Description
1. Product Presentation
The polypropylene suture Premisut Prime in USP 0 gauge and double presentation (2×75 cm) is the reference solution for surgical services, purchasing centres and tenders that need a non-absorbable monofilament with predictable behaviour, excellent handling and minimal tissue reaction. Its ⅜ circle needle of 24 mm with triangular reverse cutting grooved point (DS24 Prime profile) ensures firm and controlled penetration in soft tissues and skin planes, while the high-visibility blue thread ensures safe handling and reliable knotting in every procedure.
Each unit is supplied sterile, ready for immediate use, in a box of 12 individual sachets with batch traceability, which facilitates hospital stock management and submission to public tender. Available under the factory reference P732DS2410.2 (SKU Cahnos AMP732DS2410.2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament. Lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ⅜ circle needle with triangular reverse cutting point (reverse cutting) places the cutting edge on the outer face of the curve, allowing it to pass through firm, non-distensible tissues (skin, fascia, subcutaneous) with a clean, stable cut, minimising the risk of tearing. The Prime finish provides a grooved needle body with improved penetration and a more resistant tip compared to standard quality, and the grooved blue thread facilitates smooth, consistent delivery during knotting. Product sterile by ethylene oxide, single-use and non-reesterilizable.
3. Technical Specifications
3.1. General characteristics of the reference
| Characteristic | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 0 (metric 3.5) |
| Thread length | 2 × 75 cm (2 threads per unit, double format) |
| Thread colour | Blue identifier, grooved surface (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point (reverse cutting), grooved, DS profile |
| Needle size | DS24 (24 mm) Prime |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS2410.2 |
| Reference Cahnos (SKU) | AMP732DS2410.2 |
3.2. Premisut Prime DS24 range (⅜ circle needle, triangular reverse cutting grooved point, blue, 75 cm)
| USP size | Presentation | Factory reference | SKU Cahnos |
| 4/0 | 1 × 75 cm | P732DS2440 | AMP732DS2440 |
| 3/0 | 2 × 75 cm | P732DS2430.2 | AMP732DS2430.2 |
| 2/0 | 2 × 75 cm | P732DS2420.2 | AMP732DS2420.2 |
| 0 | 2 × 75 cm | P732DS2410.2 | AMP732DS2410.2 (this product) |
| 1 | 2 × 75 cm | P732DS2401.2 | AMP732DS2401.2 |
4. Equivalences and Cross-References
Important: there is no equivalence table validated by the manufacturer that cross-references this product with other brands; consult the technical department before using in tenders or direct substitution. The comparisons indicated are functional, at category level, and not interchangeable 1:1; they must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS24, USP 0, blue, 75 cm (single thread) | AMP732DS2410 (Ref. P732DS2410) | Direct equivalent within the catalogue (1-thread configuration) | Same DS24 needle, same gauge, colour and material; the number of threads per pack changes (1 vs 2). |
| Cahnos (Premisut standard) | Polypropylene 3/8 DS24, USP 0, blue, 75 cm | AM732DS2410 (Ref. 732DS2410) | Direct equivalent within the catalogue (standard quality) | Same needle geometry and gauge; the Prime finish (grooved needle with improved penetration) and the number of threads vary. |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, USP 0, 75 cm, CP-1 reverse cutting needle | F2825 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: material, gauge, colour and length match; CP-1 needle of smaller size than DS24 (24 mm); pack of 36 units. |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, USP 0, 75 cm, FSLX 3/8 reverse cutting needle | 8690H | Comparable by category, not interchangeable 1:1 | Same material, gauge, colour and length; FSLX needle of 36 mm compared to the DS24 of 24 mm. |
| B. Braun (Aesculap) | Optilene® – polypropylene monofilament with polyethylene, blue, DS24 reverse cutting needle | RCPC3090236 (verified in 2/0; confirm for USP 0) | Pending confirmation | DS24 needle geometry very close; copolymer composition (not pure polypropylene). Verify gauge and pack in official catalogue. |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament, DS reverse-cutting needle | CO203415 (verified in 3/0, DS-25); consult USP 0 code | Pending confirmation | Family with same indication; DS-25 needle (25 mm) very close to DS24. Confirm gauge, size and presentation. |
| Medtronic / Covidien | Surgipro™ II – polypropylene copolymer with polyethylene, CT25 needle (25 mm) | PP44620 (gauge 2/0) | Comparable by category, not interchangeable 1:1 | Copolymer material and 25 mm needle; reference of another gauge; validate USP 0 and geometry against the IFU. |
5. Selection tips and variants of interest
Number of threads: the double presentation 2×75 cm is indicated for high-consumption procedures or when two identical strands are required per pack opening; if the protocol prefers a single thread, request the AMP732DS2410 version (1×75 cm, same DS24 and USP 0 gauge).
Gauge: USP 0 (metric 3.5) offers an optimal balance between fineness and tensile strength, suitable for soft tissues and medium-high tension ligatures. With the same DS24 Prime needle, it is available in USP 4/0 (AMP732DS2440), 3/0 (AMP732DS2430.2), 2/0 (AMP732DS2420.2) and USP 1 (AMP732DS2401.2) for greater mechanical demand.
Needle size: the DS24 of 24 mm is a medium-length needle, suitable for superficial planes and areas with limited access; for larger fields consider the DS30 or DS36 in the same family. The Prime quality provides a grooved-body needle with improved penetration, an advantage in fibrous tissues and high-precision procedures.
Pre-substitution verification: always check curvature (⅜ circle), needle length (24 mm), point type (triangular reverse cutting, not to be confused with conical point), USP 0 gauge and number of threads per pack before approving any change of supplier or reference.
Sterility and traceability: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS2410.2 and the batch number for traceability in the operating theatre.





Reviews