Description
1. Product Presentation
The polypropylene suture PREMISUT PRIME we offer at Cahnos is the reference solution for professionals who need a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with a fluted reverse cutting triangular point of 36 mm (model DS36), gauge USP 1 (metric 4), high-visibility blue thread and two 75 cm strands per pack, which optimises performance in the operating theatre, in purchasing departments and in tenders. Sterile product by ethylene oxide, single-use, presented in a box of 12 units with full batch traceability.
2. Technical explanation
Polypropylene is a linear synthetic polymer (polyolefin) extruded in uncoated monofilament format. As it is non-absorbable, the thread does not degrade in the body: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase. It is therefore the classic choice in cardiovascular, vascular and long-term suture surgery.
The ⅜ circle needle with triangular reverse cutting point (reverse cutting) and fluted body penetrates firm, non-distensible tissues with a clean cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, reducing the risk of tearing in skin and soft tissues, while the fluted body facilitates passage through tissue, minimising trauma. The Prime finish provides a needle with improved penetration compared to the standard Premisut quality. The blue colour of the strand ensures optimal visibility on the surgical field and safe control during knotting.
3. Technical Specifications
| Characteristic | Specification |
| Brand / Line | Premisut Prime (polypropylene) |
| Material | Polypropylene monofilament, uncoated, dyed blue |
| Structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Thread colour | Fluted blue (high visibility) |
| Gauge | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle tip | Reverse cutting triangular (reverse cutting), grooved body |
| Needle size | 36 mm (model DS36 Prime) |
| Number of threads | 2 |
| Thread length | 2 × 75 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS3601.2 |
| Reference Cahnos (SKU) | AMP732DS3601.2 |
4. Equivalences and Cross-References
Non-absorbable polypropylene monofilament is one of the most widespread permanent suture families in the surgical market. The reference commercial ranges are PROLENE® (Ethicon / Johnson & Johnson), Premilene® (B. Braun) and Surgipro™ II (Medtronic / Covidien). Within Cahnos’s own catalogue there are references of the same Premisut family with equivalent or comparable configuration:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS36, USP 1, blue, 2×75 cm | AMP732DS3601.2 (Ref. P732DS3601.2) | Direct reference | Product described in this data sheet |
| Cahnos (Premisut) | Polypropylene 3/8 DS36, USP 1, blue, 75 cm | AM732DS3601 (Ref. 732DS3601) | Direct range equivalent (varies in number of threads and quality) | Same DS36 needle, same gauge and colour; standard quality with 1 thread of 75 cm instead of 2 |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS36, USP 0, blue, 2×75 cm | AMP732DS3610.2 (Ref. P732DS3610.2) | Comparable by category | Same DS36 needle and double presentation; USP 0 gauge of smaller diameter |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS45, USP 1, blue, 2×90 cm | AMP733DS4501.2 (Ref. P733DS4501.2) | Comparable by category | Same double presentation and gauge; DS45 needle of 45 mm versus DS36 of 36 mm |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, USP 1, 75 cm | 8425H (CT-1 needle, ½ circle, 36.4 mm) | Comparable by category, not interchangeable 1:1 | Code verified in catalogue and distributors; needle geometry ½ circle (CT-1) different from the ⅜ reverse cutting DS36 |
| Ethicon (J&J MedTech) | PROLENE® – FSLX series ⅜ circle reverse cutting | 8690H (USP 0, FSLX 36 mm, 75 cm) · 8649H (3/0, FSLX 40 mm) | Comparable by category / pending confirmation | Series with ⅜ reverse cutting needle verified in other gauges; no public USP 1 code with FSLX 36 mm 75 cm was found: confirm with manufacturer |
| B. Braun | Premilene® – blue polypropylene monofilament, USP 1, 75 cm | C2090153 (PREMILENE 1 (4) 75CM HR37S) | Comparable by category, not interchangeable 1:1 | Same material, gauge and length; HR needle (½ circle) versus ⅜ reverse cutting DS36. Verify geometry in official catalogue |
| Medtronic / Covidien | Surgipro™ II – polypropylene/polyethylene, blue | PP44620 (2/0, CT25) · SP685 (2/0, C-15 ⅜ reverse cutting, 75 cm) | Comparable by category, not interchangeable 1:1 | Copolymer of polypropylene with polyethylene; gauge and needle different from the DS36 USP 1 configuration |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult code according to gauge and needle | Comparable by category | Blue non-absorbable polypropylene monofilament; verify gauge, needle geometry and lengths with the distributor. |
Technical note: there is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. Consult Cahnos’s technical department to validate any equivalence before use.
5. Selection tips and variants of interest
Number of threads: the double presentation 2 × 75 cm (AMP732DS3601.2) is indicated for surgeries that require multiple passes, thread removals or long sutures; if you prefer a single thread, the standard reference AM732DS3601 (1 × 75 cm) is available.
Gauge: USP 1 (metric 4) offers high tensile strength for deep planes, fasciae and tension ligatures; for tissues with lower resistance, the same DS36 needle is available in USP 0 (AMP732DS3610.2).
Needle size: the 36 mm DS36 is ideal for medium-hardness tissues and standard working fields; for deeper planes or thick tissues consider the DS45 (AMP733DS4501.2) and for reduced fields the DS30, DS24 or DS19 variants of the same Premisut Prime family.
Prime quality: the Prime range offers a fluted-body needle with improved penetration and a more resistant tip compared to the standard Premisut line, an advantage in fibrous tissues.
Traceability: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS3601.2 and the batch number for traceability in the operating theatre.





Reviews
There are no reviews yet.