½ circle arc with trocar point, reference AMP732HRT1730 is available; for conical point, AMP732HR1730.
- Sterility verification: product sterile by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DRT1730 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews