Description
1. Commercial Introduction
The polypropylene suture Premisut Prime in double-needle Long Pack format is the choice of the professional seeking a non-absorbable, durable closure with minimal tissue reaction in the most demanding procedures. Made from high-purity polypropylene monofilament, uncoated and smooth, it combines smooth, consistent glide with excellent handling, reducing surgical trauma and wicking effect.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied in a box of 12 sterile units with full batch traceability. Factory reference P736DCC1160-2LP (SKU Cahnos AMP736DCC1160-2LP).
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertia which, in monofilament form, behaves as an inert thread with a smooth surface: it has no wicking effect, is not degraded by hydrolysis or tissue enzymes, and gradually encapsulates in tissue, maintaining wound support for more than three months thanks to sustained high tensile strength. Its low memory and stable knot facilitate reliable approximation of soft tissues.
The ⅜ circular needle with cylindrical body and extra-smooth coronary trocar point (designation DCC, Prime quality) is designed to penetrate dense, fibrous or calcified tissues —such as the calcified coronary bed— with controlled cutting and reduced resistance to passage, minimising tissue damage. The double-needle configuration (2xDCC11) optimises material utilisation and facilitates continuous suturing and anastomosis techniques without rethreading, reducing handling times and contamination risk. USP 6/0 gauge is ideal for fine vascular anastomoses and precision ligatures.
The product is single-use, sterilised by ethylene oxide (EtO) and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Manufacturer reference | P736DCC1160-2LP |
| SKU Cahnos | AMP736DCC1160-2LP |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament (isotactic polymer), uncoated, dyed blue |
| Thread structure | Monofilament, non-channeled |
| USP size | 6/0 (metric 0.7) |
| Approximate thread diameter | 0.070 – 0.099 mm (indicative according to USP Pharmacopoeia) |
| Thread length | 60 cm (double needle on the same strand) |
| Colour | Identification blue |
| Number of needles | 2 (double needle) |
| Needle curvature | ⅜ circle (3/8), cylindrical body |
| Needle tip | Extra soft coronary trocar (DCC) |
| Needle size | 2 × DCC 11 mm (Prime quality) |
| Absorption | Non-absorbable; gradual encapsulation |
| Sterilisation | Ethylene oxide (EtO), single-use |
| Presentation | Long Pack, box of 12 sterile units |
3.2. Mechanical behaviour and clinical use
| Parameter | Value |
|---|---|
| Tensile strength retention | Maintained for more than 3 months (non-absorbable) |
| Tissue reaction | Minimal (inert material) |
| Sliding | Smooth and consistent, non-grooved |
| Main indications | Approximation of soft tissues, surgical ligatures, cardiovascular surgery (including calcified coronary), ophthalmology and neurosurgery |
3.3. Family Premisut Prime DCC in Long Pack (3/8 circle, extra smooth coronary trocar point)
| Needle profile | USP size | Thread | Reference Cahnos |
|---|---|---|---|
| 2×DCC 11 mm Prime | 6/0 | 2 × 60 cm | AMP736DCC1160-2LP (this product) |
| 2×DCC 11 mm Prime VisiBlack | 6/0 | 2 × 60 cm | AMP736DCC1160-2VBLP |
| 2×DCC 13 mm Prime | 6/0 | 2 × 45 cm | AMP731DCC1360-2LP |
| 2×DCC 13 mm Prime | 6/0 | 2 × 75 cm | AMP732DCC1360-2LP |
| DCC 13 mm Prime (single needle) | 6/0 | 1 × 75 cm | AMP732DCC1360LP |
| 2×DCC 13 mm Prime | 5/0 | 2 × 75 cm | AMP732DCC1350-2LP |
| 2×DCC 13 mm Prime | 5/0 | 2 × 90 cm | AMP733DCC1350-2LP |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the Premisut manufacturer cross-referencing this reference with other brands. The references indicated below are considered comparable at category level (non-absorbable polypropylene monofilament suture, blue colour, USP 6/0 gauge and ⅜ circle needle), not interchangeable 1:1. Before substitution in tenders or closed clinical protocols, the needle point type (extra-smooth coronary trocar vs. standard trocar vs. conical), number of needles, needle size and presentation must be verified in each brand’s technical data sheet or IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polypropylene 3/8 extra smooth coronary trocar point 2×DCC11 | P736DCC1160-2LP / AMP736DCC1160-2LP | Original reference | Double needle 3/8 extra smooth coronary trocar 11 mm, USP 6/0, blue, 60 cm, Long Pack, box of 12 units. |
| Premisut Prime (Cahnos) | Polypropylene 2×DCC11 VisiBlack, USP 6/0, blue, 60 cm | AMP736DCC1160-2VBLP | Direct range equivalent | Same geometry, gauge and length; black VisiBlack needle with high visibility instead of standard needle (silver). |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, 6-0, double needle CC-11 MULTIPASS® TAPERCUT 11 mm, 3/8, 60 cm | W8802 | Functional category equivalence (very close) | Code verified in Ethicon catalogue and authorised distributors: material, gauge, colour, double 11 mm needle, 3/8 circle and 60 cm length match. Key difference: TAPERCUT CC point (conical body with cutting point) versus extra-smooth coronary trocar DCC. Box of 12 units. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, 6-0, double needle C-1 3/8 taper point 13 mm, 45 cm | M8718 / 8718H | Functional equivalence by category | Same gauge, double 3/8 needle and blue monofilament thread, but conical point (taper point) of 13 mm and length of 45 cm versus 60 cm. Verified in Ethicon catalogue and GUDID. |
| Vitrex Medical (Chiralen) | Chiralen blue monofilament polypropylene, DRT13, 3/8 trocar, 6/0, 75 cm | 4022PP 5309 | Functional category equivalence (very close) | Code verified in authorised distributor (DH Medical): same 6/0 gauge, 3/8 trocar needle and blue monofilament thread, but standard trocar point (not extra-smooth coronary), 13 mm needle and 75 cm versus 60 cm; box of 24 units. Verify CE certificate. |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 6-0, double needle DR13/DR13, 3/8 taper point, 75 cm | C2095906 | Comparable by category | Same gauge, double 3/8 needle and blue thread, but conical point (taper point) instead of extra-smooth coronary trocar, 13 mm needle and 75 cm versus 60 cm; box of 36 units. |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene/polyethylene copolymer, 6-0, CV-11 3/8 taper point needle, 60 cm | VP726X | Comparable by category | Same gauge, CV-11 3/8 needle and 60 cm blue thread, but conical point (taper point) and polypropylene/polyethylene copolymer material (not pure polypropylene); presentation in box of 36 units. |
Note: references from other manufacturers must always be checked against their official source (technical data sheet, IFU, manufacturer’s catalogue, GUDID/FDA or EUDAMED). There is no equivalence table validated by the manufacturer; consult the Cahnos technical department before use in tenders.
5. Selection tips and variants of interest
To choose the appropriate suture, always verify: USP gauge, thread length, needle curvature and size, point type (conical, standard trocar, extra-smooth coronary trocar or cutting), material, colour and presentation. The extra-smooth coronary trocar point (DCC) is especially indicated in dense tissues and calcified coronary bed; if the tissue is very friable or the lumen is small, consider the conical point (taper point) version from the same Premisut family.
Variants of interest in the Cahnos catalogue: the version with high-visibility black VisiBlack needle (AMP736DCC1160-2VBLP) facilitates contrast in bleeding fields; in DCC 13 mm needle it offers AMP731DCC1360-2LP (2×45 cm), AMP732DCC1360-2LP (2×75 cm) and AMP732DCC1360LP (single needle 1×75 cm); for 5/0 gauge consult AMP732DCC1350-2LP (2×75 cm) and AMP733DCC1350-2LP (2×90 cm). Unifying supplier across the entire permanent suture portfolio enables B2B volume conditions.
Store the product in its sterile packaging, in a cool, dry place, protected from direct sunlight, and check the expiry date and blister integrity before each use. For annual contracts, tenders or hospital supply agreements, contact the Cahnos technical-commercial team.





Reviews
There are no reviews yet.