Description
1. Commercial Introduction
The polypropylene suture Premisut Prime in Long Pack format is the choice of professionals and purchasing centres looking for a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. This presentation incorporates a double ⅜ circle needle with extra smooth coronary trocar point (DCC) of 8 mm in VisiBlack technology (black needle), USP size 8/0 and 60 cm strands in high-visibility blue: a configuration of maximum fineness and contrast, designed for precision cardiovascular surgery on dense or calcified coronary bed, microsurgery, very delicate planes and precise ligatures.
It is supplied sterile, ready for single use, in Long Pack packaging (box of 12 units) with batch traceability, which facilitates hospital stock management and presentation to public tenders. Available at Cahnos under the factory reference P736DCC880-2VBLP (SKU AMP736DCC880-2VBLP), maintained without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) which, as an uncoated, non-braided monofilament, offers very smooth passage through tissue, without wicking effect, without promoting bacterial adherence and with minimal suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia sizes, and becomes gradually encapsulated, helping the wound for more than three months.
The DCC 8 mm Prime needle (⅜ circle, cylindrical body with extra smooth coronary trocar point, soft cutting edge coronary) is designed to penetrate dense, fibrous or calcified tissues, such as the calcified coronary bed, with controlled cutting and lower resistance to passage, minimising tissue damage and bleeding. VisiBlack technology (black needle) improves needle contrast in the surgical field, especially in the presence of blood or highly irrigated tissue. The double needle configuration allows continuous sutures, mattress stitches and bilateral anastomoses without repositioning the needle in the needle holder, optimising handling times. USP size 8/0 (EP metric 0.4) is one of the finest in the range, suitable for precision sutures on delicate structures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Factory reference | P736DCC880-2VBLP |
| Reference Cahnos (SKU) | AMP736DCC880-2VBLP |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-braided (without braiding) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 8/0 (metric EP 0.4); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.040 – 0.049 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 2 strands of 60 cm (2 × 60 cm) per unit |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Number of needles | 2 (double needle) |
| Needle curvature | ⅜ circle (3/8 circle), cylindrical body |
| Needle tip | Extra smooth coronary trocar (DCC), extra smooth coronary cutting (soft cutting edge coronary) |
| Needle size | 2 × DCC 8 mm (Prime quality) |
| Needle technology | VisiBlack: black needle for maximum visibility |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Soft tissue approximation, ligatures, cardiovascular surgery (calcified coronary), ophthalmology and neurosurgery |
| Commercial presentation | Long Pack, box of 12 sterile units; batch traceability |
Family Premisut Prime DCC VisiBlack / DCC in Long Pack:
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| 2xDCC 8 VisiBlack Prime | 8/0 | 2 × 60 cm | P736DCC880-2VBLP / AMP736DCC880-2VBLP (this product) |
| 2xDCC 9.3 Prime | 8/0 | 2 × 60 cm | P736DCC9,380-2LP / AMP736DCC9,380-2LP |
| 2xDCC 9.3 VisiBlack Prime | 7/0 | 2 × 75 cm | AMP732DCC9,370-2VBLP |
| 2xDCC 9.3 VisiBlack Prime | 6/0 | 2 × 75 cm | AMP732DCC9,360-2VBLP |
| 2xDCC 11 VisiBlack Prime | 6/0 | 2 × 60 cm | AMP736DCC1160-2VBLP |
4. Equivalences and Cross-References
The reference P736DCC880-2VBLP corresponds to the official nomenclature of the Premisut Prime range (profile 2xDCC 8 VisiBlack Prime, double 60 cm strand, USP size 8/0, black needle). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tendering or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 2xDCC 8 VisiBlack, USP 8/0, blue, 2 × 60 cm | P736DCC880-2VBLP / AMP736DCC880-2VBLP | Direct product reference | Product analysed in this data sheet; 2xDCC 8 mm VisiBlack needle, extra smooth coronary trocar point |
| Cahnos (Premisut Prime) | Polypropylene 2xDCC 9.3, USP 8/0, blue, 2 × 60 cm | AMP736DCC9,380-2LP | Direct range equivalent | Same size 8/0, colour and length; DCC 9.3 mm needle without VisiBlack technology (standard needle) |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 8/0, 60 cm, double BV175-7 needle of 8 mm, ⅜ circle taper point | 8767 | Functional equivalence by specifications (no official cross-reference table) | Code verified in official catalogue and authorised distribution: material, size 8/0, colour, double needle, 60 cm length and ⅜ 8 mm needle match; the point type differs (conical taper point versus extra smooth coronary VisiBlack trocar). Box of 12 units. Confirm batch and CE/MDR traceability against IFU |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 8/0, 60 cm, double BV175-6 MULTIPASS® needle of 8 mm, ⅜ circle taper point | 8741H / EPM8743 | Comparable by category, very close | Same material, size, colour, double needle and length; taper point (not coronary trocar) and non-darkened needle. Verify exact measurement and geometry against IFU |
| DemeTECH | DemeLENE® – blue polypropylene monofilament, 8-0, 60 cm (24″), double taper point needle ⅜ circle | PM69800.8G0P | Comparable by category (verify 1:1 in IFU) | Code verified in official DemeTECH store: material, size, colour, double needle and length match; taper point needle (DBV175-6) instead of extra smooth coronary trocar. Confirm CE marking/registration for use in the EU |
| B. Braun (Aesculap) | Premilene® / Optilene® – blue polypropylene monofilament | Code 8/0 · DCC8 not verified in this consultation | Comparable by category, not verified | Family confirmed in blue monofilament polypropylene; no exact reference 8/0 · double trocar needle of 8 mm · 60 cm has been located in official sources. Confirm with official catalogue before use. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer | Code 8/0 not verified | Not verified | Copolymer material (not pure polypropylene); pending confirmation of reference and needle geometry against IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer for this reference; comparisons with PROLENE®, DemeLENE®, Premilene®/Optilene® or Surgipro™ are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering. This needle geometry (2xDCC 8 VisiBlack, USP 8/0, 2 × 60 cm) is only fully safely interchangeable within the Premisut system itself. Consult the technical department at Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the USP 8/0 gauge (metric 0.4) is of maximum fineness, indicated for microsurgery, delicate vascular planes and precision sutures in ophthalmology and neurosurgery.
- Needle point: the extra-smooth coronary trocar point (DCC) is the choice for dense, fibrous or calcified tissues (calcified coronary bed); if the tissue is friable or very lax, consider taperpoint conical point profiles (DR) from the same Premisut range.
- Needle size: the 8 mm DCC is extremely compact, designed for reduced access fields and maximum precision. If the protocol requires greater travel, DCC 9.3 mm (2 × 75 cm in 6/0 and 7/0) and DCC 11 mm (2 × 60 cm in 6/0) are available within the VisiBlack family.
- VisiBlack technology: the black needle improves contrast in fields with bleeding or highly irrigated tissue; if you do not require a darkened needle, the 2xDCC 9.3 Prime variant in 8/0 and 60 cm (AMP736DCC9,380-2LP) covers the same gauge.
- Double needle: the 2 × 60 cm configuration reduces packaging opening per procedure, facilitates continuous sutures and bilateral techniques without repositioning the needle in the needle holder.
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P736DCC880-2VBLP and the batch number for traceability in the operating theatre.





Reviews
There are no reviews yet.